AD HR Series
High Rejection Seawater RO Elements
The AD HR Series, family of proprietary thin film
reverse osmosis membrane elements, is characterized by an excellent sodium chloride rejection.
AD HR series is selected when high quality permeate is demanded from seawater that is relatively
high in TDS.
AD HR series new membrane chemistry provides
excellent rejection characteristics when operated at
seawater operating conditions (pressures exceeding 800psi (5,516kPa) and elevated seawater temperatures.
Table 1: Element Specification
Membrane Thin-film membrane (TFM*)
Average
Model
AD-90 1500 (5.7) 99.75% 99.3% 93.0%
AD-365 6000 (22.7) 99.75% 99.3% 93.0%
AD-400, 34 6500 (24.6) 99.75% 99.3% 93.0%
AD-440 7100 (26.9) 99.75% 99.3% 93.0%
1
Average salt rejection after 24 hours operation. Individual flow rate
may vary +25%/-15%.
2
Testing conditions: 32,000mg/l NaCl & 5mg/l boron solution at 800psi
(5,516kPa) operating pressure, 77°F (25°C), pH 8.0 and 7% recovery.
permeate
flow gpd
(m3/day)
1,2
rejection
Average
NaCl
1,2
Minimum
NaCl
rejection
1,2
Minimum
Boron
Rejection
Model Active area
ft2 (m2)
AD-90 90 (8.4) Fiberglass 3056651
AD-365 365 (33.9) Fiberglass 3056652
AD-400, 34 400 (37.2) Fiberglass 3056654
AD-440 440 (40.9) Fiberglass 3056655
Outer wrap
Table 2: Operating and CIP parameters
Typical Operating Pressure
Typical Operating Flux
Maximum Operating Pressure
Maximum Temperature
pH range
Maximum Pressure Drop
2
Chlorine Tolerance
Feedwater3
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper.
Additionally, finer colloids, particulates and microorganisms that pass
through the filter paper and not measured in the SDI test, will potentially foul the RO element. For performance consistency and project warranty, please use Winflows projection software and consult your Filters
with Membranes representative.
800psi (5,516kPa)
7-11GFD (12-19LMH)
1,200psi (8,274kPa)
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
Optimum rejection: 7.0-7.5,
Continuous operation 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
1,000+ ppm-hours,
dechlorination recommended
NTU < 1
SDI < 5
Part
number
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2014, General Electric Company. All rights reserved.
FSpsADHRSeries_EN.doc Jan-14
Figure 1a: Element Dimensions Diagram – Male
Figure 1b: Element Dimensions Diagram – Female
Table 3: Dimensions and Weights
Dimensions, inches (cm) Boxed
Model1 Type
AD-90 Male 40.0 (101.6) 0.75 (1.90) 3.9 (9.9) 9 (4)
AD-365 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AD-400, 34 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AD-440 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
A B2 C
Weight
lbs (kg)
Page 2 Fact Sheet