GE Profile PSB42YSKSS Specifications

PSB42YSK
GE Profile™ Series 42" Built-In Side-By-Side Refrigerator with Dispenser
DIMENSIONS AND INSTALLATION INFORMATION
PRODUCT CLEARANCES
These refrigerators are equipped with a 2-position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.
130° DOOR SWING 90° DOOR SWING
A
MODELS A B C D
42" 12-3/16" 16" 24" 4"
B
23-7/8"
BEHIND FRAME
C
D
D
Allow minimum clearances for Freezer door (Dimension A) and Fresh Food door (Dimension B) for a full 130° door swing and to allow for drawer removal.
Four inch (4") minimum clearance is required when door swing is adjusted to 90°. If the 90° door stop position is used, drawer access is maintained, but drawer removal is restricted.
STAINLESS STEEL WRAPPED REFRIGERATORS
Stainless Steel wrapped refrigerators have wrapped doors and grille panels, and beveled edges. These models are shipped ready for installation.
25-3/8"
CASE DEPTH
41"
CASE WIDTH
*81-3/4" AT REAR
42" FRAME-TO-FRAME
DEPTH INCLUDING HANDLES 27"
*84" FROM FLOOR TO TOP FRAME
* Shipping height
* The front height may be adjusted from
83-1/2" to 84-1/2" by adjusting front and rear leveling legs a maximum of 1".
For answers to your Monogram, GE Profile™ Series or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers’ standards.
Listed by Underwriters Laboratories
Speci fication Revise d 10/15
PSB42YSK
GE Profile™ Series 42" Built-In Side-By-Side Refrigerator with Dispenser
DIMENSIONS AND INSTALLATION INFORMATION
GROUNDING THE REFRIGERATOR
IMPORTANT—PLEASE READ CAREFULLY
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The power supply cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong (grounding) wall receptacle to minimize the possibility of electric shock hazard from this appliance.
SIDE PANELS
Side panels (not supplied) must be used whenever the sides of the refrigerator will be exposed. The 1/4" side panels will slip into the side case trim. Order side panels from your cabinet manufacturer.
* Depending on installation height.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD
FLOORING
For proper installation, this refrigerator must be placed on a level surface of hard material that is at the same height as the rest of the flooring. This surface should be strong enough to support a fully loaded refrigerator, or approximately 1500 lbs.
NOTE: Protect the finish of the flooring. Cut a large section of the cardboard carton and place under the refrigerator where you are working.
(GROUND) PRONG FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO CONNECT THE REFRIGERATOR
WATER AND ELECTRICAL LOCATIONS
The opening must be prepared with the electrical and water supply located as shown.
TO A 2-PRONG OUTLET.
THE CUTOUT DEPTH MUST BE 24"
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
The refrigerator will project forward, slightly beyond adjacent cabinets, depending on your installation.
For answers to your Monogram, GE Profile™ Series or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
*84"
24"
*3" TO 4"
1-1/2"
THE IN STALL AT I ON SPAC E
3"
*Finished Width
7"
84 1/2" max
83 1/2" min
Finished Opening
Electrical
Area
24"
Water
5" 5"
Supply
3 1/2"
7"
74"
From Floor
to Bottom
of Electrical
3 1/2"
* The finished
cutout width must be: 41-1/2" for 42" models
ADDITIONAL SPECIFICATIONS
A 120 volt, 60Hz, 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
Water line can enter the opening through the floor or rear wall. The water line installed should be 1/4" O.D. copper tubing or GE SmartConnect™ tubing between the cold water line and water connection location. The line should be long enough to extend to the front of the refrigerator. Installation of an easily accessible shutoff valve in the water line is required.
Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers’ standards.
Listed by Underwriters Laboratories
Speci fication Revise d 10/15