GE P&W Leakwise Oil-on-Water Monitoring &Detection User Manual

GE Power & Water
Water & Process Technologies
Analytical Instruments
Leakwise Oil-on-Water Detection and Monitoring Systems
For the reliable detection, monitoring, measurement, alerting, and control of hydrocarbons on water
Fact Sheet
What Leakwise Does for You
• Provides early warning by continuous, on-line detection of hydrocarbons on water starting at 0.3 mm
• Monitors buildup of hydrocarbons on water
• Provides linear measurement of hydrocarbon layers in the range of 1–200 mm or greater
• Installs easily
• Operates virtually maintenance-free over extended periods of time
• Ensures reliable detection, regardless of:
- Coating of sensor with dirt or oil
- Changes in water salinity or temperature
- Variations in water table
• Conforms to EPA regulations
• Certified for operation in hazardous areas
• Specifications and performance tested and approved by the German TÜV
• Offers convenient, user-adjustable set points of “Low Oil” and “High Oil” for alarm and control
• Displays processor output with two relays and four indicator lights (water/air/oil/ sensor disconnect); optional outputs include 4-20 mA, RS-232/RS-422, a bar graph, and audio alarm
• Sends alarm and status messages via PTP radio or cellular communication with optional wireless sensor
Leakwise is the most versatile and reliable sen­sor system available for oil-on-water detection and monitoring. The Leakwise system can help you avoid expensive downtime, regulatory fines, and cleanup costs by:
• Detecting the presence of any type of
hydrocarbon on water immediately
• Monitoring the buildup of hydrocarbons
on water
• Measuring hydrocarbon layer thickness
with accuracy in the range of 1–200 mm or greater
• Alerting facility operators of oil presence
or thickness with visual or audible alarms and messages
• Controlling skimmers, discharge pumps,
and shutoff or diverter valves with a remote or local relay contact
System Components
A Leakwise system con­sists of a wired or wire­less signal processor and one or more sensors, depending on your appli­cation needs. The intrin-
sically safe sensors work in virtually any type of water. They continue to work even when coated with dirt or oil, thus eliminating false alarms. In fact, Leakwise sensors are designed to perform for years, maintenance­free, without parts replacement.
World Class Technology
The Leakwise sensors use a patented, high­frequency Electromagnetic Absorption Technique. Each floating sensor houses a high-frequency electromagnetic energy transmitter and a receiving antenna which continuously monitor the liquid surface.
Since water absorbs more electromagnetic energy than hydrocarbons, changes in the absorption rate of water indicate the pres­ence or buildup of hydrocarbons.
The Leakwise sensors not only enable reliable detection of hydrocarbons, but also provide valid indications of the thickness of the hydro­carbon layers and the percent of water in oily emulsions.
The Leakwise sensors can be used to detect the interface between any two immiscible liq­uids with different absorption rates. No other oil sheen monitoring system does this.
Leakwise Provides Reliable, Early Detection of Oil Leaks or Spills
Processor
Sensor
Industries and Applications
Oil/Petrochemical
• Refining
• Petrochemical
• Oil Storage
• Pipelines
• Gas Stations
• Stormwater Runoff
Power Generation and Distribution
• Fossil
• Nuclear
• Hydroelectric
• Transformer Switchyards
• Remote Substations
• Underground Transmission
Offshore
• Oil Ports
• Rivers/Lakes
• Desalination Intake Protection
• Jetty Terminals
• Monobuoy Terminals
Transport
• Ships
• Airports
• Railways
• Parking Areas
• Highways
Manufacturing
• Steel/Aluminum
• Pulp and Paper
• Edible Oils
• Pharmaceuticals
• Auto Production
Water
• Wastewater Treatment
• Remediation Sites
• Stormwater Monitoring
• Groundwater Monitoring
ID-223
Operates in dry and wet sumps, open channels, and catch basins.
ID-227WL/PTP
Provides wireless monitoring near offshore oil rigs and other open water areas.
ID-227
Works in a variety of marine and open water applications.
ID-223/2000
ID-223/2500
ID-225
Measures oil thickness for oil/water
separators, oil traps, wet sumps, tanks,
ponds, and monitoring wells.
PS-220
Analog single sensor control
PS-220 Weather Proof
PS-220 Explosion Proof
SLC-220DSP-220
Digital multiple sensor controls
Versatile Signal Processors
ID-223/500
Leakwise Versatile Sensors and Processors
ID-221
Detects floating oil sheens in wet sumps, tanks, ponds, and monitoring wells.
* Trademark of General Electric Company; may be registered in one or more countries.
This information herein may be subject to change without notice and is provided for general guidance only. The dimensions and performance of systems, products and services may vary. Pictures are for example purposes and not to scale. All legal obligations are exclusively as set out in con­tractual documents. Nothing contained herein constitutes a representation, warranty or undertaking.
300 00108 Rev E
MC12-103
©2012, General Electric Company. All rights reserved.
The Americas
GE Analytical Instruments 6060 Spine Road Boulder, CO 80301-3687 USA T +1 800 255 6964 T +1 303 444 2009 F +1 303 527 1797 geai@ge.com
Europe/Middle East/Africa
GE Analytical Instruments Unit 3, Mercury Way Urmston, Manchester UK M41 7LY T +44 (0) 161 864 6800 F +44 (0) 161 864 6829 geai.europe@ge.com
www.geinstruments.com
Asia Pacific
GE Analytical Instruments 7/F, Building 5, No.2 Hua Tuo Rd. ZhangJiang Hi-Tech Park, Pudong Shanghai, China 201203 T +(8621) 38777735 F +(8621) 38777469 geai.asia@ge.com
Loading...