General Tools General Tools IRT207 Manual

IRT207 Heat Seeker
General Tools & Instruments
GeneralToolsNYC
TM
Infrared Thermometer
1. Introduction
Congratulations on your purchase of the new IRT207 Heat Seeker an 8:1 non-contact temperature measuring instrument using infrared technology and laser sighting. Features include a 4 digit backlit LCD, scan/hold function and auto power off (7 secs). To measure a temperature, point the unit at the object, pull the measuring trigger and hold. Make sure the target area is larger than the unit’s spot size.
TM
InfraRed Thermometer (IRT). This IRT is
2. Safety Information
CAUTION: Use of controls or adjustments or
performance of procedures other than those specified herein may result in dangerous radiation exposure.
• DO NOT submerge the unit in water.
• This product is not designed for use in medical evaluations. The product can only be used to measure body temperature simply for reference. The IRT is meant for industrial and commercial uses.
LASER WARNING NOTE!
Do not point laser directly at eye. Use caution around reflective surfaces. Keep out of reach of children.
This instrument conforms to the following standards:
EN61326: Electrical equipment for measurement, control
and laboratory use. IEC61000-4-2: Electrostatic discharge immunity test. IEC61000-4-3: Radiated, radio-frequency,
electromagnetic field immunity test.
IEC61000-4-8: Power frequency magnetic field immunity
test.
Tests were conducted using a frequency range of 80-1000MHz with the instrument in three orientations. The average error for the three orientations is ±1.0ºF (±0.5ºC) at 3V/m throughout the spectrum. However, between 781-1000MHz at 3V/m, the instrument may not meet its stated accuracy.
Battery Low
Temperature Display
3. Specifications
Temperature Range -4º to 608ºF (-20º to 320ºC) Accuracy ±2% of reading or 3.6°F (2°C),
whichever is greater, above 32°F (0°C); ±2% of reading or 5.4°F (3°C),
whichever is greater, below 32°F Field of View 8:1 Laser Type, Class 2, <1mW @655nm
Output/Wavelength Repeatability ±1ºC (±1.8ºF) Response Time 500 ms. Operation Temp. 32º to 104ºF (0º to 40ºC) @ 10 to 90% RH Auto Power Off Automatically after 7 sec. Emissivity Fixed at 0.95 Storage Temp. 14º to 122ºF (-10º to 50ºC) ºF/ºC Switchable YES Battery Type “9V” battery (included) Battery Life 16 hrs Dimension 5.98 x 4.65 x 1.26 in. (152 x 118 x 32 mm) Weight 4.22 oz. (120g) without battery Accessory “9V” battery, Instruction manual
4. Operation of Instrument 4-1 Quick Start
To measure a temperature, point the unit at the target you want to measure, pull the trigger and hold. Move closer to or farther from the target until it appears about the same size as the laser’s circular measurement ‘spot’, which has a D:S ratio (Field of View) of 8:1. The single spot of laser is used for aiming purposes only.
The unit displays temperatures in either ºF or ºC. Replace the battery when the battery voltage drops
below the voltage for reliable operation and the low battery symbol appears.
Laser ON/OFF Indication
ºF/ºC Switch Indication
5. Maintenance
Cleaning the lens: Blow off loose particles using clean compressed air. Gently brush remaining debris away with a camel’s hair brush. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water.
Laser Certification Label (on side of unit)
SCAN
ºF/ºC Switch
HOLD
Laser ON/OFF Switch
NOTE:
DO NOT use solvents to clean the glass lens.
Cleaning the housing:
Use soap and water on a damp sponge or soft cloth.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176