FEATURES:
• New series for food, storage and general purposes
• Ultra low power consumption in shutdown mode
• Extended long time measuring reliability
• Laser sighting On/Off is switchable
• Backlit LCD display
• °F or °C selectable
• Electronic trigger lock
• Temperature data storage
• Audible alarms
APPLICATIONS:
• Manufacturing processes of semiconductor technology
• Food safety and processing
• Super low temperature science experiment
• HVAC energy audits
• Electrical troubleshooting
• Testing terminals on circuits
• Air conditioning
SAFETY INFORMATION:
Read the following safety
information carefully before attempting to operate or
service the meter. Only qualified personnel should
perform repairs or services not covered in this manual.
LASER WARNING NOTE!
• Do not point laser directly at eyes.
• Use caution around reflective surfaces.
• Keep out of reach of children!
CAUTIONS!
• DO NOT submerge the unit in the water.
• This product is not designed for use in medical
evaluations. The product can only be used to measure
body temperature for reference. It is meant for
industrial and scientific purposes.
SAFETY SYMBOLS
Dangerous, refer to this manual before using the
meter.
CE Certification
This instrument conforms to the following standards:
EN61326: Electrical equipment for measurement, control and
laboratory use.
IEC61000-4-2: Electrostatic discharge immunity test.
IEC61000-4-3: Radiated, radio-frequency, Electromagnetic
field immunity test.
IEC61000-4-8: Power frequency magnetic field immunity
test.
Tests were conducted using a frequency range of
80-1000MHz with the instrument in three orientations.
The average error for the three orientations is ±1.0 °F
(±0.5 °C) at 3V/m throughout the spectrum. However,
between 781-1000MHz at 3V/m, the instrument may not
meet its stated accuracy.
The device may not be disposed in the trash. It
promotes the re-use recycling and other forms of
recovery of used materials and components, and to improve
the environmental performance of all operators (manufacturers, traders, treatment facilities) involved in the life
cycle of products. Dispose of the product appropriately in
accordance with relevant regulations.
SPECIFICATIONS:
Distance/Spot Ratio: 12:1
Temperature Range: -58° to 600°F (-50° to 316°C)
Accuracy(@ ambient temperature of 77°F/25°C):
±5°F (±3°C) within -58° to -22°F (-50° to -30°C)
±3°F (±2°C) within -22° to 212°F (-30° to 100°C)
±2% within 212° to 600°F (100° to 316°C)
Thermopile: 8 ~ 14µm
Repeatability: ±2°F (±1°C)
Resolution: 0.1°F (0.1°C)
Response Time: 500 ms.
Operating Temperature: 32° to 122°F (0° to 50°C),
10 to 90%RH