PSB42YSK
GE Profile™ Series 42" Built-In Side-By-Side Refrigerator with Dispenser
DIMENSIONS AND INSTALLATION INFORMATION
PRODUCT CLEARANCES
These refrigerators are equipped with a 2-position
door stop. The factory set 130° door swing can be
adjusted to 90° if clearance to adjacent cabinets or
walls is restricted.
130° DOOR SWING 90° DOOR SWING
A
MODELS A B C D
42" 12-3/16" 16" 24" 4"
B
23-7/8"
BEHIND
FRAME
C
D
D
Allow minimum clearances for Freezer door
(Dimension A) and Fresh Food door (Dimension B)
for a full 130° door swing and to allow for drawer
removal.
Four inch (4") minimum clearance is required when
door swing is adjusted to 90°. If the 90° door stop
position is used, drawer access is maintained, but
drawer removal is restricted.
STAINLESS STEEL WRAPPED REFRIGERATORS
Stainless Steel wrapped refrigerators have wrapped
doors and grille panels, and beveled edges. These
models are shipped ready for installation.
25-3/8"
CASE DEPTH
41"
CASE WIDTH
*81-3/4"
AT REAR
42" FRAME-TO-FRAME
DEPTH INCLUDING
HANDLES 27"
*84" FROM
FLOOR TO
TOP FRAME
* Shipping height
* The front height may be adjusted from
83-1/2" to 84-1/2" by adjusting front
and rear leveling legs a maximum of 1".
For answers to your Monogram, GE Profile™ Series
or GE® Series appliance questions, visit our website
at geappliances.com or call GE Answer Center®
service, 800.626.2000.
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
Listed by
Underwriters
Laboratories
Speci fication Revise d 10/15

PSB42YSK
GE Profile™ Series 42" Built-In Side-By-Side Refrigerator with Dispenser
DIMENSIONS AND INSTALLATION INFORMATION
GROUNDING THE REFRIGERATOR
IMPORTANT—PLEASE READ CAREFULLY
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
The power supply cord of this appliance is
equipped with a three-prong (grounding) plug
which mates with a standard three-prong
(grounding) wall receptacle to minimize the
possibility of electric shock hazard from this
appliance.
SIDE PANELS
Side panels (not supplied)
must be used whenever
the sides of the refrigerator
will be exposed. The 1/4"
side panels will slip into
the side case trim. Order
side panels from your
cabinet manufacturer.
* Depending on installation height.
Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
Where a standard 2-prong wall outlet is
encountered, it is your personal responsibility
and obligation to have it replaced with a properly
grounded 3-prong wall outlet.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT
OR REMOVE THE THIRD
FLOORING
For proper installation, this refrigerator must be
placed on a level surface of hard material that
is at the same height as the rest of the flooring.
This surface should be strong enough to support
a fully loaded refrigerator, or approximately 1500 lbs.
NOTE: Protect the finish of the flooring. Cut a
large section of the cardboard carton and place
under the refrigerator where you are working.
(GROUND) PRONG FROM
THE POWER CORD.
DO NOT USE AN ADAPTER PLUG
TO CONNECT THE REFRIGERATOR
WATER AND ELECTRICAL LOCATIONS
The opening must be prepared with the
electrical and water supply located as shown.
TO A 2-PRONG OUTLET.
THE CUTOUT DEPTH MUST BE 24"
DO NOT USE AN EXTENSION CORD
WITH THIS APPLIANCE.
The refrigerator will project forward, slightly
beyond adjacent cabinets, depending on your
installation.
For answers to your Monogram, GE Profile™ Series
or GE® Series appliance questions, visit our website
at geappliances.com or call GE Answer Center®
service, 800.626.2000.
*84"
24"
*3" TO 4"
1-1/2"
THE IN STALL AT I ON SPAC E
3"
*Finished Width
7"
84 1/2" max
83 1/2" min
Finished
Opening
Electrical
Area
24"
Water
5" 5"
Supply
3 1/2"
7"
74"
From Floor
to Bottom
of Electrical
3 1/2"
* The finished
cutout width must
be: 41-1/2" for
42" models
ADDITIONAL SPECIFICATIONS
A 120 volt, 60Hz, 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
Water line can enter the opening through the floor or
rear wall. The water line installed should be 1/4" O.D.
copper tubing or GE SmartConnect™ tubing between
the cold water line and water connection location. The
line should be long enough to extend to the front of the
refrigerator. Installation of an easily accessible shutoff
valve in the water line is required.
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
Listed by
Underwriters
Laboratories
Speci fication Revise d 10/15