GE P&W CK Series User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Membrane
C-series , cellulose acetate
Model
Average
permeate flow
gpd (m3/day)
1,2
Average MgSO
4
rejection
1,2
Minimum MgSO4
rejection
1,2
CK8040F
9,000 (34.1)
97.0%
94.0%
Model
Active area
ft2 (m2)
Outer wrap
Part
number
CK8040F
365 (33.9)
Fiberglass
1233927
Model²
Dimensions, inches (cm)
Boxed
A
B1
C3
Weight lbs (kg)
CK8040F
40.0
(101.6)
1.125 (2.86)
7.9
(20.1)
32
(14.5)
Typical Operating Pressure
60-200 psi (414 - 1,379 kPa)
Typical Operating Flux
10-18 GFD (17-30 LMH)
Maximum Operating Pressure
450 psi (3,103 kPa)
Maximum Temperature
Continuous operation: 86°F (30°C) Clean In Place (CIP): 86°F (30°C)
pH Range
Continuous operation: 5.0-6.5, Clean In Place (CIP): 3.0-8.0
Maximum Pressure Drop
Over an element: 12 psi (83 kPa) Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1ppm maximum continuous 30ppm for 30 min. during sanitization
Feedwater
NTU < 1 SDI < 5
CK Series

Water Softening NF Elements (Cellulose Acetate)

The C-Series family, a triacetate/diacetate blend, has a higher flux and better mechanical stability than standard cellulose acetate. C-Series elements offer an increased chlorine resistance compared to thin-film elements.
CK Nanofiltration Elements are used for water sof­tening, color removal, and reduction of THM poten­tial when chlorine is required.
Table 1: Element Specification
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
² Testing conditions: 2,000ppm MgSO4 solution at 225psi (1,551kPa) operating pressure, 77°F, pH 6.5 and 15% recovery.
Table 2: Dimensions and Weight
1
Internal diameter unless specified OD (outside diameter).
² These elements are dried then bagged before shipping.
3
The element diameter (dimension C) is designed for optimum performance in GE Water & Process Technologies pressure vessels. Others pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
Figure 1: Element Dimensions Diagram - Female