GE P&W E-Series M User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Average Operating Pressure
7–15 bars
Maximum Recovery
75%
Nominal Rejection
90-95%
Operating Temperature
5-35 C
Inlet Pressure
3-6 bars
Design Temperature*
15 C
Frame
Polypropylene frame (E4) Powder coated steel (E4H)
Membrane Elements
AK4040TM
Membrane Housing
Fiberglass Reinforced Plastic
Piping
PN 16
Cartridge Filter
Hytrex*, 5 micron
E-Series M
Medium Reverse Osmosis Machines, 600 to 2700 liters per hour
Standard Features
Automatic inlet shut-off valve Permeate and Concentrate flow meters Pre/post-filter, and primary pressure gauges Inlet low pressure switch Digital conductivity meter with temperature sensor Flow control center including concentrate and recycle
valves
Microprocessor control panel with one potential free
contact for remote alarm, dosing pump or level con­trol for permeate tank
Figure 1: E4 M CE Series
When you mention reverse osmosis (RO), GE Water & Process Technologies is the first name to come to mind. Our E-series RO machines (Figure 1) are de­signed for durable operation, high quality product wa­ter production, easy installation and straightforward control.
General Properties
Typical Applications
Process ingredient water Safe drinking water Boiler feed water
Ion exchange pre-treatment
Optional Features
Clean in Place (CIP) system installed on a polypropyl-
ene frame suitable for retrofit.
Table 1: Operating Parameters
* Varying the operating temperature will affect machine productivity
Table 2: Materials of Construction
Model
E4-CE-600
E4-CE-900
E4-CE-1500
E4H-CE-1800
E4H-CE-2400
E4H-CE-2700
Base System Including CIP
3020807 3021387
3020808 3021388
3020809 3020843
3020840 3020844
3020841 3020845
3020842 3020846
Flow Specifications
Recovery Permeate Rate l/h Concentrate Rate l/h
75%
600
200
75%
900
300
75%
1500
500
75%
1800
600
75%
2400
800
75%
2700
900
Pump and Power
Power Supply
3/400 VAC/50 Hz, Neutral Connection Required
Power Consumption Pump Manufacturer Pump model
1.5 kW KSB
Movitec VF2-13
1.5 kW KSB
Movitec VF2-15
2.2 kW KSB
Movitec VF2-16
2.2 kW KSB
Movitec VF4-13
2.2 kW KSB
Movitec VF4-15
2.2 kW KSB
Movitec VF4-15
Membrane Elements and Filters
Quantity Array Housing Configuration Pre-Filter Model Pre-Filter Quantity
2
1-1
Vertical
GX05-9 ¾
1
3
1-1-1
Vertical
GX05-9 ¾
1
5
1-1-1-1-1
Vertical
GX05-9 ¾
1
6
1-1-1
Horizontal
GX05-20
1
8
2-1-1
Horizontal
GX05-20
1
9
2-1
Horizontal
GX05-20
1
Connections
Inlet Permeate Concentrate
DN 15 DN 15 DN 15
DN 15 DN 15 DN 15
DN 20 DN 15 DN 15
DN 20 DN 15 DN 15
DN 25 DN 20 DN 20
DN 25 DN 20 DN 20
Dimensions & Weights
H*W*D mm (w/o CIP)
1650*720*700
1650*720*700
1650*720*700
1800*2600*750
1800*2600*750
1800*3500*750
H*W*D mm (with CIP)
1650*1120*700
1650*1120*700
1650*1120*700
1800*2600*750
1800*2600*750
1800*3500*750
Average Shipping Weight kg
210 +30 (CIP)
240 +30 (CIP)
315 +30 (CIP)
470 +30 (CIP)
485 +30 (CIP)
710 +30 (CIP)
Table 3: E4H Specifications - 50 Hz
Figure 2: E4 M CE Series, range 600 to 1500 Figure 3: E4H M CE Series, range 1800 to 2700
Page 2 Fact Sheet
Loading...