2x4’s or
equivalent
solid floor
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box
location
(240-volt
models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout.
B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box
location
(240-volt
models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout.
B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
1" Min. above toekick or adjust
to oven installation height
2" MIN between cutouts
2-1/2" MIN between cutouts
recommended—2" MIN required
9-1/4" cutout height
28-1/2" cutout width
Junction box location
A
B
A
B
Construct Solid Bottom
MIN 3/8" Plywood Supported by
2 x 4 or 1 x 2 Runners, all Four Sides.
(Must Support 150 lbs. for Advantium)
(Must Support 200 lbs. for Wall Oven)
4-3/16
Conduit
(46" long)
Cabinet width
(240-volt models only)
21-1/2"
To back
of Control
19-1/8"
C
L
2x4’s or
equivalent
solid floor
21-5/8"
over centerline
of cabinet
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box
location
(240-volt
models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout.
B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
29-3/4"
PSB9240EF
GE Profile™ Series 30 in. Single Wall Oven with Advantium
ADVANTIUM WALL OVEN/GE PROFILE™ SERIES COOKING
TOWER DIMENSIONS AND CABINET INSTALLATION
INFORMATION (IN INCHES)
NOTE: Cabinets
installed adjacent
to wall ovens must
have an adhesion
spec of at least a
194°F temperature
rating.
NOTE: 2" minimum
between cutouts
when installed
drawer or single
above warming
wall oven.
INSTA L L ATION
INFORMATION:
Before installing,
consult installation
instructions packed
with product for current
dimensional data.
NOTE: Advantium 240 volt models cannot be installed under 36 inches height.
NOTE: Use of the accessory drawer will replace the bottom trim piece for
applicable installations. Please see installation instructions for full details.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
®
Technology
C
L
2x4’s or
equivalent
solid floor
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
Listed by
Underwriters
Laboratories
(Must support 130 lbs.)
Specification Created 2/16
PSB9240EF
Installation over a GE/Monogram
Warming Drawer:
Warming Drawer:
Construct Solid
Bottom Min.
3/8” Plywood
Supported by
2x4 or 2x2
Runners all
Four Sides
30”
23-1/2”
21”
2” Min.
Per Oven
Requirement
Per warming drawer requirement
2” Min.
(3” recommended)
25-1/4”
Min.
5” min.
from floor
1” min.
above
toekick
GE Profile™ Series 30 in. Single Wall Oven with Advantium
PREPARATION WITH AN ACCESSORY DRAWER
®
Technology
PREPARE THE OPENING: The Advantium 240V can
be installed in combination with other GE/Monogram
appliances. Always follow each product's Installation
Instructions to compete the installation.
SING LE OVE N I NSTALL AT I ON: Order a 30" wide
single oven cabinet or cut the opening in a wall to the
dimensions shown.
30”
* For existing cutouts, a
maximum width of 28-1/2"
is acceptable. If the opening
is slightly wider, secure a
furring strip on each side of
the cutout for securing the
21”
oven.
- Always maintain 36-3/4"
minimum height from
the floor to the cutout in
any single or combined
5” min.
from floor
1” min.
above
toekick
installation.
- Allow 3/4" to 2-1/8" case
trim overlap on the sides and 7/8" overlap on the
bottom of the opening for all models. The amount
of overlap on the sides depends on the actual cutout
width. Allow 1-1/4" case trim overlap on the top for
models PSB9240 and for models ZSC2200, ZSC2201
and ZSC2202.
- Oven overlaps will conceal cut edges on all sides of
the opening.
25-1/4”
Min.
Construct
Base
Min. 3/8”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
PREPARE THE OPENING (CONT.)
When installed over a single oven
or a warming drawer, allow at least
2" between the two openings. This
separation will provide clearance for
bottom overlap of the Advantium 240V
and the other appliance overlaps.
Construct a solid oven floor of 3/8" min.
thick plywood supported by 2 x 4 or 2 x
2 runners on all sides.
- the support must be level and rigidly
mounted, flush with the bottom edge of
the cutout.
5” min.
from floor
1” min.
above
toekick
30”
21”
23-1/2”
25-1/4”
Min.
Construct
Solid Bottom
Min. 3/8”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
2” Min.
(3” recommended)
Per warming
drawer
requirement
* For existing cutouts, a maximum width
of 28-1/2" is acceptable. If the opening is
slightly wider, secure a furring strip on each
side of the cutout for securing the oven.
NOTE: Additional clearances between
the cutouts may be required. Check to be
sure the oven supports above the Warming
Drawer location do not obstruct the
required interior depth and height. See
Warming Drawer installation instructions
for details.
INSTALLATION OVER A GE/
MONOGRAM OVEN AND
WAR M I NG DRAWER:
* For existing cutouts, a maximum width
of 28-1/2" is acceptable. If the opening
is slightly wider, secure a furring strip on
each side of the cutout for securing the
oven.
NOTE: Additional clearances between the
cutouts may be required. Check to be sure
the oven supports above the Warming
Drawer location do not obstruct the
required interior depth and height. See
Warming Drawer installation instructions
for details.
CAUTION: For personal safety, the
mounting surface must be capable of
supporting the cabinet load, in addition
to the added weight of this approximate
80-pound oven and 30-pound drawer, plus
additional oven loads of up to 50 pounds
or a total weight of 160 pounds.
Specification Created 2/16