General Semiconductor UGF10DCT, UGF10CCT, UGF10BCT, UGF10ACT Datasheet

NEW PRODUCT NEW PRODUCT NEW PRODUCT
0.060 (1.52)
0.405 (10.27)
0.383 (9.72)
0.670 (17.2)
0.646 (16.4)
0.191 (4.85)
0.171 (4.35)
0.600 (15.5)
0.580 (14.5)
0.560 (14.22)
0.530 (13.46)
0.037 (0.94)
0.027 (0.69)
0.140 (3.56)
0.130 (3.30)
0.350 (8.89)
0.330 (8.38)
0.188 (4.77)
0.172 (4.36)
0.110 (2.80)
0.100 (2.54)
0.131 (3.39)
0.122 (3.08)
0.110 (2.80)
0.100 (2.54)
0.022 (0.55)
0.014 (0.36)
0.105 (2.67)
0.095 (2.41)
0.205 (5.20)
0.195 (4.95)
PIN 1
PIN 3
PIN 2
1
3
PIN
2
DIA
DIA.
UGF10ACT THRU UGF10DCT
ULTRAFAST SOFT RECOVERY RECTIFIER
Reverse Voltage - 50 to 200 Volts Forward Current - 10.0 Amperes
ITO-220AB
FEATURES
Plastic package has Underwriters Laboratories
Flammability Classification 94V-0
Ideally suited for free wheeling diode power factor
correction applications
250°C/10 seconds at terminals
Glass passivated chip junction
MECHANICAL DATA
Case: JEDEC ITO-220AB molded plastic body Terminals:Plated leads, solderable per MIL-STD-750,
Method 2026
Polarity: As marked Mounting Position: Any Mounting T orque: 5 in.- lbs. max. Weight: 0.08 ounce, 2.24 grams
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
Maximum repetitive peak reverse voltage V Working peak reverse voltage V Maximum RMS voltage V Maximum DC blocking voltage V Maximum average forward rectified current at T
=100°C I
C
Peak forward surge current
8.3ms single half sine-wave superimposed I on rated load (JEDEC Method) per leg
Maximum instantaneous forward voltage per leg at I
Maximum reverse leakage current per leg T at working peak reverse voltage T
Maximum reverse recovery time per leg at I
=1.0A, di/dt=100A/µs, VR=30V, Irr=0.1 I
F
Maximum reverse recovery time per leg at Maximum 25 I
=0.5A, IR=1.0A, Irr=0.25A Typical
F
Maximum reverse recovery current per leg at I
=5A, di/dt=50A/µs,VR=30V
F
Maximum stored charge per leg Maximum 5.5 I
=2A, di/dt=20A/µs, VR=30V Irr=0.1 I
F
Typical ther mal resistance from junction to case per leg R Operating junction and storage temperature range T
RM
RM
=10A, TJ=25°C 1.25
F
I
=5A, TJ=25°C V
F
I
=5A, TJ=150°C 0.895
F
=25°C 10
J
=100°C
J
Typical
, T
J
UGF10ACT UGF10BCT UGF10CCT UGF10DCT
RRM
RWM
RMS
DC
(AV)
FSM
F
I
R
t
rr
t
rr
I
RM
Q
rr
ΘJC
STG
50 100 150 200 Volts 50 100 150 200 Volts 35 70 105 140 Volts
100 100 200 200 Volts
10 Amps
60 Amps
1.10 Volts
200
25 ns
15
0.7 Amps
4.5
6.0 °C/W
-40 to +150 °C
UNITS
µA
ns
nC
NOTICE: Advanced product information is subject to change without notice
4/98
0
25
50
75
100
125
150
0
5
10
15
1
10
100
1
10
100
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0.01
0.1
1
10
100
25
50
75
100
125
0
10
20
30
40
50
0.1
1
10
100
1
10
100
20
40
60
80
100
0.1
1
10
100
1,000
RATINGS AND CHARACTERISTIC CURVES UGF10ACT THRU UGF10DCT
AVERAGE FORWARD CURRENT, AMPERES
FIG. 1 -FORWARD CURRENT DERATING CURVE
RESISTIVE OR INDUCTIVE LOAD
CASE TEMPERATURE, °C
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
TJ=25°C PULSE WIDTH=300µs 1% DUTY CYCLE
TJ=125°C
TJ=100°C
PEAK FORWARD SURGE CURRENT,
AMPERES
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT PER LEG
8.3ms SINGLE HALF SINE-WAVE (JEDEC Method)
=105°C
T
C
NUMBER OF CYCLES AT 60 H
Z
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
PER LEG
TJ=125°C
TJ=100°C
AMPERES
INSTANTANEOUS FORWARD CURRENT,
nC/ns
STORED CHARGE/REVERSE RECOVERY TIME,
TJ=25°C
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG. 5 - REVERSE SWITCHING CHARACTERISTICS
PER LEG
@2A, 20A/µs
@5A, 50A/µs
@1A, 100A/µs
@5A, 50A/µs
@1A, 100A/µs
@2A, 20A/µs
JUNCTION TEMPERATURE, °C
MICROAMPERES
TJ=25°C
INSTANTANEOUS REVERSE LEAKAGE CURRENT,
FIG. 6 - TYPICAL JUNCTION CAPACITANCE PER LEG
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
TJ=125°C f=1.0 MHz Vsig=50MVp-p
CAPACITANCE, pF
t
rr
Q
rr
REVERSE VOLTAGE, V OLTS
Loading...