Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1265EN.doc Nov-13
C-Series, Cellulose Acetate
Average
permeate flow
gpd (m3/day)
1,2
Average NaCl
rejection
1,2
Minimum NaCl
rejection
1,2
Typical Operating Pressure
140 - 400psi (965-2,758kPa)
Maximum Operating Pressure
Continuous operation: 86°F (30°C)
Clean-In-Place (CIP):: 86°F (30°C
Continuous operation: 5.0-6.5,
Clean-In-Place (CIP): 3.0-8.0
Over an element: 12psi (83kPa)
Per housing: 50psi (345kPa)
1ppm maximum continuous
30ppm for 30 min during sanitization
CE Series
Brackish Water RO Elements (Cellulose Acetate)
The C-Series family, a triacetate/diacetate blend,
has a higher flux and better mechanical stability
than standard cellulose acetate. CA-Series elements
offer an increased chlorine resistance compared to
thin-film elements.
CE Brackish Water Elements are used for brackish
water desalination and process stream concentration.
Figure 2: Element Dimensions Diagram – Male
Table 1: Element Specification
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
² Testing conditions: 2,000ppm NaCl solution at 425psi (2,930kPa) operating
pressure, 77 °F (25°C), pH 6.5 and 15% recovery.
Table 2: Dimensions and Weight
1
These elements are dried then bagged before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Other pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
Figure 1: Element Dimensions Diagram – Female