General Semiconductor SRP600K, SRP600J, SRP600G, SRP600D, SRP600B Datasheet

...
SRP600A THRU SRP600K
0.052 (1.32)
0.048 (1.22)
0.360 (9.1)
0.340 (8.6)
DIA.
1.0 (25.4) MIN.
0.360 (9.1)
0.340 (8.6)
1.0 (25.4) MIN.
FAST SWITCHING PLASTIC RECTIFIER
Reverse Voltage - 50 to 800 Volts Forward Current - 6.0 Amperes
Case Style P600
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS 600A 600B 600D 600G 600J 600K UNITS
Maximum repetitive peak reverse voltage V Maximum RMS voltage V Maximum DC blocking voltage V Maximum average forward rectified current
0.375" (9.5mm) lead length at T
=55°C
A
Peak forward surge current
8.3ms single half sine-wave superimposed on I rated load (JEDEC Method)
Maximum instantaneous forward voltage at 6.0A V Maximum DC reverse current T
at rated DC blocking voltage T Maximum reverse recovery time Typical junction capacitance Typical thermal resistance
(NOTE 1)
(NOTE 2)
(NOTE 3)
=25°C 10.0 µA
A
=100°C
A
Operating junction temperature range T Storage temperature range T
I
R
FEATURES
Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
High surge current capabilityConstruction utilizes void-free molded plastic techniqueFast switching for high efficiencyHigh temperature soldering guaranteed:
250°C/10 seconds, 0.375" (9.5mm) lead length, 5 lbs. (2.3kg) tension
MECHANICAL DATA
Case: Void-free molded package body Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end Mounting Position: Any Weight: 0.07 ounce, 2.1 grams
SRP SRP SRP SRP SRP SRP
RRM RMS
DC
(AV)
FSM
F
I
R
t
rr
C
J
ΘJA
J
G -50 to +150 °C
ST
50 100 200 400 600 800 Volts 35 70 140 280 420 560 Volts 50 100 200 400 600 800 Volts
6.0 Amps
300.0 Amps
1.3 Volts
1.0 mA
100 100 150 150 200 200 ns
300.0 pF
10.0 °C/W
-50 to +125 °C
NOTES:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A (2) Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts (3) Thermal resistance from junction to ambient at 0.375” (9.5mm) lead length, with both leads equally to heat sink
4/98
020406080100
0.01
0.1
1
10
20 40 60 80 100 120 140 160 180
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
75 80 85 90 95 100 105 110 115 120 125
0
4
8
12
16
20
110100
100
150
200
250
300
350
400
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
0
5.0
10
15
20
25
0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
0.1
1
10
100
RATINGS AND CHARACTERISTIC CURVES SRP600A THRU SRP600K
FIG. 1 - FORWARD CURRENT DERATING CURVE
RESISTIVE OR INDUCTIVE LOAD
Ipk/I
AV = π
CAPACITIVE LOADS
5.0 = Ipk/I
AV
10 20
AMPERES
AVERAGE FORWARD CURRENT,
1.1 x 1.1” (30 x 30mm) COPPER PADS
AMBIENT TEMPERATURE, °C
FIG. 3 - MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT
8.3ms SINGLE HALF SINE-WAVE (JEDEC Method)
TJ=25°C
FIG. 2 - FORWARD CURRENT DERATING CURVE
RESISTIVE OR INDUCTIVE LOAD
L=0.12”(3.2mm)
AMPERES
AVERAGE FORWARD CURRENT,
L=0.25”(6.3mm)
L=0.375”(9.5mm)
L=0.62”(15.9mm)
1.6 x 1.6 x 0.04” (40 x 40 x 1mm) COPPER HEAT SINKS
L=LEAD LENGTH
LEAD TEMPERATURE, °C
FIG. 4 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
TJ=25°C PULSE WIDTH=300µs 1% DUTY CYCLE
AMPERES
TJ=125°C
PEAK FORWARD SURGE CURRENT,
FIG. 5 - TYPICAL REVERSE CHARACTERISTICS
MICROAMPERES
NUMBER OF CYCLES AT 60 H
TJ=100°C
TJ=50°C
TJ=25°C
Z
JUNCTION TO LEAD,°C/W
INSTANTANEOUS REVERSE CURRENT,
RΘJL, THERMAL RESISTANCE FROM
PERCENT OF RATED PEAK REVERSE VOLTAGE, %
AMPERES
INSTANTANEOUS FORWARD CURRENT,
INSTANTANEOUS FORWARD VOLTAGE,
FIG. 6 - TYPICAL THERMAL RESISTANCE
L=LEAD LENGTH
COPPER HEATSINKS
EQUAL LEAD LENGTHS TO HEAT SINK, INCHES
VOLTS