GE P&W E8Series60Hz User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1129EN.doc Jul-13
Operating Pressure
200-250 psig (13.8-
17.2 bar)
Maximum Recovery
75%
Nominal Rejection
95-98%
Operating Temperature
55-85 F (13-30 C)
Minimum Inlet Pressure
30 psig (2 bar)
Design Temperature
77 F (25 C)
E8 Series 60 Hz
Reverse Osmosis Machine 57,000 to 144,000 gallons per day
- Permeate conductivity sensor
- Permeate tank level monitoring
- SD card for collection of operating data
- ALARMS: Low inlet pressure, high temperature,
high permeate conductivity, motor fault, and fill-time exceeded
- Remote machine on/off capability
Feed water flush on shut down Panel-mounted pre-filter, post-filter, primary, and
Figure 1: E8 Series 60 Hz
When you mention reverse osmosis (RO), GE’s Water & Process Technologies is the first name to come to mind. Our E-series RO machines (Figure 1) are de­signed for durable operation, high quality product water production, easy installation and straightforward control.
General Properties
Typical Applications
Process ingredient water Safe drinking water Boiler feed water Ion exchange pre-treatment
final pressure gauges
Deluxe (DLX) Features – in addition to ECN features
Inlet pH sensor Chemical dosing pump for antiscalant dosing or pH
adjustment
Clean-In-Place pump plumbed, wired and mount-
ed; remote tank
ALARMS: Same as above plus high/low inlet pH,
high permeate pressure
Table 1: Operating Parameters
Standard Economy Features
Energy saving 400 ft
elements
SS high-pressure piping 1-micron pre-filter and SS housing Automatic inlet shut-off valve AccuTrak* RO microprocessor controller
- Permeate and concentrate paddlewheel flow
sensors
2
(37.2 m2) membrane
Table 2: Materials of Construction
Frame
Painted Carbon Steel
Membrane Elements
AG8040F
Membrane Housing
FRP
Low Pressure Pipe
Schedule 80 PVC
High Pressure Pipe
Stainless Steel
Motor Starters
NEMA 4
Pump Manufacturer
Tonkaflo
Pump Type
Multi-stage, centrifugal
Materials
SS shell/housing, Noryl* internals
Castings
SS inlet/discharge
Motor
3-phase, TEFC, 460 VAC
Model
E8-57K
E8-86K
E8-108K
E8-144K
ECN DLX
1202846 1202284
1202850 1202286
1202833 1202287
1202835 1202288
Flow Specifications
Recovery Range: Permeate Rate: gpm (m3/h) Concentrate Rate: gpm (m3/h)
66-75%
40 (9)
21-13 (5-3)
66-75%
60 (14)
30-20 (7-5)
66-75%
75 (17)
39-25 (9-6)
66-75% 100 (23)
52-33 (12-8)
Pump and Motor
RO Pump Model
SS8510KA
SS8512KB
SS12508KC
SS24006KE
RO Motor: HP (KW)
15 (11.2)
20 (15)
25 (18.7)
40 (29.8)
CIP Pump Model: (DLX only)
SS5504G
SS5504G
SS8504G
SS8504G
CIP Motor: HP (KW)
5 (3.7)
5 (3.7)
7.5 (5.6)
7.5 (5.6)
Membrane Elements and Filters
Membrane Quantity Array Pre-Filter Quantity
8
1-1-1
7, RO.Zs 01-40-XK
12
2-1-1
7, RO.Zs 01-40-XK
15
3-2
7, RO.Zs 01-40-XK
21
3-2-2
7, RO.Zs 01-40-XK
Connections
Inlet: inch (cm) Permeate: inch (cm) Concentrate: inch (cm)
2.0 (5.1)
1.5 (3.8)
1.5 (3.8)
2.0 (5.1)
2.0 (5.1)
1.5 (3.8)
2.0 (5.1)
2.0 (5.1)
1.5 (3.8)
3.0 (7.6)
2.0 (5.1)
1.5 (3.8)
Dimensions & Weights
Height: inch (cm) Width: inch (cm) Depth: inch (cm) ECN Depth: inch (cm) DLX
76 (193)
153 (388)
42 (107) 91 (231)
76 (193)
153 (388)
42 (107) 91 (231)
76 (193)
153 (388)
42 (107) 91 (231)
76 (193)
153 (388)
42 (107)
103 (262)
Shipping Weight Estimate: lb (kg)
ECN
2600 (1200)
3000 (1360)
3400 (1500)
3800 (1750)
Shipping Weight Estimate: lb (kg)
DLX
2800 (1300)
3300 (1500)
3700 (1700)
4200 (1900)
Table 4: E8 Specifications - 60 Hz
Table 3: Pump and Motor
Page 2 Fact Sheet
Loading...