Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1263EN.doc Nov-13
A-series, thin-film membrane (TFM*)
Average
permeate flow
gpd (m3/day)
1,2
Average NaCl
rejection
1,2
Minimum NaCl
rejection
1,2
AK Series
Low Energy Brackish Water RO Elements
The A-Series, family of proprietary thin-film reverse
osmosis membrane elements are characterized by
high flux and high sodium chloride rejection. AK
Low Pressure Brackish Water Elements are selected when high rejection and low operating pressures are desired. These elements allow significant
energy savings since good rejection is achieved at
operating pressures as low as 100 psi (689 kPa).
Table 1: Element Specification
Figure 1: Element Dimensions Diagram - Female
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
2
Testing conditions: 500ppm NaCl solution at 115psi (793kPa) operating pres-
sure, 77°F (25°C), pH7.5 and 15% recovery.
Figure 2: Element Dimensions Diagram - Male
Typical Operating Pressure
10-20 GFD (15-35LMH)
Maximum Operating Pressure
Continuous operation: 122°F (50°C),
Clean In Place (CIP): 122°F (50°C)
Optimum rejection: 7.0-7.5,
Continuous operation: 4.0-11.0,
Clean In Place (CIP): 2.0-11.5
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
1,000+ ppm-hours,
dechlorination recommended
Table 2: Dimensions and Weight
Table 3: Operating and CIP parameters
1
Internal diameter unless specified OD (outside diameter).
² These elements are bagged dried, unless specified WET, before shipping.
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Others pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Page 2 FS1263EN