General Tools & Instruments IRT659K Instruction Manual

12:1 INFRARED THERMOMETER with “K” TYPE THERMOCOUPLE
& ADJUSTABLE EMISSIVITY
USER’S MANUAL
IRT659K
Please read this manual carefully and thoroughly before using this product.
TABLE OF CONTENTS
Key Features & Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
What’s in the Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Setup Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Install Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 – 11
Using the IRT to Scan for Temperature . . . . . . . . . . . . . . . 6 –7
Choosing an IRT Display Mode . . . . . . . . . . . . . . . . . . . . . 7 –8
Adjusting Emissivity and Setting Temperature Alarms . . 8 – 10
Recalling Logged Measurements . . . . . . . . . . . . . . . . . . . . . . 10
Using the “K” Type Probe to Measure Temperature . . . 10 – 11
Full Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 – 12
Operating & Maintenance Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Return for Repair Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 – 15
INTRODUCTION
Thank you for purchasing General Tools & Instruments’ (General’s) IRT659K 12:1 Infrared Thermometer with “K” Type Thermocouple & Adjustable Emissivity. Please read this manual carefully and thoroughly before using the thermometer.
2
The IRT659K can measure surface temperature using either of two methods: non-contact (using an IR thermometer with a laser pointer) or contact (using a “K” type thermocouple). A “K” type thermocouple with a wide measurement range is included in the package. The instrument automatically stores its last 10 IR readings in a nonvolatile memory for later recall in reverse chronological order. During a single scanning session, the IRT659K simultaneously displays real-time measurements on a main readout and the maximum, minimum, average or largest difference between measurements during that session on a smaller readout.
The IRT659K and “K” type thermocouple, a “9V” battery and this user’s manual are sold together with a nylon pouch in a blister pack.
KEY FEATURES & SPECIFICATIONS
• 12:1 distance-to-spot (D:S) ratio
• -58° to 1202°F (-50° to 650°C) IRT measurement range
• -146° to 2498°F (-99° to 1370°C) “K” type thermocouple measurement range; included thermocouple has 0° to 500°F (-18° to 260°C) range
• Backlit 1.5 in. (38.1mm) diagonal LCD
• IRT measurement accuracy of ±3°F (2°C) or ±2% of reading (whichever is greater) above 32°F (0°C)
• Automatically holds measurements
• Automatically stores last 10 readings for recall
• Displays Min/Max/Avg/Dif temperatures captured during each scanning session
• Settable high and low temperature alarms
• °C/°F, laser pointer on/off and backlight on/off switches
• ½ second response time
• Emissivity is adjustable from 0.1 to 1.0 (in 0.01 steps), with default value of 0.95
• 30 second Auto Power Off
3
SAFETY INSTRUCTIONS
CAUTION!
The IRT659K is a Class II laser product that emits less than 3mW of radiation at a wavelength between 630 and 660nm. Avoid looking directly at the laser pointer. U.S. law prohibits pointing a laser beam at aircraft; doing so is punishable by a fine of up to $10,000 and imprisonment.
The laser may cause discomfort if viewed directly. Your eyes’ natural aversion reflex will prevent you from looking at the beam long enough to cause harm. As a precaution, keep the IRT659K out of the hands of children, especially if you have pets.
Never stare at the laser beam through binoculars or a magnifying glass. Do not operate the IRT in the presence of flammable or explosive gases or in
environments full of dust or static electricity. Do not operate the unit near a source of a strong electromagnetic field, such as
an arc welder or an induction heater. Be careful not to burn yourself when attaching the thermocouple probe to a hot
surface.
WHAT’S IN THE PACKAGE
The IRT659K comes in a blister pack along with a “9V” battery, a nylon pouch and this user’s manual. A wide temperature range “K” type thermocouple is inside the pouch.
4
PRODUCT OVERVIEW
Fig. 1 shows all controls, indicators, connectors and other physical features of the IRT659K. Fig. 2 shows all possible indications on the unit’s LCD. Familiarize yourself with the positions of all controls and connectors and the meaning of all display indications and icons before moving on to the Setup Instructions and Operating Instructions.
A. Laser pointer B. Infrared sensor C. Measurement trigger D. Battery compartment E. LCD F. MODE/SET button
LOG button
G. H. °F/°C
button
I. IR/K (TC) button
J. / button
K. “K” type thermocouple probe
(shown inserted in socket)
E
F
J
H
Fig. 1
G
A
B
K
I
C
D
A. Low temperature alarm setpoint exceeded B. High temperature alarm setpoint exceeded C. Operating in scanning mode D. Backlight on E. Laser pointer enabled F. Low battery G. Main readout H. Display mode indicators
I . “K” type thermocouple (TC)
measurement selected
J. Log # (01 to 10) K. Log value L. Display mode value M. Celsius unit N. Fahrenheit unit
AB
CDE
G
H
I
J
F
N
M
L
K
Fig. 2