GE P&W AD HR Series User Manual

Fact Sheet
AD HR Series
High Rejection Seawater RO Elements
The AD HR Series, family of proprietary thin film reverse osmosis membrane elements, is character­ized by an excellent sodium chloride rejection. AD HR series is selected when high quality perme­ate is demanded from seawater that is relatively high in TDS.
AD HR series new membrane chemistry provides excellent rejection characteristics when operated at seawater operating conditions (pressures exceed­ing 800psi (5,516kPa) and elevated seawater tem­peratures.
Table 1: Element Specification
Membrane Thin-film membrane (TFM*)
Average
Model
AD-90 1500 (5.7) 99.75% 99.3% 93.0%
AD-365 6000 (22.7) 99.75% 99.3% 93.0%
AD-400, 34 6500 (24.6) 99.75% 99.3% 93.0%
AD-440 7100 (26.9) 99.75% 99.3% 93.0%
1
Average salt rejection after 24 hours operation. Individual flow rate
may vary +25%/-15%.
2
Testing conditions: 32,000mg/l NaCl & 5mg/l boron solution at 800psi
(5,516kPa) operating pressure, 77°F (25°C), pH 8.0 and 7% recovery.
permeate
flow gpd
(m3/day)
1,2
rejection
Average
NaCl
1,2
Minimum
NaCl
rejection
1,2
Minimum
Boron
Rejection
Model Active area
ft2 (m2)
AD-90 90 (8.4) Fiberglass 3056651
AD-365 365 (33.9) Fiberglass 3056652
AD-400, 34 400 (37.2) Fiberglass 3056654
AD-440 440 (40.9) Fiberglass 3056655
Outer wrap
Table 2: Operating and CIP parameters
Typical Operating Pressure
Typical Operating Flux
Maximum Operating Pressure
Maximum Temperature
pH range
Maximum Pressure Drop
2
Chlorine Tolerance
Feedwater3
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper. Additionally, finer colloids, particulates and microorganisms that pass through the filter paper and not measured in the SDI test, will potential­ly foul the RO element. For performance consistency and project war­ranty, please use Winflows projection software and consult your Filters with Membranes representative.
800psi (5,516kPa)
7-11GFD (12-19LMH)
1,200psi (8,274kPa)
Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C)
Optimum rejection: 7.0-7.5, Continuous operation 4.0-11.0, Clean-In-Place (CIP): 2.0-11.5
Over an element: 12 psi (83 kPa) Per housing: 50 psi (345 kPa)
1,000+ ppm-hours, dechlorination recommended
NTU < 1 SDI < 5
Part
number
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2014, General Electric Company. All rights reserved.
FSpsADHRSeries_EN.doc Jan-14
Figure 1a: Element Dimensions Diagram – Male
Figure 1b: Element Dimensions Diagram – Female
Table 3: Dimensions and Weights
Dimensions, inches (cm) Boxed
Model1 Type
AD-90 Male 40.0 (101.6) 0.75 (1.90) 3.9 (9.9) 9 (4)
AD-365 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AD-400, 34 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AD-440 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
A B2 C
Weight lbs (kg)
Page 2 Fact Sheet