GE Profile™ 7.3 cu. ft. Capacity Smart Electric Dryer with Fabric Refresh
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRIC DRYER RATING:
240V5600W24A60Hz
208V4400W22A60Hz
EXHAUST OPTION: 4-way rear, right, left and bottom
CIRCUIT REQUIREMENTS: An individual, properly-grounded branch circuit,
protected by a 30-amp circuit breaker or a time-delay fuse, is required.
NOTE: Dryer wall outlet must be located within 36" of service cord entry and
acessible when dryer is mounted in position.
INS TA LLATI O N IN F O RMATI O N: For complete information, see installation
instructions packed with your dryer.
Special Installation Requirements
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated
on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 1" front, top and rear
- Closet doors must be louvered or otherwise ventilated and must contain a minimum
of 60 sq. in. of open area equally distributed. If this closet contains both a washer
and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with
the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 1" rear
DRYER EXHAUSTING INFORMATION : Use metal duct only, vertical and horizontal ducting.
SIDE VIEW
POWER CORD LOCATIONS
REAR VIEW
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center® Service, 800.626.2000.
Listed by
Underwriters
Laboratories
BACK VIEW
Specif ication Revised 1/22
Page 2
PTD90EBPTDG/RS
GE Dryer Vent
2-1/2
GE Profile™ 7.3 cu. ft. Capacity Smart Electric Dryer with Fabric Refresh
FOR COMPLETE INFORMATION, SEE INSTALLATION INSTRUCTIONS PACKED
WITH YOUR DRYER.
DUCTING MATERIALS:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust
duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting
can be used (Kit WX08X10077). In special installations, it may be necessary to connect the
dryer to the house vent using a f lexible metal (foil-type) duct. A UL-listed flexible metal (foiltype) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid)
ducting cannot be used AND where a 4" diameter can be maintained throughout the entire
length of the transition duct. Please see installation instruction packed with your dryer for
complete instructions when using flexible metal (foil type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or
bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is
shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct
length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
CAUTION: For personal safety do not terminate exhaust into a chimney, under any enclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard
or moisture could cause damage. Never terminate the exhaust into a common duct or plenum
with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed down.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES,
PLEASE CALL 1-800-GE-CARES.
DRYER EXHAUSTING INFORMATION—
USE METAL DUCT ONLY VERTICAL AND
HORIZONTAL DUCTING
BEST PERFORMANCE
Maximum length
of 4" dia rigid
A
4
Domestic dryer models
Long Vent 6.1-7.4 cu. ft.capacity electric & gas(GTD33, GTD42, GTD45,GTD65, GTX22, GTX33, GTX42and GTX65)
For every extra 90° elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the chart.
When calculating the total vent system length, you must add all
the straight portions and elbows of the system (including the
transition duct.
B
Number
of 90°
metal duct
Exhaust hood type
A
turns
0120 ft.90 ft.
1100 f t.75 ft.
285 ft.65 ft.
370 ft.55 ft.
460 f t.45 ft.
555 ft.35 ft.
4"
opening
opening
B
2-1/2"
Specif ication Revised 1/22
Page 3
PTD90EBPTDG/RS
GE Profile™ 7.3 cu. ft. Capacity Smart Electric Dryer with Fabric Refresh
FEATURES AND BENEFITS
Fabric Refresh – Refresh lightly worn items without needing to wash them, or diffuse a chosen
scent during tumbling to freshen your garments with this innovative dryer technology.
Steam – Refresh small loads and dewrinkle larger loads with the power of steam.
Tangle Control – Intelligent technology adapts the drum movements to minimize tangled loads
and provide even drying.
Washer Link – Wirelessly connects the washer to the dryer, enabling the dryer to automatically
set the optimal settings based on the load that was just washed.
Reduce Static – Prevent static cling with a gentle mist near the end of the cycle.
Smart Features powered by SmartHQ™ – Ensure your dryer always has the latest features,
including extra cycles for active wear and casuals. Plus, easily control and monitor your laundry
from anywhere, receive remote status notifications and more.
Sensor Dry – Innovative dual thermistor technology continually monitors temperature and
moisture to prevent over-drying and protect your laundry.
Sanitize Cycle – Reduces 99.8% of bacteria found in laundry.
Check Vent Notification – Receive a notification when the dryer vent needs to be cleaned, ensuring
safe operation and optimal drying performance.
120 ft. Venting – Innovative 120 ft. venting enables optimal airflow, enhanced drying ability
and flexible installation.
My Cycle – Streamline your laundry process by saving your favorite dryer settings for future use.
Quick Dry – Quickly dries a variety of loads for families on the go.
ENERGY STA R® qualified – Meets or exceeds federal guidelines for energy efficiency for
year-round energy and money savings.
Model PTD90EBPTDG – White with silver backsplash
Model PTD90EBPTRS – Diamond Gray
Listed by
Underwriters
Laboratories
Specif ication Revised 1/22
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.