Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
AM-FSroE8PlusSeries_EN.doc Jun-13
200-250 psig
(13.8-17.2 bar)
E8 Plus Series 50/60 Hz
Reverse Osmosis Machine 216,000 to 288,000 gallons per day
(34-45 m3/hr)
- Permeate tank level monitoring
- SD card for collection of operating data
- ALARMS: Low inlet pressure, high temperature,
high permeate conductivity, motor fault, and
fill-time exceeded
- Remote machine on/off capability
Feed water flush on shut down
Panel-mounted pre-filter, post-filter, primary, and
Figure 1: E8 Series
final pressure gauges
GE’s E-series RO machines (Figure 1) are designed
for durable operation, high quality product water
production, easy installation and straightforward control.
General Properties
Typical Applications
Process ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
Standard Economy Features
Energy saving 400 ft
ments
SS high-pressure piping
1-micron pre-filter and SS housing
Automatic inlet shut-off valve
Burkert mxCONTROL 8620 controller with PC
Ethernet
- Permeate and concentrate paddlewheel flow
sensors
- Permeate conductivity sensor
2
(37.2 m2) membrane ele-
Deluxe (DLX) Features – in addition to ECN
features
Inlet pH sensor
Chemical dosing pump for antiscalant dosing or pH
adjustment
Clean-In-Place pump plumbed, wired and mount-
ed; remote tank
ALARMS: Same as above plus high/low inlet pH,
high permeate pressure, high concentrate pressure
Table 1: Operating Parameters
Table 2: Materials of Construction
SS shell/housing, Noryl* internals
3-phase, TEFC, 460 VAC 60hz
3-phase, TEFC, 380 VAC 50hz
Recovery Range:
Permeate Rate: gpm (m3/h)
Concentrate Rate: gpm (m3/h)
66-75%
150 (34)
77-50 (17-11)
66-75%
200 (45)
103-67 (23-15)
66-75%
150 (34)
77-50 (17-11)
66-75%
200 (45)
103-67 (23-15)
CIP Pump Model: (DLX only)
Membrane Quantity
Array
Pre-Filter Quantity RO.Z 01-40-XK, 3027255
Inlet: inch (cm)
Permeate: inch (cm)
Concentrate: inch (cm)
4.0 (10)
3.0 (7.6)
3.0 (7.6)
4.0 (10)
4.0 (10)
3.0 (7.6)
4.0 (10)
3.0 (7.6)
3.0 (7.6)
4.0 (10)
4.0 (10)
3.0 (7.6)
Height: inch (cm)
Width: inch (cm)
Depth: inch (cm) ECN
Depth: inch (cm) DLX
76 (193)
273 (693)
42 (107)
103 (262)
76 (193)
273 (693)
42 (107)
103 (262)
76 (193)
273 (693)
42 (107)
103 (262)
76 (193)
273 (693)
42 (107)
103 (262)
Shipping Weight
Estimate: lb (kg)
Shipping Weight
Estimate: lb (kg)
Table 4: E8+ Specifications
Table 3: Pump and Motor
Page 2 Fact Sheet