GE Profile PSB9240EFES Specifications

2x4’s or equivalent solid floor
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4" minimum from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Must Support 150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout. B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Must Support 150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout. B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
1" Min. above toekick or adjust to oven installation height
2" MIN between cutouts
2-1/2" MIN between cutouts recommended—2" MIN required
9-1/4" cutout height 28-1/2" cutout width
Junction box location
A
B
A
B
Construct Solid Bottom MIN 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Must Support 150 lbs. for Advantium) (Must Support 200 lbs. for Wall Oven)
4-3/16
Conduit
(46" long)
Cabinet width
(240-volt models only)
21-1/2"
To back
of Control
19-1/8"
C
L
2x4’s or equivalent solid floor
21-5/8"
over centerline
of cabinet
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Must Support 150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout. B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
29-3/4"
PSB9240EF
GE Profile™ Series 30 in. Single Wall Oven with Advantium
ADVANTIUM WALL OVEN/GE PROFILE™ SERIES COOKING TOWER DIMENSIONS AND CABINET INSTALLATION INFORMATION (IN INCHES)
NOTE: Cabinets
installed adjacent to wall ovens must have an adhesion spec of at least a 194°F temperature rating.
NOTE: 2" minimum between cutouts when installed
drawer or single
above warming
wall oven.
INSTA L L ATION INFORMATION:
Before installing, consult installation instructions packed with product for current dimensional data.
NOTE: Advantium 240 volt models cannot be installed under 36 inches height.
NOTE: Use of the accessory drawer will replace the bottom trim piece for
applicable installations. Please see installation instructions for full details.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
®
C
L
2x4’s or equivalent solid floor
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
Listed by Underwriters Laboratories
(Must support 130 lbs.)
Specification Created 2/16
PSB9240EF
Installation over a GE/Monogram Warming Drawer:
23-1/2”
Warming Drawer:
Construct Solid Bottom Min. 3/8” Plywood Supported by 2x4 or 2x2 Runners all Four Sides
30”
23-1/2”
21”
2” Min.
Per Oven Requirement
Per warming drawer requirement
2” Min. (3” recommended)
25-1/4”
Min.
5” min.
from floor
1” min.
above
toekick
GE Profile™ Series 30 in. Single Wall Oven with Advantium
PREPARATION WITH AN ACCESSORY DRAWER
®
PREPARE THE OPENING: The Advantium 240V can be installed in combination with other GE/Monogram appliances. Always follow each product's Installation Instructions to compete the installation.
SING LE OVE N I NSTALL AT I ON: Order a 30" wide single oven cabinet or cut the opening in a wall to the dimensions shown.
30”
* For existing cutouts, a maximum width of 28-1/2" is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the
21”
oven.
- Always maintain 36-3/4" minimum height from the floor to the cutout in any single or combined
5” min.
from floor
1” min.
above
toekick
installation.
- Allow 3/4" to 2-1/8" case trim overlap on the sides and 7/8" overlap on the bottom of the opening for all models. The amount of overlap on the sides depends on the actual cutout width. Allow 1-1/4" case trim overlap on the top for models PSB9240 and for models ZSC2200, ZSC2201 and ZSC2202.
- Oven overlaps will conceal cut edges on all sides of the opening.
25-1/4”
Min.
Construct Base Min. 3/8” Plywood Supported by 2x4 or 2x2 Runners all Four Sides
PREPARE THE OPENING (CONT.)
When installed over a single oven or a warming drawer, allow at least 2" between the two openings. This separation will provide clearance for bottom overlap of the Advantium 240V and the other appliance overlaps.
Construct a solid oven floor of 3/8" min. thick plywood supported by 2 x 4 or 2 x 2 runners on all sides.
- the support must be level and rigidly mounted, flush with the bottom edge of the cutout.
5” min.
from floor
1” min.
above
toekick
30”
21”
23-1/2”
25-1/4”
Min.
Construct Solid Bottom Min. 3/8” Plywood Supported by 2x4 or 2x2 Runners all Four Sides
2” Min. (3” recommended)
Per warming drawer requirement
* For existing cutouts, a maximum width of 28-1/2" is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the oven.
NOTE: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details.
INSTALLATION OVER A GE/ MONOGRAM OVEN AND WAR M I NG DRAWER:
* For existing cutouts, a maximum width of 28-1/2" is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the oven.
NOTE: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details.
CAUTION: For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of this approximate 80-pound oven and 30-pound drawer, plus additional oven loads of up to 50 pounds or a total weight of 160 pounds.
Specification Created 2/16
Loading...
+ 1 hidden pages