GE P&W MW User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us” .
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Membrane
M-series, polyacrylonitrile
Model
Spacer
mil (mm)
Active area
ft2 (m2)
Outer wrap
Part
number
MW2540F30
30 (0.76)
23 (2.1)
Fiberglass
1233383
MW4040F50
50 (1.27)
65 (6.0)
Fiberglass
3050562
MW8040C50
50 (1.27)
266 (24.7)
Cage
1220654
MW8040F50
50 (1.27)
261 (24.2)
Fiberglass
1229852
Model²
Dimensions, inches (cm)
Boxed
A
B1
C3
Weight lbs (kg)
MW2540F30
40.0
(101.6)
0.75
(1.9) OD
2.4
(6.1)
4
(1.8)
MW4040F50
40.0
(101.6)
0.75
(1.9) OD
3.9
(9.9) 9 (4.1)
MW8040C50
40.0
(101.6)
1.125 (2.86)
7.9
(20.1)
29
(13.2)
MW8040C50
40.0
(101.6)
1.125 (2.86)
7.9
(20.1)
29
(13.2)
Typical Operating Flux
5 - 20 GFD (8 – 34 LMH)
Maximum Operating Pressure
100psi (700kPa)
Maximum Temperature*
Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C)
pH Range
Continuous operation:: 2-10, Clean-In-Place (CIP): 3-9
Maximum Pressure Drop
Over an element: 15psi (103kPa) Per housing: 60psi (414kPa)
Chlorine Tolerance
200,000 ppm-hours
MW Series

Industrial Oil/Water Separation UF Elements

The M-Series Ultrafillic* membranes are made of polyacrylonitrile (PAN) polymer. This membrane is characterized by a pore size of 0.01 microns with an approximate molecular weight cut-off of 20K-50K Dalton. To avoid fouling by "free" oils, the MW – series elements have been engineered to be ex­tremely hydrophilic (water attracting) as compared to conventional membranes that are oleophilic (oil attracting).
MW Elements are used for oil/water separation and suspended solids removal. They are also used as pretreatment of process water before reverse os­mosis or nanofiltration.
Figure 2: Element Dimensions Diagram, Male 2540 & 4040
Table 2: Dimensions and Weight
Table 1: Element Specification
Figure 1: Element Dimensions Diagram, Female 8040
1
Internal diameter unless specified OD (outside diameter).
²These elements are bagged dry before shipping.
3
The element diameter (dimension C) is designed for optimum performance in GE pressure vessels. Others pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
* Element sized 8040 can be used at higher temperature. Please contact your GE representative for further technical recommendations.
Note: Oil/water separation applications require the selec­tion of materials compatible with the content of the high­ly concentrated solution.