Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FSpwSeaPRO-E-500_EN.doc Jul-13
Feed LP, Feed HP,
Concentrate, Permeate
Pump suction,
Pump discharge,
ERD HP discharge,
ERD LP discharge,
Permeate, Concentrate
Figure 1. SeaPRO-E-36 General Layout (reference only)
SeaPRO* E-Series
500 m3/day (92 gpm) Seawater Desalination Machine
General Features
Major components skid-mounted for easy in-
stallation and dependable operation
Variable frequency drive (VFD) for high pressure
pump optimal control, energy efficiency and
constant water production
Simple manual control for the system, and
Hand/Auto control for remote starting and
stopping of the system
Operating Parameters
Recovery .............................................................................. 40%
Design temp. ........................................................ 25ºC (77F)
Operating range .............................. 15-32C (59-90F) 1)
Design Feed TDS ................................................45,000ppm
System Nominal rejection ........................................... 99%
Minimum inlet pressure .......................... 2 bar (30 PSIG)
1)
Varying the operating temperature may affect permeate rate
Standard package includes energy recovery
device for operating cost savings
Flow and Conductivity 4-20mA signals available
for remote monitoring/recording
Table 1: Standard Instrumentation
Materials of Construction
High-pressure piping .............. Sch 40 SS Duplex 2205
Low-pressure piping ...... Sch 80 PVC-U DIN PN10/16
Frame ................... Anti-corrosion treated carbon steel
Frame Finish ....... 2-coat epoxy painted & blue finish
Enclosures............................................... IP55 carbon steel
Membranes .................................................................. AD-440
Membrane Housing ..... FRP 8in-1200psi-6M (82 bar)
Cartridge Filters ................. 5-micron nominal, Hytrex*
Cartridge Filter Housing ................................................ PVC
Table 2: Pump and Motor
Permeate rate:
Concentrate Rate:
Feed Rate:
500 m3/day (92 gpm)
750 m3/day (138 gpm)
1250 m3/day (230 gpm)
Membrane Elements and Housings
Membranes Quantity:
Memb. Housing Style:
Banking Arrangement:
36
6 housings – 6M long
6 in parallel
Cartridge Filter Housing:
Filter Length:
Filter Quantity:
20FTPV-4 or equivalent
40” (127 cm)
20 per change out
Installation and Utility Requirements
Inlet:
Permeate:
Concentrate:
Power:
DIN DN100 PN10/16 flange
DIN DN65 PN10/16 flange
DIN DN80 PN10/16 flange
380/420 VAC, 3-phase, 50/60Hz
General Dimensional Information
System Footprint:
Width:
Depth:
Membrane Skid Size:
Height:
Width:
Depth:
7010 mm (276 inches)
2287 mm (90 inches)
1950 mm (77 inches)
5968 mm (235 inches)
1849 mm (73 inches)
Table 3: Energy Recovery Device
Options
Contact sales for pricing and lead time.
35% Recovery
Alternate high pressure pump manufacturers
Pressure transmitters for remote monitoring/recording
Control circuit transformer for 110 VAC, 1-phase, 60 Hz operation
Table 4: Model SeaPRO-E-36 Specifications