Check your ceiling where the power
head of your new unit will be mounted.
Plan how you will be mounting the power head. It is possible that ceiling joists may not be in the
exact position needed with respect to the garage door operator. In any case, it may be necessary
to add an additional bracket and fasteners (not
Check the wail directly above the garage
door. The door operator's header bracket
must be securely fastened to this wall. Insure
that the structure will provide a strong mounting
location.
Check to see if the mounting location
for the Safe-T-Beam ® System (STB) is
clear from obstruction and has a wood
surface available for attaching the STB
brackets. The brackets may also be attached to concrete if necessary but extra tools and special
fasteners (not supplied) will be required.
You need a 110-120 Volt power supply
available. If you plan to plug the unit into a standard electrical outlet, is one available? The outlet should be no more than about 3 feet from the
power head once it is mounted. (The cord is 4 ft, in length.) SEE WARNING BELOW.
To avoid damage to your door and/or
operator, make sure you disable any door locks prior to installing your operator.
Insure that your door is properly balanced
and moving freely. SEE WARNING BELOW.
s_"esws _;i_be th_"o_ 9h yo_ _"oc_:s Gene/3e_-:s e_"
Is your garage door made of
light-weight steel, aluminum, fiberglass
or glass panels? Additional support bracing must be added to these type doors, If this is the
case, please contact the door distributor or manufacturer so that they can furnish you with a
"bracing kit."
(NOT SHOWN) If your garage does not have
a separate entry door, you might want to
consider an emergency release kit (GER-2) for installation on your garage door. See page 30.
/
36" POWER CORD
TO
120V GROUNDED
OUTLET
TYPICAL SECTIONAL DOOR iNSTALLATiON
SUPPORT BRACKET
EXTENSION SPRING
OR
TORSION SPRING
ADDED HEADER BRACKET MOUNTING BOARD
BRACES
SAFE-T=BEAM®
OVERVIEW OF
POTENTIAL HAZARDS
Garagedoorsarelarge,heavyobjectsthatmovewiththehelpofsprings underhightensionandelectricmotors.Sincemovingobjects,springsunder tension,andelectricmotorscancauseinjuries,yoursafetyandthesafetyof othersdependon youreadingtheinformationinthismanual.Ifyouhave questionsordonotunderstandtheinformationpresented,callyournearest servicerepresentative
Inthissectionandthosethatfollow,thewordsDanger,Warning,and Cautionareusedtoemphasizeimportantsafetyinformation.
Theword:
_,DANGERmeansthatsevereinjuryordeathwill resultfromfailure
tofollowinstructions.
_,WARNINGmeansthatsevereinjuryor deathcanresultfromfailure
tofollowinstructions.
_.CAUTIONmeansthatpropertydamageorinjurycanresultfromfailure
tofollowinstruction.
Theword#,;OTli_isusedtoindicateimportantstepstobefollowed orimportantconsiderations.
IMPORTANT
INSTALLATION
INSTRUCTIONS
Toreducethe riskof
severe injuryordeath:
1. READAND FOLLOWALLSAFETY,INSTALLATIONAND OPERATIONINSTRUCTIONS.If you haveanyquestionsor
do notunderstandan instruction,callyourservice representative.
2. Do Notinstalloperatoron animproperlybalanceddoor.An improperlybalanceddoorcouldcausesevereinjury.Repairs andadjustmentstocables,springassembly,andother hardwaremustbemadebyatrainedservicepersonusing propertoolsandinstructions.
3. Removeall ropesand disableall locksconnectedtothe door beforeinstallingoperator.
4. Installdooroperator7feet or moreabovethe floor.Mountthe emergencyreleaseknob6feetabovethefloor.
5. Do Notconnecttheoperatortothe sourceof poweruntil instructedto doso.
6. Locatethe controlbutton:
Withinsightof door.
Ata minimumheightof 5feet,so smallchildrencannot
reachit.
. Awayfromall movingpartsofthedoor. InstalltheentrapmentWARNINGlabelnextto thewallbuttonor
console.Installthe emergencyreleasetag on,or nextto, the emergencyrelease
Theoperatormustreversewhenthedoorcontactsa 1-1/2inch highobjecton theflooratthe centerof thedoorway.Thisis about
thesizeofa 2" x 4" boardlaidflat.
Safe-T-Beam ® (STB) Non-Contact Reversing System Places an invisible beam across door opening that reverses the door during down travel to the fully open
position if anything passes through beam. Safe-T-Reverse ® Contact Reversing System
Automatically stops and reverses a closing door within 2 seconds of contact with an object.
Safe-T-Stop ® Timed Reversed System
Automatically opens a closing door, if door does not close within 30 seconds.
Force Guard ® Control Used to set the force required for opening and closing door. For maximum safety, set the minimum force
required to fully open and close door.
Automatic Lighting System
One or two light bulbs (depending on model) up to 100 Watts max. each are used for safer entries and exits. The light turns on when door is activated and automatically turns off 4.5 minutes later.
Manual Emergency Release
Allows the garage door to be opened or closed manually for emergencies or maintenance.
_ Immmm
@
@
@
FASTENERS - Shown full size. See Parts List for description.
Bolt, #10-24 x 1/2"
--'m
Bolt, 5/16"-18 x 1/2"
Phillips Hex Head Screw, No. 10 x 1-1/4"
Self-Drilling Screw
Bolt, 3/8"-16 x 7/8"
1/4"-20 x 3/4"
remotes
vary by model
i!_L _ _ ,, . :i : i_:L:,_I
, _ "., !i¸¸ _ :Lui
@
Insulated Staple
Pan Head Screw #6 x 1-1/4"
Pan Head
Phillips Screw
No. 8 x 5/8"
Ii
aa _ _ D
Lag Screw, 1/4" x 2" Clevis Pin No. 8 x 3/4"
Speed Nut Cotter Pin
m
Z
Cold Head Pin
Hex Head Screw
Loading...
+ 22 hidden pages