Georgia-Pacific DensArmor Plus Interior Panels User Manual

Priming Tips
Primer application guidelines for DensArmor Plus®
Interior Panels in accordance with standards developed
by the Rohm and Haas Paint Quality Institute
SM
DENSARMORPLUS
A mock-up or test wall should be used to ensure the proposed
decorative finish will produce an acceptable result. Proper
installation, finishing and priming are critical. Skipping a step,
such as the application of a primer, or taking shortcuts, such as
not using proper sanding techniques, will negatively impact the
quality of the final decorative finish. Because many factors that
are unrelated to the manufacture of the panels can affect the
acceptability of the final finish result, Georgia-Pacific Gypsum
®
results to be achieved with DensArmor Plus
guidelines for priming DensArmor Plus Interior Panels have
been developed by the Rohm & Haas Paint Quality Institute.
For best results, please use the following steps for priming
DensArmor Plus Interior Panels.
1. A high solids primer with at least 40% volume solids
should be used. The primer can best be applied by roller at a
higher film thickness in one coat. (vs. brush or spray applied)
2. For adequate coverage, the primer should be applied to
a dry film thickness of 1.7 to 1.8 mils dry to ensure uniform
coverage and appearance. The number of coats to achieve
the dry film thickness will depend on the primer used.
For instance, a primer with lower than 37% volume solids
may need two coats for adequate coverage.
% Volume Solids Spread Rate, of Primer square feet/ gallon
37 330-350
40 355-380
43 380-400
47 420-450
panels. The following
3
3. For best results, apply the high solids primer with a
(10 mm) nap roller at a natural application rate.
1
4. It is possible to use a
thicker coat. However, the roller pattern is more
pronounced and some may find it objectionable.
5. To maximize the mold-resistant benefit of the DensArmor
Plus Interior Panels, a 100% acrylic primer with mildecide
should be used.
6. High-quality flat or satin paint should be applied over
the primer. Semi-Gloss or Gloss paints are not
recommended.
Primers that may provide suitable finishing include
the following:*
a. ICI Paints Glidden
Primer/Sealer GL3210–1200
b. ICI Paints Prep and Prime
Exterior Water Based Primer Sealer 3210–1200
c. Pratt and Lambert Paints. SUPRIME® Interior Latex
Enamel Undercoater Z1013/F1013
®
d. Do It Best
e. Do It Best
f. Sherwin Williams
g. Mythic™ Multi-Purpose Interior/Exterior Latex Primer
* Please note that Georgia-Pacific Gypsum makes no warranty regarding the primers and surfacers identified above or the finishing results obtained by such products. As indicated, a mock up or test wall should be used to ensure the proposed decorative finish will produce an acceptable result. For further information regarding finishing of DensArmor Plus interior panels, please see Georgia-Pacific Gypsum’s
Technical Guide for such panels available at www.gpgypsum.com.
Interior Latex Wood & Wall Primer
®
Latex Stainblocker Primer
2( (13 mm) nap roller and apply a
®
Gripper® Interior/Exterior Stain Killer
®
Gripper Multi-Purpose Interior/
®
Builders Solution
®
8(
continued
®
DENSARMORPLUS
®
High Build surfacers that may provide suitable finishing include the following:*
a. ICI Paints Prep and Prime Fill & Seal Equalizing Interior Water-Based Primer
Sealer 1070-1200
®
b. Sherwin Williams
Prep Rite High Build Interior-Latex Primer Surfacer
c. Hamilton Prep Coat Plus
®
d. Dursystem
e. Variance Omnicoat
Spray-Plast Wall Surfacer
Acrylic Finish
Critical (Severe) Lighting Areas and Gloss Paints
When using gloss, semi-gloss or enamel paint, or when working in a critical (severe)
®
lighting area, always finish DensArmor Plus
panels to a Level 5 finish as detailed in
GA 214. Critical lighting areas include but are not limited to walls and ceiling areas
near windows and skylights, long hallways and atriums with large surface areas exposed
to artificial and/or natural light. Refer to GA-214 for additional examples.
U.S.A.– Georgia-Pacific Gypsum LLC Canada – Georgia-Pacific Canada LP
Sales Information & Order Placement
U.S.A. Midwest: 1-800-876-4746
West: 1-800-824-7503 South: 1-800-327-2344 Northeast: 1-800-947-4497
CANADA Canada Toll Free: 1-800-387-6823
Quebec Toll Free: 1-800-361-0486
Technical Information
Georgia-Pacific Gypsum Technical Hotline U.S.A. and Canada: 1-800-225-6119 www.gpgypsum.com
TRADEMARKS DENSARMOR PLUS, BUILDING REPUTATIONS TOGETHER and the Georgia-Pacific logo are trademarks owned by or licensed to Georgia-Pacific Gypsum LLC. GRIPPER, GLIDDEN and PREP & PRIME are trademarks of The Glidden Company. SUPRIME is a trade mark of Pratt & Lambert United, Inc. DO IT BEST is a trademark of Do It Best Corp. SHERWIN WILLIAMS and BUILDERS SOLUTION are trademarks of SWIMC, Inc. MYTHIC is a trademark in the U.S. Patent and TM Office and in other countries, owned by Southern Diversified Products, LLC.
©2011 Georgia-Pacific Gypsum LLC. All rights reserved. Printed in the U.S.A. 9/11. GP-TM Lit. Item #531995.
* Please note that Georgia-Pacific Gypsum makes no warranty regarding the primers and surfacers identified above or the finishing results obtained by such products. As indicated, a mock up or test wall should be used to ensure the proposed decorative finish will produce an acceptable result. For further information regarding finishing of DensArmor Plus interior panels, please see Georgia-Pacific Gypsum’s Technical Guide for such panels available at www.gpgypsum.com.
Dursystem is a registered trademark of Tool World, Inc.Omnicoat is a trademark of Variance Acrylic Finishes, LLC.
WARRANTIES, REMEDIES AND TERMS OF SALE For current warranty information for this
product, please go to www.gpgypsum.com and select the product for warranty information. All sales of this product by Georgia-Pacific are subject to our Terms of Sale available at www.gpgypsum.com.
UPDATES AND CURRENT INFORMATION The information in this document may change without notice. Visit our website at www.gpgypsum. com for updates and current information.
CAUTION For product fire, safety and use information, go to www.gp.com/safetyinfo or call 1-800-225-6119.
HANDLING AND USE–CAUTION This product
contains fiberglass facings which may cause skin irritation. Dust and fibers produced during the handling and installation of the product may cause
breathing dust and minimize contact with skin and eyes. Wear long sleeve shirts, long pants and eye protection. Always maintain adequate ventilation. Use a dust mask or NIOSH/MSHA approved respirator as appropriate in dusty or poorly ventilated areas.
FIRE SAFETY CAUTION Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain fire rated assemblies/systems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fire resistance, two-hour fire resistance, or any other specified fire resistance or protection in an actual fire. In the event of an actual fire, you should immediately take any and all actions necessary for your safety and the safety of others without regard for any fire rating of any product or assembly/system.
skin, eye and respiratory tract irritation. Avoid
Loading...