A-Series, Thin Film Membrane (TFM*)
Typical Operating Pressure
200-500psi (1,379-3,447kPa)
Maximum Operating Pressure
Maximum Permeate Pressure2
Recommended Pressure Drop
Over an element: 12psi (83kPa)
Over an element: 15psi (103kPa)
Per housing: 60psi (414kPa)
1000ppm-hours
dechlorination recommended
Polisher RO
Permeate & Condensate Polishing
The Polisher RO family of proprietary thin film reverse osmosis membrane elements is characterized
by high flux and excellent sodium chloride rejection.
The membrane has an average rejection of 99.5%
on 2,000ppm NaCl at 25°C (77°F) and 225psi operating pressure.
The Polisher RO elements provide high rejection of
dissolved solids and low molecular weight organic
constituents at operating pressures up to 600psi.
Typically used in food-related processing that requires stringent sanitary procedures, the RO Polisher is used to treat evaporator condensate (cow
water) and RO/NF permeate in order to recover
process water for the plant.
The Polisher RO element features a Durasan* Cage
patented outer wrap, standard feed spacer and
polysulfone parts.
Table 1: Element Specification
Table 2: Dimensions and Weight
1
These elements are dried and bagged before shipping.
2
Internal diameter.
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Others pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Table 3: Operating parameters
Figure 1: Element Dimensions Diagram
1
Clean water flux (CWF) is the rate of water permeability through the membrane
after cleaning (CIP) at reproducible temperature and pressure. It is important to
monitor CWF after each cleaning cycle to determine if the system is being
cleaned effectively. CWF can vary ±25%.
2
Permeate pressure should never exceed the concentrate pressure.