The design and specifications are subject to change without prior notice
for product improvement. Consult with the sales agency or manufacturer
for details.
AIR CONDITIONER
REMOTE CONTROLLER ILLUSTRATION
CR142-R51G(H)
202055091488
Thank you very much for purchasing our air conditioner.
Please read this owner's manual carefully before using
your air conditioner.
Remote Controller Specifications
CONTENTS
Remote controller Specifications...................................................
Operation of buttons .................. ..................................................
Indicators on LCD ..........................................................................
How to use the buttons .................................................................
Auto operation.................................................................................
Cooling/Heating/Fan operation......................................................
Dehumidifying operation ...............................................................
Timer operation...............................................................................
Handling the remote controller ......................................................
12
Model
Rated Voltage
2
Signal Receiving
RG51G/E, RG51H/E
3.0V(Dry batteries R03/LR03 2)
8m
Range
3
Environment
-5 C 60C
~~
5
6
6
6
SET TEMPERATURE( C)
AUTO
COOL
DRY
HEAT
O
FAN
HIGH
MED
LOW
SET TEMPERATURE( C)
AUTO
COOL
DRY
HEAT
O
FAN
HIGH
MED
LOW
7
MODE
SWING
TEMP
ON/OFF
ECO
RESET LOCK
DO NOT
DISTURB
FAN /SILENCE
TIMER ON
TIMER OFF
TURBO
8
MODE
SWING
TEMP
ON/OFF
SLEEP
RESET LOCK
DO NOT
DISTURB
FAN /SILENCE
TIMER ON
TIMER OFF
TURBO
RG51G/E
NOTE:
Buttons design is based on typical model and might be slightly different from the
RG51H/E
actual one you purchased the actual shape shall prevail.
All the functions described are accomplished by the unit. If the unit has no this
feature, there is no corresponding operation happened when press the relative
button on the remote controller.
When there are wide differences between Remote controller Illustration and
, ,
USER'S MANUAL on function description, the description of USER'S
MANUAL shall prevail.
,,
,,
11
,,
,,
, ,
22
Operation of buttons
TEMP
O
FAN
HIGH
MED
LOW
SET TEMPERATURE( C)
AUTO
COOL
DRY
HEAT
2
ON/OFF
ECO
RESET LOCK
DO NOT
DISTURB
FAN /SILENCE
TIMER ON
TIMER OFF
TURBO
3
MODE
SWING
4
5
6
7
RG51G/E
11
12
13
10
TEMP UP Button
1
Push this button to increase the indoor temperature setting in 1 C increments to 30 C.
TEMP DOWN Button
2
Push this button to decrease the indoor temperature setting in 1 C increments to 17 C.
OO
OO
NOTE Temperature contol is not available
in Fan mode.
3
MODE Button
Press this button to modify the air conditioner
1
8
9
mode in a sequence of following:
AUTO
COOL
DRY
HEAT FAN
NOTE Please do not select HEAT mode if the
machine you purchased is cooling only type.
Heat mode is not supported by the cooling
only appliance.
SWING Button
4
Used to stop or start horizontal louver movement or set the desired up/down air flow
direction. The louver changes 6 degree in
angle for each press. If keep pushing more
than 2 seconds, the louver will swing up and
down automatically.
ECO Button(applicalbe for RG51G/E):
5
Used to enter the energy efficient mode.
Under cooling mode, press this button, the
remote controller will adjust the temperature
automatically to 24 C, fan speed of Auto to
save energy(but only if the set temperature
is less than 24 C). If the set temperature is
between 24 C and 30 C, press the ECO
O
O
OO
button, the fan speed will change to Auto,
the set temperature will remain unchanged.
NOTE:
Pressing the TURBO and SLEEP button,
modifying the mode or adjusting the set
temperature to less than 24 C will stop
O
ECO operation.
Under ECO operation, the set temperature
should be 24 C or more. it may result in
O
insufficient cooling. If you feel uncomfortable,
just press the ECO button again to stop it.
Operation of buttons
SET TEMPERATURE( C)
AUTO
COOL
DRY
HEAT
O
TEMP
1
ON/OFF
3
MODE
SWING
4
5
6
SLEEP
RESET LOCK
DO NOT
DISTURB
FAN /SILENCE
TIMER ON
TIMER OFF
TURBO
7
RG51H/E
FAN
HIGH
MED
LOW
11
12
13
10
SLEEP Button(applicable for RG51H/E):
Active/Disable sleep function. It can
maintain the most comfortable temperature and save energy. This function is
available on COOL, HEAT or AUTO
mode only .
For the details, please see sleep
operation in USER S MANUAL.
,,
,,
,,
,
,,
NOTE: While the unit is running under
SLEEP mode, it would be cancelled if
MODE, FAN SPEED or ON/OFF button
is pressed.
2
8
9
6
RESET Button
Once the recessed RESET button is pressed,
all of the current settings will be cancelled and
the controller will return to the initial settings.
DO NOT DISTURB Button
7
Press this button to turn off the indoor screen
display, and also turn off the Air conditioner
buzzer, the fan speed shifts to low, which
create a comfortable and quiet environment.
Press it again to cancel this function.
Under DO NOT DISTURB mode, the display
will illuminate for 10 seconds while adjusting
the mode, set temperature or fan speed, etc.
8
ON/OFF Button
Operation starts when this button is pressed
and stops when the button is pressed again.
9
FAN/SILENCEC Button
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
If pushing more than 2 seconds, the Silence
function will be activated, pushing more than
2 seconds again to disable.
When the Silence function is activated, the
compressor will operate at low frequency
and the indoor unit will bring faint breeze,
which will reduce the noise to the lowest
level and creat a quiet and comfortable
room for you. Due to low frequency operation
of compressor, it may result in insufficient
cooling and heating capacity.