GE P&W Certified Elements User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Membrane
Thin-Film Membrane (TFM*)
Model
Average
permeate flow
gpd (m3/day)
1,2
Average NaCl
rejection
1,2
Minimum NaCl
rejection
1,2
AG4040FM CERT
2,200 (8.3)
99.5 %
99.0 %
Model
Average
permeate flow
gpd (m3/day)
1,2
Average NaCl
rejection
1,2
Minimum NaCl
rejection
1,2
AK4040FM CERT
2,200 (8.3)
99.0 %
98.0 %
Model
Active area
ft2 (m2)
Outer wrap
Part
number
AG4040FM CERT
85 (7.9)
Fiberglass
1231652
AK4040FM CERT
85 (7.9)
Fiberglass
1231655
Model1
Dimensions, inches (cm)
Boxed
A
B2
C3
Weight lbs (kg)
AG4040FM CERT
40.0
(101.6)
0.75
(1.90) OD
3.9
(9.9) 8 (3.5)
AK4040FM CERT
40.0
(101.6)
0.75
(1.90) OD
3.9
(9.9) 8 (3.5)
Typical Operating Pressure
AG Series: 200 psi (1,379 kPa) AK Series: 100 psi (689 kPa)
Typical Operating Flux
10-20GFD (15-35LMH)
Maximum Operating Pressure
AG Serie: 600 psi (4,137 kPa), AK Serie: 400 psi (3,758 kPa)
Maximum Temperature
All: Continuous operation: 122°F (50°C) AG-AK Series Clean-In-Place (CIP): 122°F (50°C)
pH Range
AG-AK Series: Optimum rejection pH: 7.0-7.5 Continuous operation: 4.0-11.0 Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12psi (83kPa) Per housing: 50psi (345kPa)
Chlorine Tolerance
1,000+ ppm-hours, dechlorination recommended
Feedwater
NTU < 1 SDI < 5
Certified Elements
NSF 61 Certified Drinking Water RO and NF Elements
The National Sanitation Foundation (NSF) provides conformity assessment services in the area of public health for the food preparation and plumbing water industries. NSF is an organization accredited by the American National Standard Institute (ANSI) to certify products against several NSF/ANSI Standards, includ­ing NSF Standard 61. NSF/ANSI Standard 61 is a test­ing protocol that assures customers and regulators that products do not contribute to unsafe levels of contaminants in drinking water.
AG and AK certified elements are selected when in­comparable confidence is requested from drinking water system components.
AG and AK certified elements feature a fiberglass out­er wrap and standard feed spacers.
Figure 1: Element Dimensions Diagram – Male
Table 2: Dimensions and Weight
Table 1: Element Specification
AG Series - RO High Rejection Elements
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
2
Testing conditions: 2,000ppm NaCl solution at 225psi (1,551kPa) operating pres-
sure, 77 °F, pH 7.5 and 15% recovery.
AK Series - RO Low Energy Elements
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
2
Testing conditions: 500ppm NaCl solution at 115 psi (790kPa) operating pressure,
77 °F, pH 7.5 and 15% recovery.
1
These elements are bagged dried before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE Water & Process Technologies pressure vessels. Other pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters