Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1129EN.doc Jul-13
200-250 psig (13.8-
17.2 bar)
E8 Series 60 Hz
Reverse Osmosis Machine 57,000 to 144,000 gallons per day
- Permeate conductivity sensor
- Permeate tank level monitoring
- SD card for collection of operating data
- ALARMS: Low inlet pressure, high temperature,
high permeate conductivity, motor fault, and
fill-time exceeded
- Remote machine on/off capability
Feed water flush on shut down
Panel-mounted pre-filter, post-filter, primary, and
Figure 1: E8 Series 60 Hz
When you mention reverse osmosis (RO), GE’s Water
& Process Technologies is the first name to come to
mind. Our E-series RO machines (Figure 1) are designed for durable operation, high quality product
water production, easy installation and straightforward
control.
General Properties
Typical Applications
Process ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
final pressure gauges
Deluxe (DLX) Features – in addition to ECN
features
Inlet pH sensor
Chemical dosing pump for antiscalant dosing or pH
adjustment
Clean-In-Place pump plumbed, wired and mount-
ed; remote tank
ALARMS: Same as above plus high/low inlet pH,
high permeate pressure
Table 1: Operating Parameters
Standard Economy Features
Energy saving 400 ft
elements
SS high-pressure piping
1-micron pre-filter and SS housing
Automatic inlet shut-off valve
AccuTrak* RO microprocessor controller
- Permeate and concentrate paddlewheel flow
sensors
2
(37.2 m2) membrane
Table 2: Materials of Construction
SS shell/housing, Noryl* internals
Recovery Range:
Permeate Rate: gpm (m3/h)
Concentrate Rate: gpm (m3/h)
66-75%
40 (9)
21-13 (5-3)
66-75%
60 (14)
30-20 (7-5)
66-75%
75 (17)
39-25 (9-6)
66-75%
100 (23)
52-33 (12-8)
CIP Pump Model: (DLX only)
Membrane Elements and Filters
Membrane Quantity
Array
Pre-Filter Quantity
8
1-1-1
7, RO.Zs 01-40-XK
12
2-1-1
7, RO.Zs 01-40-XK
21
3-2-2
7, RO.Zs 01-40-XK
Inlet: inch (cm)
Permeate: inch (cm)
Concentrate: inch (cm)
2.0 (5.1)
1.5 (3.8)
1.5 (3.8)
2.0 (5.1)
2.0 (5.1)
1.5 (3.8)
2.0 (5.1)
2.0 (5.1)
1.5 (3.8)
3.0 (7.6)
2.0 (5.1)
1.5 (3.8)
Height: inch (cm)
Width: inch (cm)
Depth: inch (cm) ECN
Depth: inch (cm) DLX
76 (193)
153 (388)
42 (107)
91 (231)
76 (193)
153 (388)
42 (107)
91 (231)
76 (193)
153 (388)
42 (107)
91 (231)
76 (193)
153 (388)
42 (107)
103 (262)
Shipping Weight
Estimate: lb (kg)
Shipping Weight
Estimate: lb (kg)
Table 4: E8 Specifications - 60 Hz
Table 3: Pump and Motor