Generic BHT-1000 User Manual

ModelBHT-1000
Heating Room Thermostat
User Guide
Welcome
Thank you for your purchase.
Thermostat Screws Installation/programming manual Wall plate
Your thermostat carries an 18 month warranty from date of purchase. Service outwith the warranty period may incur a charge.
Contents
Warranty
Your thermostat
Features
Simple installation Acrylic face plate Large, backlit display Sleek, contemporary design Elegant chrome frame Feather touch control panel 5+2 six period per day programming Simple, one-touch temperature control over-ride. Pre-set temperatures maintained within +/- 1°C Internal and external sensors allow control of both air and/or floor temperatures Suitable for installation in a standard single pattress box or European 60mm round box RS485/MODBUS communication optional
Home screen quick reference
Operation/programming
1. Power on/off
Press to turn on/off.
2. Adjusting/setting the temperature
Press to set the desired temperature.
3. Adjusting/Setting the clock
5.Adjusting/setting the program schedules
The BHT-1000 range has been developed to control electric underfloor or water heating systems. These units are designed for use in commercial, industrial, civil and domestic properties.
Power Up DownClock
Mode
Time Timing on/off
AM/PM
Room Temp.
Set Temp.
Manual
Lock
Period
Floor Temp.
Heating On
Programmable
Temp.Week
Technical Data
SensorNTC Accuracy±1
Power Consumption< 1.5W Timing Error<1 Power Supply95 ~ 240VAC, 50 ~60Hz Current Load3Awater heating), 16A(electric heating) Shell materialPC+ABS (flame retardant) Dimension86x86x13.3mm Ambient Temp.0-45℃,5-95RH Non-condensing Storage Temp.-5-55 Installation Hole distance: 60mm
Set Temp. Range5-35 Room Temp. Range5-99
Your new thermostat will provide uniform and comfortable temperature control throughout every room in your property. We bring together technology, craftsmanship and the highest quality materials to provide you with a safe, reliable product combined with sleek, contemporary design. Please read this installation/programming manual for comprehensive instructions on installing and operating your thermostat. Please ensure a suitably qualified person installs your thermostat and complies with all local regulations.
2.5m External (Floor) Sensor
1pc 1pc
1pc 1pc
1pc
Touch the icon to set minute, hour and weekday (1 = Monday, 2 = Tuesday etc.) by using the arrows. Press once more to confirm and exit.
4.Locking your thermostat
Press and hold the and arrows for 5 seconds to lock/unlock your thermostat.
Your thermostat provides six scheduled heating periods each day – three Comfort periods - 1, 3 & 5 (the temperature required when room is occupied) and three Economy periods – 2, 4 & 6 (the temperature required when room is unoccupied). You can set both the time and temperature for each of these six daily periods. Adjusting/setting the schedules can only be carried out when in program mode; Touch M (mode) to change between manual mode and programme mode. In manual mode,
Eco-Term sp. z o.o. ul. Mały Płaszów 10 30-720 Kraków www.eco-term.eu
Eco-Term Group s.r.o Orgovánová 2 917 02 Trnava www.eco-term.net
Installing your thermostat
6. System function settings
With power off, press and hold both M and for 5 seconds to enter the System Functions. Press M to scroll through the available functions, and use the and arrows to change the available options. Your thermostat will automatically exit the System Functions settings after approximately 15 - 20 seconds of inactivity. All settings are automatically
Wiring your thermostat
Wiring your thermostat
Please note:
1.“Err” on your thermostat indicates a fault without the external (floor) sensor. Your thermostat will be inoperative until the error is rectified.
2. When sensor selection is “AL” (option 3 above) the room temperature will be displayed on your thermostat by default. The floor temperature can be displayed temporarily by pressing the button for three seconds. Your thermostat will revert to display the room temperature after several seconds.
