GE P&W Polisher RO User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Membrane
A-Series, Thin Film Membrane (TFM*)
Model
Spacer
mil (mm)
Active area
ft2 (m2)
Part
number
POLISHER RO8040C30
30 (0.76)
404 (37.5)
1206650
Model1
Dimensions, inches (cm)
Boxed
A
B2
C
Weight lbs (kg)
POLISHER RO8040C30
40.00
(101.6)
1.125 (2.86)
7.913
(20.1)
29
(13.2)
Typical Operating Pressure
200-500psi (1,379-3,447kPa)
Typical Operating Flux
15-20 GFD (25-34 LMH)
Maximum Operating Pressure
600psi (4,137kPa)
Maximum Permeate Pressure2
60 psi (413 kPa)
Maximum Temperature
122°F (50°C)
pH Range
2.0-11.0
Recommended Pressure Drop
Over an element: 12psi (83kPa)
Maximum Pressure Drop
Over an element: 15psi (103kPa) Per housing: 60psi (414kPa)
Chlorine Tolerance
1000ppm-hours dechlorination recommended
Temperature
pH minimum
pH maximum
50°C (122°F)
2.0
11.5
45°C (113°F)
1.5
11.5
35°C (95°F)
1.5
11.5
25°C (77°F)
1.0
12.0
Polisher RO
Permeate & Condensate Polishing
The Polisher RO family of proprietary thin film re­verse osmosis membrane elements is characterized by high flux and excellent sodium chloride rejection. The membrane has an average rejection of 99.5% on 2,000ppm NaCl at 25°C (77°F) and 225psi oper­ating pressure.
The Polisher RO elements provide high rejection of dissolved solids and low molecular weight organic constituents at operating pressures up to 600psi. Typically used in food-related processing that re­quires stringent sanitary procedures, the RO Polish­er is used to treat evaporator condensate (cow water) and RO/NF permeate in order to recover process water for the plant.
The Polisher RO element features a Durasan* Cage patented outer wrap, standard feed spacer and polysulfone parts.
Table 1: Element Specification
Table 2: Dimensions and Weight
1
These elements are dried and bagged before shipping.
2
Internal diameter.
3
The element diameter (dimension C) is designed for optimum performance in GE pressure vessels. Others pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity.
Table 3: Operating parameters
Figure 1: Element Dimensions Diagram
1
Clean water flux (CWF) is the rate of water permeability through the membrane after cleaning (CIP) at reproducible temperature and pressure. It is important to monitor CWF after each cleaning cycle to determine if the system is being cleaned effectively. CWF can vary ±25%.
2
Permeate pressure should never exceed the concentrate pressure.
Table 4: CIP limits for RO elements
Loading...