General Tools General Tools DTH3007SD Brochure

PATENTED
TECHNOLOGY!
SD12
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
2
General Tools & Instruments
Air Speed Meters
DAF4207SD Anemometer-Thermometer 3-4 HWA4214SD Hot Wire Anemometer-T hermometer 5-6 DLAF930SD Environment Meter 7-8
DSM402SD Class 2 Sound Level Meter 9-10 DSM403SD Class 1 Sound Level Meter 11-12
UV254SD UVA, UVC Light Meter 13-14 DLM112SD Light Meter 15-16
DT4947SD 4-Channel Thermometer 17-18 DT4208SD 12-Channel Temperature Recorder 19-20
PM930SD Pressure Meter 21-22
DTH3007SD Humidity-Temperature Meter 23-24
VM8205SD Vibration Meter 25-26
DPH230SD pH, ORP Meter 27-28 DCT430SD Conductivity , TDS Meter 29-30 DOM551SD Dissolved Oxygen Meter 31-32 WK2017SD pH, ORP, DO, CD, TDS, Salt Meter 33-34
Sound Level Meters
Light Meters
Thermocouple Thermometers
Pressure Meter
Humidity Meter
Vibration Meter
Water Quality Meters
Item No. Description Page No.
•Commercial/industrial ventilation
•Energy audits
•HVAC/R installations
•Paint spray booths
Applications:
Anemometer-Thermometer
with Excel-Formatted Data Logging SD Card
Accurately Measures Air (Wind) Speed and Temperature
Typical Excel Data
Typical Excel Plotted Data
Energy Auditing
Industrial Vent
3
No. DAF4207SD
This instrument’s unique
feature is its patented
technique for storing
sampled data in Excel
format on removable
SD memory cards
Patented Technology
DAF4207SD
• Hard carrying case
• Combination air-
speed temperature probe (General P/N P4207SD)
2 GB SD memory card
• User’s manual
• Includes combination air speed-temperature probe
• Displays air (wind) speed in meters/second, feet per minute, kilometers/hr,
knots
(nautical miles per hour),
or miles per hour
• Displays temperature in °F or °C
• Big (2.5 in. diagonal) front-panel green backlit LCD is easy to read
• Displays maximum and minimum readings and holds any reading
• Automatically logs measurements at sampling time settable from one second to one hour
• Also supports manual data logging and changing of SD card storage location
• Auto power off function
Optional Accessories:
• 9VDC adapter for 110V power supply (General P/N AC1)
• “K” Type thermocouples
General P/N TPK500 (-50° to 500°F) General P/N TPK05 (-40° to 562°F) General P/N TPK03 (-40° to 950°F)
• SDRD1 - SD Card Reader
Included Accessories:
Features:
Specifications:
Embedded Microcontroller: Custom one-chip LSI device
Display Type: LCD with green backlight
Display Size: 2.05 x 1.5 in. (52 x 38mm) Parameters Measured: Air speed, temperature
Measurement Range:
• F
or air speed: 0.4 to 30 m/sec, 1.4 to 126 km/hr,
0.9 to 78.3 mph, 0.8 to 68 knots, 79 to 6890 ft/min
• F
or temperature: 32° to 122°F (0° to 50°C)
Measurement Accuracy:
• F
or air speed: ± (2% + 0.2 m/sec), ± (2% + 0.8 km/hr),
± (2% + 0.4 mph), ± (2% + 0.4 knots), ± (2% + 40 ft/min)
• F
or temperature: ± 1.5°F (± 0.8°C)
Measurement Resolution:
• F
or air speed: 0.1 m/sec, 0.1 km/hr, 0.1 mph, 0.1 knots,
1.0 ft/min
• F
or temperature: 0.1°F or C
Data Logging Sampling Time:
1 second to 1 hour
Settable Parameters: Date, time, auto power off, beep sound, sampling time, decimal point or comma decimal division, temperature unit, air speed unit, optional thermocouple type (K or J)
Storable/Recallable Readings: Maximum, minimum SD Card Capacity: 1GB to 16GB Operating Temperature: 32° to 122°F (0° to 50°C) Operating Relative Humidity: 0 to 85%
Power Consumption
15 mADC (normal operation,
with backlight off
and SD card not sa
ving data)
• 36 mADC with backlight on and card sa
ving data
• 48 mADC with backlight on and card sa
