1. SAFETY RULES
These connectors are designed for use at temperatures between 0°C to 40°C
and altitudes up to 2,000m.
To ensure that the connectors are used safely, follow all safety and operating
instructions in this operation manual.
Do not use the connectors if they appear damaged.
When using the connectors, keep your ngers on the plastic insulating body,
Disconnect any wire, lead, or alligator clips before inserting or extracting the
connector.
Make sure power is off before cutting, desoldering, or breaking the circuit wires.
Small amounts of current can be dangerous.
Do not use on circuits powered with more than 30 VDC.
To avoid electrical shock, use CAUTION when working above 60V DC or 25V
AC rms. Such voltages pose a shock hazard.
To avoid electrical shock or damage to the connectors, do not exceed the input
limits.
2. INTERNATIONAL SYMBOLS
Important information Dangerous Voltages
see manual Continuity AC Ground DC Double Insulation
4. OPERATION
4.1 Connectors Description
1) Connector contacts tabs
2) Insulating plastic body
3) Fuse socket contacts
4.2 Connection to fuse sockets
CAUTION: Remove if possible the power from the socket,
otherwise disconnect all loads from the socket circuits. Always disconnect any test leads or wires attached to the connector tabs before proceeding to insert the connector into the fuse socket.
3. TECHNICAL SPECIFICATIONS
Connection Tabs
3.1 General Specifications
Fuses Compatibility: Mini, ATO (ATC) and Maxi size automotive blade fuses Contacts Material: Nickel plated bronze Connector Contacts Tabs: 1/4 Inch Quick Connects Insulating Body: ABS Dimentions (LxWxD): Mini 1.47 x 0.91 x 0.19 Inches
37.3 x 23.1 x 4.83 mm ATO/ATC 1.58 x 0.94 x 0.19 Inches
40.1 x 23.9 x 4.83 mm Maxi 2.01 x 1.16 x 0.30 Inches
51.1 x 29.5 x 7.62 mm Weight: Mini 0.11 Oz. (3.12 g) ATO/ATC 0.17 Oz. (4.58 g)
5. MAINTENANCE
CAUTION: Do not submerge the connectors on any
Maxi 0.34 Oz. (9.16 g)
3.2 Electrical Specifications
Do not exceed the maximum input voltage and/or current to prevent
injury and damage to the connectors and/or sockets.
CAUTION: These connectors do not provide overcurrent
protection for the circuits, therefore when used to supply current to loads, an external current limiting device should be added to the
5.1 Cleaning
Periodically wipe the connectors with a soft damp cloth and mild household cleanser. Do not use abrasives or solvents. Ensure that no water gets inside the plastic insulating body to prevent possible shorts and damage.
6. WARRANTY
One year limited warranty, For details see Standard Warranty Informa­tion in our webpage or you may request a printed copy..
circuit.
Size Max. Rated Voltage Max. Rated current
Mini 32 VDC 20 ADC
ATO/ATC 32 VDC 30 ADC
Maxi 32 VDC 40 ADC