GE P&W AG HR LF Series User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Model
Active area
ft2 (m2)
Outer wrap
Part
number
AG-90 LF
90 (8.4)
Fiberglass
3056674
AG-400 LF
400 (37.2)
Fiberglass
3042540
AG-400 LF, 34
400 (37.2)
Fiberglass
3056675
AG-440 LF
440 (40.9)
Fiberglass
3056676
Model1
Type
Dimensions, inches (cm)
Boxed
A
B2
C
Weight
lbs (kg)
AG-90 LF
Male
40.0 (101.6)
0.75 (1.90)
3.9 (9.9)
9 (4)
AG-400 LF
Female
40.0 (101.6)
1.125 (2.86)
7.9 (20.1)
35 (16)
AG-400 LF, 34
Female
40.0 (101.6)
1.125 (2.86)
7.9 (20.1)
35 (16)
AG-440 LF
Female
40.0 (101.6)
1.125 (2.86)
7.9 (20.1)
35 (16)
Model
Average
permeate
flow gpd
(m3/day)
1,2
Average NaCl
rejection
1,2
Minimum NaCl
rejection
1,2
AG-90 LF
2200 (8.3)
99.8%
99.3%
AG-400 LF
10500 (39.7)
99.8%
99.3%
AG-400 LF, 34
10500 (39.7)
99.8%
99.3%
AG-440 LF
11500 (43.5)
99.8%
99.3%
Membrane
Thin-film membrane (TFM*)
Typical Operating Pressure
200 psi (1,380 kPa)
Typical Operating Flux
10-20GFD (15-35LMH)
Maximum Operating Pressure
600 psi (4,137 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C)
pH range
Optimum rejection: 7.0-7.5, Continuous operation 4.0-11.0, Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psi (83 kPa) Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1,000+ ppm-hours, dechlorination recommended
Feedwater3
NTU < 1 SDI < 5
AG HR LF Series
High Rejection Low Fouling Brackish Water RO Elements
The A-Series family of proprietary thin-film reverse osmosis membrane are characterized by high flux and high sodium chloride rejection. AG HR LF Brackish Water Elements are selected for the treatment of im­paired water when high rejection is desired. The AG HR LF membrane features a more neutral charge and therefore reduces interactions with potential foulants present in surface water or tertiary effluent.
Table 1: Element Specification
1
Average salt rejection after 24 hours operation. Individual flow rate may
vary +25%/-20%.
2
Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) operating
pressure, 77°F (25°C), pH7 and 15% recovery.
Table 2: Operating and CIP parameters
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper. Additionally, finer colloids, particulates and microorganisms that pass through the filter paper and not measured in the SDI test, will potentially foul the RO element. For performance consistency and project warranty, please use Winflows projection software and consult your Filters with Membranes representative.
Figure 1a: Element Dimensions Diagram – Male
Figure 1b: Element Dimensions Diagram – Female
Table 3: Dimensions and Weights