ving data
Dimensions of Instrument:
7.99 x 2.99 x 1.50 in. (203 x 76 x 38mm)
Weight of Instrument: 1.13 lb. (515g) Diameter of Probe Head: 2.83 in. (72mm)
Power Source:
Six “AA” batteries or optional 9-VDC AC adapter
Anemometer-Thermometer
with Excel-Formatted Data Logging SD Card
4
No. DAF4207SD
Visit us at www.TestEquipmentDepot.com
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Hot Wire Anemometer-Thermometer
with Excel-Formatted Data Logging SD Card
Accurately Measures Air (Wind) Speeds As Low As 0.5 mph and Air Temperatures within ±1.5
°F (± 0.8°C)
Typical Excel Data
Typical Excel Plotted Data
Calibrating HVAC S ystems
•Environmental testing
• Maintenance and repair of air conveyors and flow hoods in clean rooms
•Calibrating low-speed fans and blowers
•B
alancing velocity profiles in furnaces
and refrigera
ted cases
•Precision calibration of HVAC/R systems
5
Minimally Invasive Duct Leak Testing
No. HWA4214SD
Applications:
This instrument’s unique
feature is its patented
technique for storing
sampled data in Excel
format on removable
SD memory cards
Patented Technology
HWA4214SD
• Hard carrying case
• T
elescoping air speed/
tempera
ture probe
(General P/N P4214SD)
2 GB SD memory card
• User’s manual
Optional Accessories:
• 9VDC adapter for 110V power supply (General P/N AC1)
• “K” Type thermocouples
General P/N TPK500 (-50
° to 500°F)
General P/N TPK05 (-40
° to 562°F)
General P/N TPK03 (-40
° to 950°F)
• SDRD1 - SD Card Reader
Included Accessories:
• Includes telescoping air speed-temperature probe
• Displays air (wind) speed in meters/second, feet per minute, kilometers/hr, knots (nautical miles per hour), or miles per hour
• Measures air speeds down to 0.2 m/sec with 0.01 m/sec resolution (down to 40 ft/min with 1 ft/min resolution)
• Displays temperature in °F or °C
• Big (2.5 in. diagonal) front-panel green backlit LCD is easy to read
• Displays maximum and minimum readings and holds any reading
• Automatically logs measurements at sampling time settable from one second to one hour
• Also supports manual data logging and changing of SD card storage location
• Auto power off function
Features:
Specifications:
Embedded Microcontroller: Custom one-chip LSI device Display Type: LCD with green backlight Display Size: 2.05 x 1.5 in. (52 x 38mm) Parameters Measured: Air speed, temperature
Measurement Range:
• For air speed: 0.2 to 25 m/sec, 0.7 to 172 km/hr, 0.5 to
44.7 mph,
0.4 to 38.8 knots, 40 to 3940 ft/min
• F
or temperature: 32
° to 122°F (0° to 50°C)
Measurement Accuracy:
• For air speed: ± (5% + 0.1 m/sec), ± (5% + 0.3 km/hr), ± (5% + 0.2 mph), ± (5% + 0.2 knots), ± (5% + 20 ft/min)
• For temperature: ± 1.5
°F (± 0.8°C)
Measurement Resolution:
• For air speed: 0.01 m/sec (0.2 to 5.0 m/sec), 0.1 m/sec (5.1
to 25.0 m/sec); 0.01 km/hr (0.7 to 18 km/hr), 0.1 km/hr (18 to 72 km/hr); 0.01 mph (0.5 to 11.20 mph), 0.1 mph (11.2 to 44.7 mph); 0.01 knot (0.4 to 9.7 knots), 0.1 knot (9.7 to 38.8 knots); 1 ft/min (40 to 3940 ft/min)
• F
or temperature: 0.1
° F or C
Data Logging Sampling Time: 1 second to 1 hour Settable Parameters: Date, time, auto power off, beep sound,
sampling time, decimal point or comma decimal division, temperature unit, air speed unit, optional thermocouple type (K or J)
Storable/Recallable Readings: Maximum, minimum SD Card Capacity: 1 GB to 16 GB Operating Temperature: 32° to 122°F (0° to 50°C) Operating Relative Humidity: 0 to 85%
Power Consumption:
• 30 mADC (normal operation, with backlight off and SD card not sa
ving data)
• 50 mADC (with backlight on and card sa
ving data)
