GE P&W OSMO BEV NF User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Membrane
Cellulose Acetate
Model
Average
permeate flow
gpd (m3/day)
1,2
Average MgSO4
rejection
1,2
Average NaCl
rejection1
OSMO-BEV-NF-FF
8,200 (31.0)
97.0%
60%
Model
Active area
ft2 (m2)
Outer wrap
Part
number
OSMO-BEV-NF-FF
336 (31.2)
Full-Fit*
1233033
Model1
Dimensions, inches (cm)
Boxed
A
B2
C3
Weight
lbs (kg)
OSMO-BEV-NF-FF
40.0
(101.6)
1.125 (2.86)
7.9
(20.1)
32
(14.5)
OSMO* BEV NF Series

Beverage and Bottled Water Production

The OSMO* BEV NF membrane element is engi­neered to provide beverage plants with consistent, high quality water for production of carbonated soft drinks, juices, and sport drinks. The OSMO BEV NF element will process most municipal or plant well­water to meet your alkalinity, hardness and low so­dium requirements. The OSMO BEV NF membrane element is chlorine tolerant, and offers a salt pas­sage profile that permits maximum water recovery by the NF.
The OSMO BEV NF membrane element is tested and certified by NSF International against NSF/ANSI Standard 61 for material requirements only.
Features include a Full-Fit* design that eliminates the stagnant zone associated with industrial FRP elements and their brine seals, which can act as a site for bacterial growth. The OSMO BEV NF element forms a flush-fit with the inner diameter of the membrane element housing, creating a self­cleaning effect. This design also offers less pressure resistance than an industrial FRP element, resulting in lower brake horsepower and substantial energy savings.
The OSMO BEV NF membrane is following a 100% Wet Test Quality Assurance.
Table 1: Element Specification
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
2
Testing conditions: 2,000ppm MgSO4 solution at 225psi (1,551kPa) operating
pressure, 77 °F, pH 6.5 and 15% recovery.
Figure 1: Element Dimensions Diagram – Female
Table 2: Dimensions and Weight
Figure 1: High Flow Rate at Low Pressure Drop.
1
These elements are dried then bagged before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE Water & Process Technologies pressure vessels. Others pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity.
Typical Operating Pressure
60-200psi (413.7 - 1,379kPa)
Typical Operating Flux
10-20GFD (15-35LMH)
Maximum Operating Pressure
450psi (3,102kPa)
Maximum Temperature
Continuous Operation: 86°F (30°C) Clean-In-Place (CIP): 86°F (30°C)
Minimum Crossflow
30gpm (6.8 m3/hr)
pH Range
Continuous Operation: 5.0-6.5 Clean-In-Place (CIP): 3.0-8.0
Maximum Pressure Drop
Over an element: 12psi (83kPa) Per housing: 50psi (345kPa)
Chlorine Tolerance
1ppm maximum continuous 30ppm for 30 min. during sanitization
Feedwater
NTU < 1 SDI < 5
Table 3: Operating and CIP parameters
Page 2 FS1277EN
Loading...