General Semiconductor KBU8G, KBU8D, KBU8J, KBU8M, KBU8A Datasheet

...
KBU8A THRU KBU8M
0.160 (4.1)
0.065 (1.7)
0.185 (4.7)
0.895 (22.7)
0.935 (23.7)
0.140 (3.6)
0.165 (4.2)
0.085 (2.2)
0.240 (6.09)
0.200 (5.08)
0.220 (5.6)
0.180 (4.6)
0.075 (1.9) R. TYP. (2 PLACES)
45
o
0.205 (5.2)
0.185 (4.7)
0.052 (1.3)
0.048 (1.2)
0.280 (7.1)
0.260 (6.6)
DIA.
0.760 (19.3)
MAX.
0.700 (17.8)
0.660 (16.8)
1.0
(25.4)
MIN.
0.455 (11.3)
0.405 (10.3)
SINGLE-PHASE BRIDGE RECTIFIER
Reverse Voltage - 50 to 1000 Volts Forward Current - 8.0 Amperes
Case Style KBU
Dimensions in inches and (millimeters)
FEATURES
Plastic material used carries Underwriters Laboratory
Flammability Classification 94V-0
This series is UL listed under Recognized Component Index,
High case dielectric strength
of 1500 V
Ideal for printed circuit boardsHigh forward surge current capabilityHigh temperature soldering guaranteed:
250°C/10 seconds, 0.375" (9.5mm) lead length, 5lbs. (2.3 kg) tension
Case: Molded plastic body Terminals: Plated leads solderable per MIL-STD-750,
Method 2026
Mounting Position: Any Mounting T orque: 5 in.-lb. max. Weight: 0.3 ounce, 8.0 grams
RMS
MECHANICAL DATA
(NOTE 1)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS 8A 8B 8D 8G 8J 8K 8M UNITS
Maximum repetitive peak reverse voltage V Maximum RMS voltage V Maximum DC blocking voltage V Maximum average forward rectified T
output current at T
=100°C
C
=45°C
A
(NOTE 1, 3)
(NOTE 2)
Peak forward surge current single half sine-wave superimposed on rated load (JEDEC Method) T
Maximum instantaneous forward voltage drop per leg at 8.0A
Maximum DC reverse current at rated T DC blocking voltage per leg T
Typical thermal resistance per leg
(NOTE 2) (NOTE 3)
=150°C
J
=25°C 10.0 µA
A
=125°C
A
Operating junction and storage temperature range T
NOTES:
(1) Recommended mounting position is to bolt down on heatsink with silicone thermal compound for maximum heat transfer with #6 screw (2) Units mounted in free air, no heatsink, P.C.B. at 0.375" (9.5mm) lead length with 0.5 x 0.5” (12 x 12mm) copper pads (3) Units mounted on a 3.0 x 3.0” x 0.11" thick (7.5 x 7.5 x 0.3cm) Al. Plate heatsink
R R
J
RRM RMS
I
(AV)
I
FSM
V
, T
DC
I
R
ΘJA ΘJC
KBU KBU KBU KBU KBU KBU KBU
50 100 200 400 600 800 1000 Volts 35 70 140 280 420 560 70 0 Volts 50 100 200 400 600 800 1000 Volts
8.0
6.0
300.0 Amps
F
1.0 Volts
1.0 mA
18.0
3.0
STG
-50 to +150 °C
Amps
°C/W
4/98
0 50 100 150
0
2.0
4.0
6.0
8.0
0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3
0.1
1
10
100
110100
0
50
100
150
200
250
300
1 10 100
10
100
400
0 20 40 60 80 100
0.01
0.1
1
10
50
RATINGS AND CHARACTERISTICS CURVES KBU8A THRU KBU8M
FIG. 1 - DERATING CURVE OUTPUT RECTIFIED
CURRENT
HEAT-SINK MOUNTING,T
3.0 x 3.0 x 12”THK AL. PLATE (7.5 x 0.3cm)
C
AMPERES
P.C.B. MOUNTING, T
AVERAGE FORWARD CURRENT,
0.375” (9.5mm) LEAD LENGTH
0.5 x 0.5” (12 x 12mm) COPPER PADS 60 HZRESISTIVE OR INDUCTIVE LOAD
A
TEMPERATURE, °C
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
TJ=25°C PULSE WIDTH=300µs 1% DUTY CYCLE
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
SINGLE SINE-WAVE (JEDEC Method) TJ=150°C
AMPERES
PEAK FORWARD SURGE CURRENT,
1.0 CYCLE
NUMBER OF CYCLES AT 60 H
Z
FIG. 4 - TYPICAL REVERSE LEAKAGE
CHARACTERISTICS PER LEG
TJ=100°C
AMPERES
INSTANTANEOUS FORWARD CURRENT,
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
PER LEG
TJ=25°C f=1.0 MHz Vsig=50mVp-p
MICROAMPERES
INSTANTANEOUS REVERSE CURRENT,
TJ=25°C
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
JUNCTION CAPACITANCE, pF
REVERSE VOLTAGE, VOLTS