Dimensions of Instrument:
7.99 x 2.99 x 1.50 in. (203 x 76 x 38mm)
Weight of Instrument: 1.13 lb. (515g)
Dimensions of Probe:
0.4724 in. (diameter) x 11.02 in.(collapsed)/37 in.(extended)
(12mm x 280mm/940mm)
Power Source:
Six “AA” batteries or optional 9-VDC AC adapter
Hot Wire Anemometer-Thermometer
with Excel-Formatted Data Logging SD Card
6
No. HWA4214SD
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
•Facilities management
•Environment control
•OSHA compliance
Applications:
Environment Meter
with Excel-Formatted Data Logging SD Card
Typical Excel Data
Typical Excel Plotted Data
Facilities Management
Environment Control
Accurately Measures Air (Wind) Speed + Temperature, Air Temperature + Humidity, Light & Sound Levels, Surface Temperature
7
No. DLAF930SD
This instrument’s unique
feature is its patented
technique for storing
sampled data in Excel
format on removable
SD memory cards
Patented Technology
DLAF930SD
Specifications:
Embedded Microcontroller: Custom one-chip LSI device Display Type: LCD with green backlight Display Size: 2.05 x 1.5 in. (52 x 38mm) Parameters Measured: Air temperature, relative humidity (R.H.),
air speed, light level
Measurement Range:
• For air speed: 0.4 to 25 m/sec, 1.4 to 90 km/hr, 0.9 to
55.9 mph,
0.8 to 48.6 knots, 80 to 4930 ft/min
• F
or temperature: 32
° to 122°F (0 to 50°C); for R.H., 10 to 95%
• F
or light level: 0 to 20,000 lux, 0 to 1860 ft-cd
Measurement Accuracy:
• For air speed: ± (2% + 0.2 m/sec), ± (2% + 0.8 km/hr), ± (2% + 0.4 mph), ± (2% + 0.4 knots), ± (2% + 40 ft/min)
• For temperature: 1.5
°F (± 0.8°C)
• F
or humidity: ± (3% of reading + 1%) for R.H. values
70%;
± 3% of reading for R.H values < 70%
• F
or light level: ± ( 5% of reading ± 8 digits)
Measurement Resolution:
• For air speed: 0.1 m/sec, 0.1 km/hr, 0.1 mph,
0.1 knots, 1.0 ft/min
• F
or temperature: 0.1
°F or °C
• F
or humidity: 0.1% of reading
• F
or light level: 1 lux, 0.1 ft-cd
Data Logging Sampling Time: 1 second to 1 hour
Settable Parameters: Date, time, auto power off, beep sound,
sampling time, decimal point or comma decimal division, temperature unit, air speed unit, light level unit, optional thermocouple type (K or J)
Storable/Recallable Readings: Maximum, minimum SD Card Capacity: 1 GB to 16 GB Operating Temperature: 32° to 122°F (0° to 50°C) Operating Relative Humidity: 0 to 85%
Power Consumption:
• 3.5 mADC (normal operation, with backlight off and SD card not sa
ving data)
• 28 mADC with backlight on and card sa
ving data
• 40 mADC with backlight on and card sa
ving data
Dimensions of Meter: 5.31 x 2.36 x 1.30 in. (135 x 60 x 33mm) Weight of Meter: 1.13 lb. (515g) Dimensions of Probe: 4.13 x 1.81 x 1.14 in. (105 x 46 x 29mm)
Power Source:
Six “AA” batteries or optional 9-VDC AC adapter
Environment Meter
with Excel-Formatted Data Logging SD Card
• Hard carrying case
• Combination temperature/ humidity/air speed/light level probe (General P/N P930SD)
• 2 GB SD memory card
• User’s manual
Optional Accessories:
• 9VDC adapter for 110V power supply (General P/N AC1)
• “K” Type thermocouples
General P/N TPK500 (-50
° to 500°F)
General P/N TPK05 (-40
° to 562°F)
General P/N TPK03 (-40
° to 950°F)
• Sound level probe/plug adap
ter
(General P/N SC941)
SDRD1 - SD Card Reader
Included Accessories:
8
No. DLAF930SD
• Multi-function probe measures air speed and temperature, air temperature and humidity, and light level. Optional accessories measure surface temperature and sound level
• Big (2.5 in. diagonal) front-panel green backlit LCD is easy to read
• Displays maximum and minimum readings and holds any reading
