Genie NEMA4, NEMA4X Installation Supplement Manual

112123.500423
NOT F O R RESIDENTIAL USE
This supplement instruction is to be used in combination with the standard accompanying GCL™ Installation Manual. This supplement contains NEMA 4 & 4X wiring instructions and an illustrated parts breakdown which specifies parts included in the NEMA 4 & 4X GCL™ series of operators. When installing a NEMA 4 or 4X operator, liquid tight conduit and fittings must be used. Refer to NEC and local building codes for wiring and conduit requirements.
IMPORTANT: Prior to installing or operating an GCL™ NEMA 4 or 4X Operator, carefully read the GCL™ Installation Manual
NEMA 4 & 4X
INSTALLATION SUPPLEMENT ANY TYPE GCL™ COMMERCIAL-INDUSTRIAL DOOR
OPERATOR CAN BE ORDERED AS A NEMA 4 OR 4X VERSION.
8-12
1.1
www.geniecompany.com
GCL
THIS PAGE LEFT BLANK
Make
8-12
www.geniecompany.com
GCL
1
Line Voltage Wiring Fig. 1
WARNING
DO NOT apply power to operator until instructed to do so.
Overhead Door Corporation recommends that line voltage wiring be performed by a qualified electrician.
Be sure that electrical power has been disconnected from the
input power wires being connected to the operator prior to
handling these wires. An appropriate lock-out /tag-out procedure is recommended.
Line voltage wiring must meet all local building codes.
sure operator voltage, phase and frequency nameplate
ratings are identical to the job site line voltage ratings.
Input power wiring must be properly sized for the operators
amperage rating located on the nameplate.
To reduce the risk of electric shock, make sure the chassis of this unit is properly grounded.
1) Remove LINE VOLTAGE INPUT PLUG and install proper fittings and 1/2”conduit.
2) Route proper LINE VOLTAGE wires into operator.
3) Locate LINE INPUT terminals on circuit board. Using
terminal.
NOTE: LIQUID-TIGHT CONDUIT AND FITTINGS ARE NOT PROVIDED
HIGH VOLTAGE INPUT PLUGS (Right & Left)
Optional Accessory Modules
Optional Additional Transformer
LINE INPUT TERMINALS
LINE GROUND
208/240V 480/575V
LINE INPUT TERMINALS
LINE GROUND
ROUTE HIGH VOLTAGE WIRING IN THE SHADED AREA AS SHOWN
HIGH VOLTAGE INPUT PLUGS (Right & Left)
L1/L1
N/L2
GND
POWER CONNECTIONS
LINE IN
POWER CONNECTIONS
LINE (HOT)
NEUTRAL
LINE 1
LINE 2
L1
L2
GND
LINE 1
LINE 2 LINE 3
L3
Three Phase
Single Phase
Optional Additional Transformer
115V
208V 230V
ROUTE HIGH VOLTAGE WIRING IN THE SHADED AREA AS SHOWN
Figure 1
(SUPPLEMENT TO SECTION 5 OF THE ACCOMPANYING GCL™ INSTALLATION MANUAL)
High Voltage Wiring