Your thermostat is suitable for installation within a standard 86mm pattress box or European 60mm
round pattress box.
will show in the bottom left of the screen. Touch and hold the icon until the weekday schedule settings appear (1 2 3 4 5 will show along the top of the screen). Use the and arrows to adjust the time for the 1st (Comfort) period
Press the icon and use the and arrows to set the temperature for the 1st period. Repeat this process for periods 2 – 6. Press the icon once more to enter the weekend schedule settings (6 & 7 will show along the top of the screen). Repeat the above process to set the weekend schedule. Press once more to confirm and exit.
Default settings for program schedule
Time display
WEEKDAY (MON. – FRI.)
WEEKEND (SAT. – SUN.)
TIME
TEMP.
TIME
TEMP.
Period 1 (Comfort)
06.00 waken
20°C
06.00 waken
20°C
Period 2 (Economy)
08.00 leave
15°C
08.00 leave
20°C
Period 3 (Comfort)
11.30 home
15°C
11.30 home
20°C
Period 4 (Economy)
13.30 leave
15°C
13.30 leave
20°C
Period 5 (Comfort)
17.00 home
22°C
17.00 home
°C
Period 6 (Economy)
22.00 bed
15°C
22.00 bed
15°C
15
Default settings above assume a 5+2 (day) weekly program.
Please note:
Do not over-tighten the terminals in your thermostat as damage may occur.
Code Function Setting & options Default
1
Air temperature
calibration
Range is -9°C to +9°C for internal sensor -2
2
Switching differential
Range is 0°C to 5°C
The number of degrees above/below set temperature before switching on/off When default is set to 1°C the thermostat will switch on 0.5°C below the set temperature and will switch off 0.5°C above the
set temperature.
1
3 Button locking
00: = All buttons will lock except the Power button 01: = All buttons will lock
01
4 Sensor selection
In = control temperature using the internal sensor
Ou = control temperature using the external (floor) sensor Al = control temperature using internal sensor to control temperature, and external sensor to limit the floor temperature Remark: Please make sure the right sensor. If choose the
wrong or bad one, LCD will display Err.
In for GA Al for GB
5
Minimum
temperature setting
Range is 5°C - 15°C.
5
6
Maximum
temperature setting
Range is 15°C - 45°C.
35
7 12/24 hour clock
00: 12h: = 12 Hour clock 01: 24h: = 24 hour clock
01
8
Display Mode
00display both set temp. and room temp. 01display set temp. only
00
9
Minimum floor
temperature
protection setting
Range is 0°C - 20°C.
When chosen floor temperature is reached, the system will automatically switch off. This facility is used to protect delicate
floor coverings.
0
A
Maximum floor
temperature
protection setting
Range is 10°C - 70°C.
When chosen floor temperature is reached, the system will automatically switch off. This facility is used to protect delicate
floor coverings.
26
B Backlight On Time 3-99S. 10
C
Return to factory
setting
00: Normal Status 01:Return to factory setting
00
1
5
AC95~230V
IP20
N
L
1
2
3
4
M
Close Open
5
6
NTC
GA
L1
N1
LOAD
IP20
N
L
1
2
3
4
NTC
5
6
GB
AC95~230V
GA for water heating and GB for electric heating; External Sensor is optional. The electrical connections can be made only by a certified electrician.
Step 1. Keep power off. See Fig 1.
Fig 1
Step 2. Remove the mounting Plate. See Fig 2.
Fig 2
Step 3. Connect power supply, load and external (floor) sensor into the appropriate terminals if there is external sensor. (see “Wiring your thermostat” for details and Fig 3).
Fig 3
Step 4. Fix the mounting plate into the wall with screws in the box. See Fig 4
Fig 4
Step 5. Fasten body of thermostat and the mounting plate through the groove. See Fig 5.
Fig 5
Step 6. Installation complete. See Fig 6.
Fig 6
RISK OF ELECTRICAL SHOCK.
Disconnect/isolate
power supply prior to making electrical connections. Contact with high voltage components can cause electrical shock, severe injury or death.
Orgovánová 2 917 02 Trnava www.eco-term.net
Eco-Term sp. z o.o. ul. Mały Płaszów 10 30-720 Kraków www.eco-term.eu
Eco-Term Group s.r.o Orgovánová 2 917 02 Trnava www.eco-term.net
made in China