GeoVision DCV1-A-EN User Manual

2005/01
GV-Data Capture
1
GV-Data CaptureGV-Data Capture
Introduction
Packing List
GV-Data Capture
POS System Connection
Cash Register Connection
GV-Net Extension
Troubleshooting
Specifications
1
1
1
2
3
3
6
8
8
9
10
10
10
11
13
14
15
Table of Contents
A POS system may be integrated to a GV-system through the GV-Data
Capture box. Through the integration, you can investigate a transaction
with transaction data overlaying on a video footage, by either live viewing
or playing back.
Introduction
Version: 6.0.2.0 or above
System Requirements
GV-Data Capture box
DB9 RS-232 cable (1.8 meters)
DB9 RS-232 cable (3 meters)
DB25 parallel cable
Power Adapter DC 5V
DB25 Female to DB9 Male (Crossover) No.1
DB25 Male to DB9 Female (Crossover) No.2
DB9 Male to DB9 Male (Gender Changer) No.4
DB9 Female to DB9 Female (Gender Changer) No.5
DB25 Male Printer Terminator
Packing List
Displaying errors in transaction data
Transaction events don't stop properly
Connecting more than 2 POS systems/cash registers
The displayed transaction item can't match that entered
at the POS system/cash register
Serial POS System
Parallel POS System
Serial Cash Register
Parallel Cash Register
3
2
GV-Data CaptureGV-Data Capture
POS systems could come in different forms. In this manual, POS systems
are referred to those with receipt printers externally connected. Before
configuring, it is important to identify the interface type of your POS system.
It must be either serial or parallel.
POS System Connection
Our default settings are set to support serial POS systems, since most of
the POS systems available in market are serial. Follow these steps to
make the connection:
1. Connect the GV-Data Capture box as illustrated below:
POS System Using a DB9-D25 Cable
The RS-232 cables supplied with the GV-Data Capture box.
The RS-232 cable supplied with the POS system.
Serial POS System
The GV-Data Capture box is designed to connect a GV-system to a POS
system through PC COM ports.
GV-Data Capture
123456781234
1 2 3 4
5679 8
Note: The default baud rate is set to 9,600 bps and the default DIP is set for the serial port.
1 25 pins parallel connector Connects to a parallel printer
2 9 pins D-Sub male connector Connects to a serial printer
3 2 pins RS-485 connector Connects to the GV-NET box or GV-NET card
4 9 pins D-Sub RS-232 connector Connects to a GV-system COM port
5 25 pins parallel connector Connects to a parallel POS system
6
9 pins D-Sub female connector
Connects to a serial POS system
7 The 4-position baud-rate switch
settings are to configure the parallel connection only. If you are using a serial POS system, the settings are not necessary.
8 The 8-position DIP switch settings
are to configure the serial or parallel connection.
9 5V DC-IN
1234
1,200 bps
1234
1234
1234
1234
1234
1234
1234
2,400 bps 4,800 bps 9,600 bps
19,200 bps 38,400 bps 57,600 bps 115,200 bps
12345678 12345678
Parall el Port Serial Port
DB25
Male
DB9 Female
GV-Sys tem
POS System
DB9
Female
DB9 Female
DB9 Male
DB9 Male
Printer
RS-232
2
21
3
RS-232
3
RS-232
1
GeoVision GV-DATA CAPTURE