GE P&W PAS6074 User Manual

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2011, General Electric Company. All rights reserved.
FSbSteamatePAS6074_EN.doc Apr-11
Steamate* PAS6074
Total Boiler System Corrosion Inhibitor
Unique blend of Polyamine and Neutralizing
amine corrosion inhibitors
Protects feedwater, boiler and steam conden-
sate system surfaces against both carbonic acid and dissolved oxygen corrosion
Provides effective coverage of the entire steam
boiler system from a single feedwater injection point
Reduces chemical inventory and simplifies
treatment program monitoring & control
Reduces total cost of ownership thru improved
corrosion control
Description and Use
Steamate* PAS6074 is a blend of a multifunctional, volatile, amine corrosion inhibitor (the “Polyamine” component), and a specific blend of neutralizing amines selected for effective coverage of complex steam distribution systems.
Steamate PAS6074 protects metal surfaces from corrosion via multiple mechanisms. The volatile Pol­yamine corrosion inhibitor forms a barrier film on all metal surfaces. Thus, the deaerator, feedwater pip­ing, boiler, steam piping and condensate return pip­ing are all protected from oxygen and carbonic acid corrosion. The product also contains a blend of neutralizing amines, which can neutralize acidic contaminants and elevate the pH of the condensate into the mildly alkaline range, where the protective metal oxides are most stable and adherent.
Improved corrosion control reduces the potential for boiler tube failures by reducing the level of corrosion product ingress from the steam condensate and
feedwater circuits, and the resulting metal oxide
deposition on internal boiler heat transfer surfac­es. It also maintains optimum fuel-to-steam effi­ciency by maintaining clean heat transfer surfaces, and minimizes disruptive outages and maintenance costs associated with corrosion­related failures of steam condensate and feedwa­ter piping, economizers, condensers and other heat exchangers, steam traps and other associat­ed equipment.
Typical Applications
Steamate PAS6074 is designed for application to steam boilers. This technology is not approved for use where the steam contacts food products or is used for direct humidification of indoor air.
Treatment and Feeding Requirements
Feed Point – Steamate PAS6074 is designed to be
fed neat (undiluted) into the storage section of the deaerator below the waterline.
Feedrate – Use in accordance with control proce- dures GE establishes for a specific system. The range of application is between 2 and 20 ppm (mg/L) as Steamate PAS6074 to the feedwater.
Dilution Steamate PAS6074 should be fed neat directly out of the shipping container. It is not de­signed for dilution or blending with other treat­ment products.
Physical and Chemical Properties
Physical and chemical properties are shown on the Material Safety Data Sheet, a copy of which is available on request.
Packaging Information
Steamate PAS6074 is a liquid blend supplied in a variety of consumer packages.
Storage
Store Steamate PAS6074 at moderate temperatures (45 to 100°F, 7 to 38°C) in a ventilated location and protect from freezing.
Safety Precautions
A Material Safety Data Sheet containing detailed information about this product is available on re­quest.