General Tools CT103 User Manual

MULTI-VOLTAGE
LINE TESTER
USER’S MANUAL
CT103
Please read this manual carefully and
thoroughly before using this product.
KEY FEATURES
• Different visual indications of eight common voltages—four AC and four DC
• UL approved
• Double-insulated housing and leads; safe for CAT II 600V use
• Self-storing leads
• Pocket clip on back
SAFETY INSTRUCTIONS
DANGER
Electric
Shock Risk
Warning
To avoid possible electric shock or personal injury, and to avoid damaging the tester or the equipment being tested:
• Do not use the CT103 in any way not detailed in this manual or the tester’s safety features may be compromised.
• Never use the tester to detect the presence of voltages higher than 500V (AC or DC).
DANGER
Electric
Shock Risk
2
• The CT103 cannot detect the presence of voltages below 110V. Use caution whenever detecting AC voltages above 42VAC
RMS
or DC voltages above 60VDC. Both pose a shock hazard.
• Before using the tester, inspect the case. Do not use the CT103 if the case is damaged. Look for cracks or missing plastic. Pay particular attention to the insulation around the connectors.
• Do not operate the tester around explosive gas, vapor, or dust.
• When using the probes, keep your fingers behind the finger guards. Never touch the metal ends of the probes when making a measurement.
OPERATING INSTRUCTIONS
To detect the presence of AC or DC voltage and identify its level, insert the test leads into an electric outlet (see Fig. 1 on the bottom of the next page) or carefully touch the leads to two points of an energized circuit.
3