SeaPRO* E-Series
1000 m3/day (184 gpm) Seawater Desalination Machine
General Features
Major components skid-mounted for easy
installation and dependable operation
Variable frequency drive (VFD) for high pressure
pump optimal control, energy efficiency and
constant water production
Simple manual control for the system, and
Hand/Auto control for remote starting and
stopping of the system
Operating Parameters
Recovery .............................................................................. 45%
Design temp. ........................................................ 25ºC (77F)
Operating range .............................. 15-32C (59-90F) 1)
Design Feed TDS ..................................................... 45k ppm
System Nominal rejection ........................................... 99%
Minimum inlet pressure .......................... 2 bar (30 PSIG)
1)
Varying the operating temperature may affect permeate rate
Materials of Construction
High-pressure piping .............. Sch 40 SS Duplex 2205
Low-pressure piping ...... Sch 80 PVC-U DIN PN10/16
Frame ................... Anti-corrosion treated carbon steel
Frame Finish ....... 2-coat epoxy painted & blue finish
Enclosures............................................... IP55 carbon steel
Membranes .................................................................. AD-440
Membrane Housing ..... FRP 8in-1200psi-6M (82 bar)
Cartridge Filters ................. 5-micron nominal, Hytrex*
Cartridge Filter Housing ................................................ PVC
Standard package includes energy recovery
device for operating cost savings
Flow and Conductivity 4-20mA signals available
for remote monitoring/recording
Table 1: Standard Instrumentation
Table 2: Pump and Motor
Permeate rate:
Concentrate Rate:
Feed Rate:
1000 m3/day (184 gpm)
1225 m3/day (225 gpm)
2225 m3/day (409 gpm)
Membrane Elements and Housings
Membranes Quantity:
Memb. Housing Style:
Banking Arrangement:
72
8 housings – 6M long, 4 port and 4 housings - 6M long 2 port
3 x 4, parallel
Cartridge Filter:
Filter Length:
Filter Quantity:
35FTPV-5
50” (127 cm)
35 per change out
Installation and Utility Requirements
Filter Feed:
Filter Outlet:
RO Feed:
Permeate:
Concentrate:
Power:
DIN DN125 PN10/16 flange
DIN DN125 PN10/16 flange
DIN DN150 PN10/16 flange
DIN DN100 PN10/16 flange
DIN DN100 PN10/16 flange
380/420 VAC, 3-phase, 50/60Hz
General Dimensional Information
System Footprint:
Width:
Depth:
Membrane Skid Size:
Height:
Width:
Depth:
7665 mm (302 inches)
2760 mm (109 inches)
2435 mm (96 inches)
7320 mm (288 inches)
1675 mm (66 inches)
Table 3: Energy Recovery Device
Options:
Contact sales for pricing and lead time.
35% Recovery Design
Alternate high-pressure pump manufacturers
Pressure transmitters for remote monitoring/recording
Control circuit transformer for 110 VAC, 1-phase, 60 Hz operation
Table 4: Model SeaPRO-E-72 Specifications