GE P&W AE HR Series User Manual

Fact Sheet
AE HR Series
High Rejection Low Energy Seawater RO Elements
The AE HR series of proprietary thin film reverse osmosis membrane elements are characterized by an excellent sodium chloride rejection. AE HR series is selected when high quality permeate is demanded from seawater that is relatively high in TDS.
AE HR series new membrane chemistry provides excellent rejection characteristics when operated at seawater operating conditions (pressures exceed­ing 800psi (5,516kPa).
Table 1: Element Specification
Membrane Thin-film membrane (TFM*)
Average
Model
AE-90 2000 (7.6) 99.8% 99.3% 90.0%
AE-400, 34 9000 (34.1) 99.8% 99.3% 90.0%
AE-440 9900 (37.5) 99.8% 99.3% 90.0%
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
2
Testing conditions: 32,000mg/l NaCl & 5mg/l Boron solution at 800psi (5,516kPa)
operating pressure, 77°F (25°C), pH 8.0 and 10% recovery.
Model Active area
AE-90 90 (8.4) Fiberglass 3056660
AE-400, 34 400 (37.2) Fiberglass 3056662
AE-440 440 (40.9) Fiberglass 3056663
permeate
flow gpd
(m3/day)
Figure 1a: Element Dimensions Diagram – Male
1,2
ft2 (m2)
Average
NaCl
rejection
Minimum
NaCl
1,2
rejection
Outer wrap
1,2
Minimum
Boron
Rejection
Part
number
Figure 1b: Element Dimensions Diagram – Female
Table 2: Operating and CIP parameters
Typical Operating Pressure
Typical Operating Flux
Maximum Operating Pressure
Maximum Temperature
pH range
2
Maximum Pressure Drop
Chlorine Tolerance
Feedwater3
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper. Additionally, finer colloids, particulates and microorganisms that pass through the filter paper and not measured in the SDI test, will potential­ly foul the RO element. For performance consistency and project war­ranty, please use Winflows projection software and consult your Filters with Membranes representative.
800psi (5,516kPa)
7-11GFD (12-19LMH)
1,200psi (8,274kPa)
Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C)
Optimum rejection pH: 7.0-7.5, Continuous operation: 4.0-11.0, Clean-In-Place (CIP): 2.0-11.5
Over an element: 12 psi (83 kPa) Per housing: 50 psi (345 kPa)
1,000+ ppm-hours, dechlorination recommended
NTU < 1 SDI < 5
Table 3: Dimensions and Weights
Dimensions, inches (cm) Boxed
Model1 Type
AE-90 Male 40.0 (101.6) 0.75 (1.90) 3.9 (9.9) 9 (4)
AE-400, 34 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AE-440 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
A B2 C
Weight lbs (kg)
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2014, General Electric Company. All rights reserved.
FSsmAEHRSeries_EN Jan-14