Gennum Corporation GS3034 Datasheet

GS3034 - DATA SHEET
Revision Date: December 1998
Linear Class H
CIC Size Hybrid
FEATURES
• complete linear system
• current mode class H output stage
• current drive power amp
• low amplifier current 190
µA typical
• small size for CIC applications
STANDARD PACKAGING
• Hybrid Typical Dimensions (0.180in x 0.075in x 0.055in) (4.57mm x 1.91mm x 1.40mm)
• Hybrid View
DESCRIPTION
The GS3034 hybrid offers Gennum’s new innovative class H output stage along with two low noise inverting preamplifiers, in a CIC size package.
This new breed of output stage adapts the bias current of the receiver to the user's listening environment. In relatively loud environments the receiver will be fully biased similar to a traditional class A amplifier. However, as the loudness of the environment decreases, the bias current of the receiver adjusts to a minimum level required to cleanly pass the signal. At the same time the system maintains adequate “headroom” should the amplitude of the signal suddenly increase. By adapting the bias of the output stage to the requirements of the signal being processed, significant current savings can be realized compared to traditional class A amplifiers.
The rate at which the bias adapts is associated with a capacitor connected from pad CC of the hybrid to ground. For optimum performance it is recommended that a 0.22 µF capacitor be used.
The two low noise preamplifiers Stage A and Stage B, can be used as Volume Control and Gain Trim elements or Stage A as a filter shaping element and Stage B as the Volume Control. As the output stage is current drive, frequency shaping is relatively easy via the addition of a capacitor across the receiver.
V
REG
V
REG
GND
IN
B
OUT
B
IN
A
OUT
A
IN
R
E
V
B
CC
B
RIN
OUT
-
A
C1
170
24k
12k
­C2 0
µ1
CONTROL
REGULATOR
V
B
V
B
C3 0µ1
12k
B
+
-
+
-
C
0µ1
C4
15n
GS3034
10
5
9
8
3
2
112
11
7
6
4
All resistors in ohms, all capacitors in farads unless otherwise stated.
FUNCTIONAL BLOCK DIAGRAM
Document No. 521 - 51 - 04
GENNUM CORPORATION P.O. Box 489, Stn. A, Burlington, Ontario, Canada L7R 3Y3 tel. +1 (905) 632-2996
Web Site: www.gennum.com E-mail: hipinfo@gennum.com
2
521 - 51 - 04
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS OVERALL
Amplifier Current I
AMP
80 190 300 µA
Minimum Operating Voltage V
B
- - 1.1 V
Overall Gain A
V
44 47 50 dB
Distortion THD V
IN
= -40 dBV - 0.2 1 %
R
GT
= R
VC =
10 k
Input Referred Noise IRN A Weighted Filter - - 2.5 µVRMS
VOLTAGE REGULATOR
Regulator Voltage V
REG
I
LOAD
= 30 µA 870 920 970 mVDC
Output Noise A Weighted Filter - 2.9 - µVRMS
STAGE A and STAGE B
Input Bias Current I
BIAS
R
VC
= R
GT =
1 M -25 0 25 nA
DC Voltage Gain Stage A A
OL -A
38 52 - dB
Stage B A
OL -B
30 40 - dB
Current Source Capabilities I
SOURCE
15 30 - µA
Output Voltage Swing - Low V
SINK
200 280 - mV
STAGE C & CONTROL CIRCUIT
Maximum Current Sinking I
SINK
RE grounded, V
OUT
= 1.3 V 3 6 - mA
Output Impedance R
OUT
20 24 - k
Minimum Emitter Voltage V
RE-MIN
25 9mV
Maximum Emitter Voltage V
RE-MAX
68 73 80 mV
Minimum Transducer Current I
T-MIN
22050µA
Maximum Transducer Current I
T-MAX
300 400 500 µA
Maximum/Minimum Transducer I
RANGE
15 28 - dB
Current Ratio Dynamic Headroom Headroom Note 1 14 17 22 dB
Time Constant T
C
C
CC
= 0.22µF - 130 - mS
All parameters and switches remain as shown in the Test Circuit unless otherwise stated in CONDITIONS column.
PAD CONNECTION
CAUTION
CLASS 1 ESD SENSITIVITY
ABSOLUTE MAXIMUM RATINGS
PARAMETER VALUE / UNITS
Supply Voltage 5 VDC Power Dissipation 25 mW Operating Temperature Range -10° C to 40° C Storage Temperature Range -20° C to 70° C
Conditions: Frequency = 5 kHz, Temperature 25 °C, Voltage Supply = 1.3 VDC
ELECTRICAL CHARACTERISTICS
Notes: 1. Headroom = 20 Log (V
RE DC
/ V
REACRMS
) [VIN
=
-79 dBV]
12
1110
9
8
7
6
5
4
3
2
1
B
OUT
GND
V
REG
IN BR
IN
B
IN
RE
A
OUT
A
IN
V
B
OUT
CC