Check your ceiling where the power
head of your new unit will be mounted.
Plan how you will be mounting the power head.
It is possible that ceiling joists may not be in the
exact position needed with respect to the garage
door operator. In any case, it may be necessary
to add an additional bracket and fasteners (not
included with your new door operator kit).
Check the wail directly above the garage
door. The door operator's header bracket
must be securely fastened to this wall. Insure
that the structure will provide a strong mounting
location.
Check to see if the mounting location
for the Safe-T-Beam ® System (STB) is
clear from obstruction and has a wood
surface available for attaching the STB
brackets. The brackets may also be attached to
concrete if necessary but extra tools and special
fasteners (not supplied) will be required.
You need a 110-120 Volt power supply
available. If you plan to plug the unit into a
standard electrical outlet, is one available? The
outlet should be no more than about 3 feet from the
power head once it is mounted. (The cord is 4 ft, in
length.) SEE WARNING BELOW.
To avoid damage to your door and/or
operator, make sure you disable any door
locks prior to installing your operator.
Insure that your door is properly balanced
and moving freely. SEE WARNING BELOW.
s_"esws _;i_be th_"o_ 9h yo_ _"oc_:s Gene/3e_-:s e_"
Is your garage door made of
light-weight steel, aluminum, fiberglass
or glass panels? Additional support bracing
must be added to these type doors, If this is the
case, please contact the door distributor or
manufacturer so that they can furnish you with a
"bracing kit."
(NOT SHOWN) If your garage does not have
a separate entry door, you might want to
consider an emergency release kit (GER-2) for
installation on your garage door. See page 30.
/
36" POWER CORD
TO
120V GROUNDED
OUTLET
TYPICAL SECTIONAL DOOR iNSTALLATiON
SUPPORT
BRACKET
EXTENSION SPRING
OR
TORSION SPRING
ADDED
HEADER BRACKET
MOUNTING BOARD
BRACES
SAFE-T=BEAM®
OVERVIEW OF
POTENTIAL HAZARDS
Garagedoorsarelarge,heavyobjectsthatmovewiththehelpofsprings
underhightensionandelectricmotors.Sincemovingobjects,springsunder
tension,andelectricmotorscancauseinjuries,yoursafetyandthesafetyof
othersdependon youreadingtheinformationinthismanual.Ifyouhave
questionsordonotunderstandtheinformationpresented,callyournearest
servicerepresentative
Inthissectionandthosethatfollow,thewordsDanger,Warning,and
Cautionareusedtoemphasizeimportantsafetyinformation.
Theword:
_,DANGERmeansthatsevereinjuryordeathwill resultfromfailure
tofollowinstructions.
_,WARNINGmeansthatsevereinjuryor deathcanresultfromfailure
tofollowinstructions.
_.CAUTIONmeansthatpropertydamageorinjurycanresultfromfailure
tofollowinstruction.
Theword#,;OTli_isusedtoindicateimportantstepstobefollowed
orimportantconsiderations.
IMPORTANT
INSTALLATION
INSTRUCTIONS
Toreducethe riskof
severe injuryordeath:
1. READAND FOLLOWALLSAFETY,INSTALLATIONAND
OPERATIONINSTRUCTIONS.If you haveanyquestionsor
do notunderstandan instruction,callyourservice
representative.
2. Do Notinstalloperatoron animproperlybalanceddoor.An
improperlybalanceddoorcouldcausesevereinjury.Repairs
andadjustmentstocables,springassembly,andother
hardwaremustbemadebyatrainedservicepersonusing
propertoolsandinstructions.
3. Removeall ropesand disableall locksconnectedtothe door
beforeinstallingoperator.
4. Installdooroperator7feet or moreabovethe floor.Mountthe
emergencyreleaseknob6feetabovethefloor.
5. Do Notconnecttheoperatortothe sourceof poweruntil
instructedto doso.
6. Locatethe controlbutton:
• Withinsightof door.
• Ata minimumheightof 5feet,so smallchildrencannot
reachit.
. Awayfromall movingpartsofthedoor.
InstalltheentrapmentWARNINGlabelnextto thewallbuttonor
console.Installthe emergencyreleasetag on,or nextto, the
emergencyrelease
Theoperatormustreversewhenthedoorcontactsa 1-1/2inch
highobjecton theflooratthe centerof thedoorway.Thisis about
thesizeofa 2" x 4" boardlaidflat.
Safe-T-Beam ® (STB) Non-Contact Reversing System
Places an invisible beam across door opening that reverses the door during down travel to the fully open
position if anything passes through beam.
Safe-T-Reverse ® Contact Reversing System
Automatically stops and reverses a closing door within 2 seconds of contact with an object.
Safe-T-Stop ® Timed Reversed System
Automatically opens a closing door, if door does not close within 30 seconds.
Force Guard ® Control
Used to set the force required for opening and closing door. For maximum safety, set the minimum force
required to fully open and close door.
Automatic Lighting System
One or two light bulbs (depending on model) up to 100 Watts max. each are used for safer entries and exits.
The light turns on when door is activated and automatically turns off 4.5 minutes later.
Manual Emergency Release
Allows the garage door to be opened or closed manually for emergencies or maintenance.
_ Immmm
@
@
@
FASTENERS - Shown full size. See Parts List for description.
Bolt, #10-24 x 1/2"
--'m
Bolt, 5/16"-18 x 1/2"
Phillips Hex Head Screw, No. 10 x 1-1/4"
Self-Drilling Screw
Bolt, 3/8"-16 x 7/8"
1/4"-20 x 3/4"
remotes
vary by model
i!_L _ _ ,, . :i : i_:L:,_I
, _ "., !i¸¸ _ :Lui
@
Insulated Staple
Pan Head Screw #6 x 1-1/4"
Pan Head
Phillips Screw
No. 8 x 5/8"
Ii
aa _ _ D
Lag Screw, 1/4" x 2" Clevis Pin No. 8 x 3/4"
Speed Nut Cotter Pin
m
Z
Cold Head Pin
Hex Head Screw