GE P&W E-36 User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Flow (magnetic)
Permeate, Concentrate
Conductivity
Permeate
Pressure Switch
Feed LP, Feed HP,
Concentrate, Permeate
Pressure Indicators
Pump suction,
Pump discharge,
ERD HP discharge,
ERD LP discharge,
Permeate, Concentrate
Figure 1. SeaPRO-E-36 General Layout (reference only)
SeaPRO* E-Series
500 m3/day (92 gpm) Seawater Desalination Machine
General Features
Major components skid-mounted for easy in-
stallation and dependable operation
Variable frequency drive (VFD) for high pressure
pump optimal control, energy efficiency and constant water production
Simple manual control for the system, and
Hand/Auto control for remote starting and stopping of the system
Operating Parameters
Recovery .............................................................................. 40%
Design temp. ........................................................ 25ºC (77F)
Operating range .............................. 15-32C (59-90F) 1)
Design Feed TDS ................................................45,000ppm
System Nominal rejection ........................................... 99%
Minimum inlet pressure .......................... 2 bar (30 PSIG)
1)
Varying the operating temperature may affect permeate rate
Standard package includes energy recovery
device for operating cost savings
Flow and Conductivity 4-20mA signals available
for remote monitoring/recording
Table 1: Standard Instrumentation
Materials of Construction
High-pressure piping .............. Sch 40 SS Duplex 2205
Low-pressure piping ...... Sch 80 PVC-U DIN PN10/16
Frame ................... Anti-corrosion treated carbon steel
Frame Finish ....... 2-coat epoxy painted & blue finish
Enclosures............................................... IP55 carbon steel
Membranes .................................................................. AD-440
Membrane Housing ..... FRP 8in-1200psi-6M (82 bar)
Cartridge Filters ................. 5-micron nominal, Hytrex*
Cartridge Filter Housing ................................................ PVC
Table 2: Pump and Motor
HP Pump Model
MSS-5035
Manufacturer
FEDCO
Quantity
1
HP Pump Motor
110 kW
Model
HPBe-60
Manufacturer
FEDCO
Quantity
1
Systems Flow Rates
Permeate rate: Concentrate Rate: Feed Rate:
500 m3/day (92 gpm)
750 m3/day (138 gpm)
1250 m3/day (230 gpm)
Membrane Elements and Housings
Membranes Quantity: Memb. Housing Style: Banking Arrangement:
36
6 housings – 6M long
6 in parallel
Cartridge Filtration
Cartridge Filter Housing: Filter Length: Filter Quantity:
20FTPV-4 or equivalent
40” (127 cm)
20 per change out
Installation and Utility Requirements
Inlet: Permeate: Concentrate: Power:
DIN DN100 PN10/16 flange
DIN DN65 PN10/16 flange DIN DN80 PN10/16 flange
380/420 VAC, 3-phase, 50/60Hz
General Dimensional Information
System Footprint: Width: Depth: Membrane Skid Size: Height: Width: Depth:
7010 mm (276 inches)
2287 mm (90 inches)
1950 mm (77 inches)
5968 mm (235 inches)
1849 mm (73 inches)
Table 3: Energy Recovery Device
Options
Contact sales for pricing and lead time.
35% Recovery Alternate high pressure pump manufacturers Pressure transmitters for remote monitoring/recording Control circuit transformer for 110 VAC, 1-phase, 60 Hz operation
Table 4: Model SeaPRO-E-36 Specifications
Page 2 Fact Sheet