• Automatically logs measurements at sampling time settable from 1 second to 1 hour
• Also supports manual data logging and changing of SD card storage location
• Auto power off function
Features:
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
•Noise pollution control
•OSHA noise regulatory compliance
•Acoustics design
Applications:
Class 2 Sound Level Meter
with Excel-Formatted Data Logging SD Card
Accurately Measures Sound Levels of Machinery or an Environment with 0.1 dB Resolution
Typical Excel Data
Typical Excel Plotted Data
Acoustics Design
Noise Pollution Control
dB
9
No. DSM402SD
This instrument’s unique
feature is its patented
technique for storing
sampled data in Excel
format on removable
SD memory cards
Patented Technology
DSM402SD
Class 2 Sound Level Meter
with Excel-Formatted Data Logging SD Card
• Hard carrying case
• Sound wind shield ball
• 2 GB SD memory card
• User’s manual
Optional Accessories:
• 9VDC adapter for 110V power supply (General P/N AC1)
• SDRD1 - SD Card Reader
Included Accessories:
Specifications:
Embedded Microcontroller: Custom one-chip LSI device Display Type: LCD with green backlight Display Size: 2.05 x 1.5 in. (52 x 38 mm) Parameter Measured: dB Frequency Range: 31.5 Hz to 8 kHz
Measurement Range:
• 30 to 130 dB in auto ranging mode
• User can also select fixed range of 30 to 80 dB, 50 to 100 dB, or 80 to 130 dB
Measurement Weighting:
• By frequency: frequency weighing uses “A” or “C” standard
• By time: time weighting is fast or slow
(200 ms or 500 ms response time)
Measurement Accuracy:
• With “A” frequency weighting: ± 3.5 dB @ 31.5 Hz, 2. 5 dB
@ 63 Hz, 2 dB @ 125 Hz, 1.9 dB @ 250 Hz, 1.9 dB @ 500 Hz, 1.4 dB @ 1 kHz, 2.6 dB @ 2 kHz, 3.6 dB @ 4 kHz,
5.6 dB @ 8 kHz
Measurement Resolution: 0.1 dB
Data Logging Sampling Time: 1 second to 1 hour Settable Parameters: Date, time, auto power off, beep sound,
sampling time, decimal point or comma decimal division, “A” or “C” frequency weighting, fast or slow time weighting
Storable/Recallable Readings: Maximum, minimum SD Card Capacity: 1 GB to 16 GB Operating Temperature: 32° to 122°F (0° to 50°C) Operating Relative Humidity: 0 to 85%
Power Consumption:
• 8 mADC (normal operation, with backlight off and SD card not saving data)
• 30 mADC with backlight on and card saving data
• 44 mADC with backlight on and card saving data
Dimensions of Meter:
9.65 x 2.68 x 1.77 in. (245 x 68 x 45mm)
Weight of Meter: 1.08 lb. (489g)
Power Source:
Six “AA” batteries or optional 9-VDC AC adapter
10
No. DSM402SD
• Measures sound levels of machinery or an environment
• Big (2.5 in. diagonal) front-panel green backlit LCD is easy to read
• Makes measurements in auto ranging mode or within a manually settable range
• Displays maximum and minimum readings and holds any reading
• Performs automatic data logging at sampling time settable from 1 second to 9 hours
• Also supports manual logging and changing of card storage location
• Auto power off function
Features:
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
•Acoustics design
•Sound system setup
•OSHA compliance
Applications:
Class 1 Sound Level Meter
with Excel-Formatted Data Logging SD Card
Accurately Measures Sound Levels of Machinery or an Environment with 0.1 dB Resolution
Typical Excel Data
Typical Excel Plotted Data
Sound System Setup
Acoustics Design
dB
11
No. DSM403SD
This instrument’s unique
feature is its patented
technique for storing
sampled data in Excel
format on removable
SD memory cards
Patented Technology
DSM403SD
Loading...
+ 25 hidden pages