V
B
OUT
V
REG
IN
GND
SDA
B
OUT
B
0µ1
0µ2
C1
GM3036
C2
C4
C3
0µ1
0µ1
0µ1
0µ2
10n
R2 49k5
R3
R4
R6
R5
PGI
1
SLOW
AVERAGE
DETECTOR
FAST
AVERAGE
DETECTOR
CONTROL
10k
RECTIFIER
V
B
3k3
REGULATOR
48k
48k
11k
1M
2M
13k1
12k
1
X
- B
- A
- C
24 dB / Oct
BAND SPLIT
FILTER
High Frequency
Expander / Compressor
Low Frequency
Expander / Compressor
R
AGC_IN
R
H
R
L
R
LO
R
4:1
1:1
C
SAD
MPO
R
TH
B
OUT
B
R
FC
F
OUT
A
OUT
REC
OUT
C
FAD
V
BAT
V
REG
IN
GND
2
3
4
5
6
7
8
R1
R7
C5
C6
C7
69k5
100k
200k
200k
500k200k
DATA SHEET
GM3036 Programmable
DynamEQ®II Hybrid
FEATURES
DynamEQ
®
II flexibility
six programmable parameters
24 dB/oct state variable filter
twin average detectors
handles high input levels
drives class D integrated receivers
STANDARD PACKAGING
Hybrid typical dimensions:
0.209 in x 0.125 in x 0.100 in (5.31 mm x 3.18 mm x 2.54 mm)
DESCRIPTION
The GM3036 programmable hybrid is composed of a DynamEQ®II Wide Dynamic Range Compression signal processor and the GP522 controller memory chip. The hybrid incorporates 24 dB/oct filtering.
The gain and frequency response are dependent on the user’s environment. The Twin Average Detector circuit is optimized for sound quality during normal listening without sacrificing comfort during sudden loud sounds.
The GM3036 features six programmable parameters: independent compression ratio adjustment in the High and Low frequency channels, VC adjustment, threshold adjustment, crossover frequency adjustment and MPO adjustment.
The output stage is designed as a preamplifier for the class D integrated receiver.
BLOCK DIAGRAM
All resistors in ohms, all capacitors in farads unless otherwise stated. * patent pending
Revision Date: September 2000
GENNUM CORPORATION P.O. Box 489, Stn. A, Burlington, Ontario, Canada L7R 3Y3 tel. +1 (905) 632-2996
Web Site: www.gennum.com E-mail: hipinfo@gennum.com
Document No. 521 - 74 - 05
GM3036
2
521 - 74 - 05
GM3036
SDA
V
B
OUT
B
OUT
B
IN
GND
V
REG
1
2
3
4
5
6
7
8
IN
CAUTION
ELECTROSTATIC
SENSITIVE DEVICES
DO NOT OPEN PACKAGES OR HANDLE
EXCEPT AT A STATIC-FREE WORKSTATION
ELECTRICAL CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS
PARAMETER VALUE
Supply Voltage 1.4VDC
Power Dissipation 25mW Operating Temperature Range -10°C to 40°C Storage Temperature Range -20°C to 70°C
PAD CONNECTION
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Hybrid Current I
AMP
- 395 580 µA
Minimum Voltage Vb 1.1 - - V Total Harmonic Distortion THD V
IN
= -40dBV at 1kHz - 0.6 1.0 %
THD with Maximum Allowable Input THD
M
V
IN
= -23dBV, Rvc = 47k -210%
Input Referred Noise IRN Aweighted filter - 3.0 - µV
RMS
Total System Gain A
V
V
IN
= -90dBV 45 48 51 dB
Regulator Voltage V
REG
I
LOAD
= 30µA 890 930 1000 mV
AGC
Lower Threshold TH
LO
-88.5 -84.5 -80.5 dBV
Upper Threshold TH
HI
-36 -32 -28 dBV
Compression Gain Range A Gain(-90dBVIN) -Gain(-30dBVIN) 37.5 40.5 43.5 dB System Gain in Compression A
60
V
IN
=-60dBV 26 29 32 dB
Min. Compression Ratio CMP
1 :1
VIN=3kHz, -60dBV to -40dBV, R3 - Tap 15; R6 - Tap 15 0.9 1.0 1.1 Ratio
Max. Comp. Ratio CMP
4 :1
VIN =3kHz, -60dBV to -40dBV, R3 - Tap 0; R6 - Tap 0 3.6 4.0 4.3 Ratio
Fast Average Detector Time Constant τ
FAST
-10-ms
Slow Average Detector Time Constant τ
SLOW
-200-ms
FILTER
Maximum Crossover Frequency ƒ
c_max
R1 - Tap 15 3.0 3.9 - kHz
Nominal Crossover Frequency ƒ
c_nom
R1 - Tap 8 1.5 1.9 2.3 kHz
Minimum Crossover Frequency ƒ
c_min
R1 - Tap 0 - 0.9 1.4 kHz
Filter Rolloff Rate - 24 - dB/oct
Conditions: Supply Voltage VB = 1.3 V, Frequency = 1 kHz, Temperature = 25°C. The programmable parameters are adjusted to the following set values unless otherwise specified. (MPO) R5 - Tap15; (TH) R2 - Tap 0; (FC) R1 - Tap 8; (HP) R6 - Tap 0; (LP) R3 - Tap 0; (VC) R4 - Tap 0, R7 - Tap 0.
3
521 - 74 - 05
GM3036
Fig. 1 Test Circuit
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
STAGE A and B ---
Open Loop Gain (B) A
OL_B
-52-dB
Input Impedance (A) R
IN
8 10.6 12 k
OUTPUT STAGE
Stage Gain A
C
VIN=-30dBV 7 9 11 dB
Max Output Level MPO VIN=-25dBV, R
VCEXT
=221k -20 -18 -16 dBV
MPO Range MPO R5 - Tap 15 to Tap 0, R
VCEXT
=221k 11.6 13.6 15.6 dB
Output Resistance R
OUT
-24-k
ELECTRICAL CHARACTERISTICS continued
Conditions: Supply Voltage VB = 1.3V, Frequency = 1kHz, Temperature = 25°C The programmable parameters are adjusted to the following set values unless otherwise specified. (MPO) R5 - Tap 15; (TH) R2 - Tap 0; (FC) R1 - Tap 8; (HP) R6 - Tap 0; (LP) R3 - Tap 0; (VC) R4 - Tap 0, R7 - Tap 0.
All conditions and parameters remain as shown in the Test Circuit unless otherwise specified in the CONDITIONS column.
7
50k
0µ1
0µ2
C1
GM3036
C2
C4
C3
0µ1
0µ1
0µ1
0µ2
2µ2
10n
R2 49k5
R3
R4
R6
R5
PGI
1
SLOW
AVERAGE
DETECTOR
FAST
AVERAGE
DETECTOR
CONTROL
10k
RECTIFIER
V
B
3k3
REGULATOR
48k
48k
11k
1M
2M
13k1
12k
3k9
1
X
- B
- A
- C
24 dB / Oct
BAND SPLIT
FILTER
High Frequency
Expander / Compressor
Low Frequency
Expander / Compressor
R
AGC_IN
R
H
R
L
R
LO
R
HI
4:1
1:1
C
SAD
MPO
R
TH
B
OUT
B
IN
R
FC
R
VC
F
OUT
A
OUT
REC
OUT
C
FAD
V
BAT
V
B
V
REG
IN
GND
2
3
4
5
6
7
8
R1
R7
C5
C6
C7
69k5
100k
200k
200k
500k
200k
116k
All resistors in ohms, all capacitors in microfarads, unless otherwise stated.