GE P&W AG HR Series User Manual

AG HR Series
High Rejection Brackish Water RO Elements
Fact Sheet
The A-Series family of proprietary thin-film reverse osmosis membrane is characterized by high flux and high sodium chloride rejection. AG HR brackish water elements are selected when high rejection and operating pressures as low as 200 psi (1,379 kPa) are desired. These elements are recommended for brackish water with salt concentration (TDS) lev­els between 1,000 and 10,000mg/l or when very high salt rejection of monovalent ions is required.
Table 1: Element Specification
Membrane Thin-film membrane (TFM*)
Average
Model
AG-90 2200 (8.3) 99.8% 99.3%
AG-365 9600 (36.3) 99.8% 99.3%
AG-400 10500 (39.7) 99.8% 99.3%
AG-400, 34 10500 (39.7) 99.8% 99.3%
AG-440 11500 (43.5) 99.8% 99.3%
AG-1600 42000 (159.0) 99.8% 99.3%
1
Average salt rejection after 24 hours operation. Individual flow rate
may vary +25%/-15%.
2
Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) oper-
ating pressure, 77°F (25°C), pH7 and 15% recovery.
Model
AG-90 90 (8.4) Fiberglass 3056665
AG-365 365 (33.9) Fiberglass 3056666
AG-400 400 (37.2) Fiberglass 3056667
AG-400, 34 400 (37.2) Fiberglass 3056668
AG-440 440 (40.9) Fiberglass 3056669
AG-1600 1600 (148.6) Fiberglass 3056670
permeate flow
gpd (m3/day)
Active area
ft2 (m2)
Average
1,2
rejection
Outer wrap
NaCl
1,2
Minimum
NaCl
rejection
Part
number
1,2
Table 2: Operating and CIP parameters
Typical Operating Pressure
Typical Operating Flux
Maximum Operating Pressure
Maximum Temperature
pH range
Maximum Pressure Drop
Chlorine Tolerance
Feedwater3
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper. Additionally, finer colloids, particulates and microorganisms that pass through the filter paper and not measured in the SDI test, will poten­tially foul the RO element. For performance consistency and project warranty, please use Winflows projection software and consult your Filters with Membranes representative.
200 psi (1,380 kPa)
10-20GFD (15-35LMH)
600 psi (4,137 kPa)
Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C)
Optimum rejection: 7.0-7.5, Continuous operation 4.0-11.0, Clean-In-Place (CIP): 2.0-11.5
Over an element: 12 psi (83 kPa) Per housing: 50 psi (345 kPa)
1,000+ ppm-hours, dechlorination recommended
NTU < 1 SDI < 5
Figure 1a: Element Dimensions Diagram – Male
Figure 1b: Element Dimensions Diagram – Female
Find a contact near you by visiting www.ge.com/water
* Trademark of General Electric Company; may be registered in one or more countries.
©2011, General Electric Company. All rights reserved.
and clicking on “Contact Us”.
FSpwAGHRSeries_EN Feb-11
Table 3: Dimensions and Weights
Dimensions, inches (cm) Boxed
Model1 Type
A B2 C
AG-90 Male 40.0 (101.6) 0.75 (1.90) 3.9 (9.9) 9 (4)
AG-365 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AG-400 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AG-400, 34 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AG-440 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AG-1600 Female 40.0 (101.6) 3.000 (7.620) 16.0 (40.6) 120 (54)
Weight lbs (kg)
Page 2 FSpwAGHRSeries_EN Feb-11