M-series, polyacrylonitrile
Maximum Operating Pressure
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
Continuous operation:: 2-10,
Clean-In-Place (CIP): 3-9
Over an element: 15psi (103kPa)
Per housing: 60psi (414kPa)
MW Series
Industrial Oil/Water Separation UF Elements
The M-Series Ultrafillic* membranes are made of
polyacrylonitrile (PAN) polymer. This membrane is
characterized by a pore size of 0.01 microns with an
approximate molecular weight cut-off of 20K-50K
Dalton. To avoid fouling by "free" oils, the MW –
series elements have been engineered to be extremely hydrophilic (water attracting) as compared
to conventional membranes that are oleophilic (oil
attracting).
MW Elements are used for oil/water separation and
suspended solids removal. They are also used as
pretreatment of process water before reverse osmosis or nanofiltration.
Figure 2: Element Dimensions Diagram, Male 2540 & 4040
Table 2: Dimensions and Weight
Table 1: Element Specification
Figure 1: Element Dimensions Diagram, Female 8040
1
Internal diameter unless specified OD (outside diameter).
²These elements are bagged dry before shipping.
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Others pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
* Element sized 8040 can be used at higher temperature. Please contact your GE
representative for further technical recommendations.
Note: Oil/water separation applications require the selection of materials compatible with the content of the highly concentrated solution.