Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FSpwSeaPRO-E-2500_EN.doc Jul-13
Feed LP, Feed HP,
Concentrate, Permeate
Prefilter,
Post-filter,
Pump suction,
Pump discharge,
ERD HP discharge,
ERD LP discharge,
Permeate, Concentrate
SeaPRO* E-Series
2500 m3/day (460 gpm) Seawater Desalination Machine
General Features
Major components skid-mounted for easy
installation and dependable operation
Variable frequency drive (VFD) for high pressure
pump optimal control, energy efficiency and
constant water production
Simple manual control for the system, and
Hand/Auto control for remote starting and
stopping of the system
Operating Parameters
Recovery .............................................................................. 45%
Design temp. ........................................................ 25ºC (77F)
Operating range .............................. 15-32C (59-90F) 1)
Design Feed TDS ..................................................... 45k ppm
Nominal rejection ............................................................ 99%
Minimum inlet pressure .......................... 2 bar (30 PSIG)
1)
Varying the operating temperature may affect permeate rate
Standard package includes energy recovery
device for operating cost savings
Flow and Conductivity 4-20mA signals available
for remote monitoring/recording
Table 1: Standard Instrumentation
Materials of Construction
High-pressure piping .............. Sch 40 SS Duplex 2205
Low-pressure piping ........... Sch 80 PVC DIN PN10/16
Frame ................... Anti-corrosion treated carbon steel
Frame Finish ....... 2-coat epoxy painted & blue finish
Enclosures............................................... IP55 carbon steel
Membranes .................................................................. AD-400
Membrane Housing ..... FRP 8in-1200psi-7M (82 bar)
Cartridge Filters ................. 5-micron nominal, Hytrex*
Cartridge Filter Housing ................................................. FRP
Table 2: Pump and Motor
Permeate rate:
Concentrate Rate:
Feed Rate:
2500 m3/day (460 gpm)
3064 m3/day (561 gpm)
5564 m3/day (1021 gpm)
Membrane Elements and Housings
Membranes Quantity:
Memb. Housing Style:
Banking Arrangement:
210
30 housings - 7M long, 4 port ; and 5 housings - 7M long, 2 port
30, parallel
Cartridge Filter:
Filter Length:
Filter Quantity:
120 FTP-4
50” (127 cm)
120 per change out
Installation and Utility Requirements
Filter Feed:
Filter Outlet:
RO Feed:
Permeate:
Concentrate:
Power:
DIN DN200 PN10/16 flange
DIN DN200 PN10/16 flange
DIN DN200 PN10/16 flange
DIN DN150 PN10/16 flange
DIN DN200 PN10/16 flange
400 VAC, 3-phase, 50/60Hz
General Dimensional Information
System Footprint:
Width:
Depth:
Membrane Skid Size:
Height:
Width:
Depth:
10 060 mm (396 inches)
5334 mm (210 inches)
2540 mm (100 inches)
8077 mm (318 inches)
2032 mm (80 inches)
Table 3: Energy Recovery Device
Options:
Contact sales for pricing and lead time.
35% Recovery Design
Alternate high pressure pump manufacturers
Pressure transmitters for remote monitoring/recording
Control circuit transformer for 110 VAC, 1-phase, 60 Hz operation
Table 4: Model SeaPRO-E-210 Specifications
Page 2 Fact Sheet