Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1275EN.doc Jul-13
Thin-Film Membrane (TFM*)
Average
permeate
flow gpd
(m3/day)
1,2
Average
NaCl re-
jection
1,2
Minimum
NaCl re-
jection
1,2
MUNI RO LE Series
Membrane Elements for Municipal Drinking Water Plants
Engineered to treat municipal potable water at lower pressures, the MUNI RO LE series enables drinking water processes to achieve reduced operating
costs. Low-pressure operations also reduce membrane compaction, which increases the efficiency of
the RO system.
Description and Use
The MUNI RO LE series offers the unique solutionoriented option of a 400 sq. ft. Full-Fit* membrane
element. The creative Full-Fit design forms a close
fit within the pressure vessel walls, thus eliminating
dead spaces prone to bacterial growth and adhesion, and allowing for quick and complete cleaning.
In addition to this sanitizing feature, pressure drop
across the elements using Full-Fit design is significantly less than standard FRP construction (Figure
1), which may lead to substantial energy savings.
Figure 1: High Flow Rate at Low Pressure Drop
Table 1: Element Specification
The MUNI RO LE membrane elements are tested
and certified by NSF international against NSF/ANSI
Standard 61 for material requirements only.
The MUNI RO LE membrane is a low energy element
following a 100% Wet Test Quality Assurance.
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
2
Testing conditions: 500ppm NaCl solution at 115psi (792.9kPa) operating pres-
sure, 77°F (25°C), pH 7.5 and 15% recovery.
Typical Operating Pressure
Maximum Operating
Pressure
Continuous operation: 112°F
(50°C)
Clean-In-Place (CIP): 112°F (50°C)
Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Over an element: 12psi (83kPa)
Per housing: 50psi (345kPa)
1,000+ ppm-hours,
dechlorination recommended,
Recommended single element recovery
Figure 2: Element Dimensions Diagram – Female
Table 2: Dimensions and Weight
1
These elements are bagged wet before shipping.
2
Internal diameter.
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Others pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
Page 2 FS1275EN