GI820 THRU GI828
0.052 (1.32)
0.048 (1.22)
0.360 (9.1)
0.340 (8.6)
DIA.
1.0 (25.4)
MIN.
0.360 (9.1)
0.340 (8.6)
1.0 (25.4)
MIN.
FAST SWITCHING PLASTIC RECTIFIER
Reverse Voltage - 50 to 800 Volts Forward Current - 5.0 Amperes
Case Style P600
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
FEATURES
♦ Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
♦ High surge current capability
♦ High forward current operation
♦ Fast switching for
high efficiency
♦ Construction utilizes void-free molded plastic technique
♦ Uniform molded body
♦ High temperature soldering guaranteed:
250°C/10 seconds, 0.375" (9.5mm) lead length,
5 lbs. (2.3kg) tension
MECHANICAL DATA
Case: Void-free molded plastic body
Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.07 ounce, 2.1grams
SYMBOLS GI820 GI821 GI822 GI824 GI826 GI828 UNITS
Maximum repetitive peak reverse voltage V
Maximum RMS voltage V
Maximum DC blocking voltage V
Maximum non-repetitive peak reverse voltage V
Maximum average forward rectified current
0.375" (9.5mm) lead length at T
=55°C
A
RRM
RMS
RSM
I
(AV)
DC
50 100 200 400 600 800 Volts
35 70 140 280 420 560 Volts
50 100 200 400 600 800 Volts
75 150 250 450 650 880 Volts
Peak forward surge current
8.3ms single half sine-wave superimposed on I
FSM
rated load (JEDEC Method)
Maximum instantaneous forward voltage
at 5.0A T
at 15.7A T
Maximum reverse current T
at rated DC blocking voltage T
Typical junction capacitance
(NOTE 1)
Maximum reverse recovery time
Maximum reverse recovery current
Typical thermal resistance
Operating junction and storage temperature range T
NOTES:
(1) Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts
(2) Reverse recovery test conditions: I
(3) Thermal resistance from junction to ambient at 0.375” (9.5mm) lead length, with both leads equally to heat sink
(NOTE 3)
=1.0A, VR=30V, di/dt=50A/µs, and Irr=10% IRMfor measurement of t
F
= 25°C 1.10 Volts
J
=150°C
J
= 25°C 10.0 µA
A
=100°C
A
(NOTE 2)
(NOTE 2)
V
F
I
R
C
J
t
rr
I
RM(REC)
R
ΘJA
, T
J
STG
4/98
5.0 Amps
300.0 Amps
1.05
1.0 mA
300.0 pF
200.0 ns
2.0 Amps
10.0 °C/W
-50 to +150 °C
rr
0204060
80
100
0.01
0.1
1
10
20 40 60 80 100 120 140 160 180
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
75 85 95 105 115 125 135 145 155 165 175
0
4.0
8.0
12
16
20
110100
100
150
200
250
300
350
400
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
1.0
0
5.0
10
15
20
25
0.60.81.01.21.41.61.82.0
0.1
1
10
100
RATINGS AND CHARACTERISTIC CURVES GI820 THRU GI828
FIG.1 - FORWARD CURRENT DERATING CURVE
Ipk/I
AV=π
CAPACITIVE LOADS
5.0 I
(pk)
10 I
(AV)
20
AMPERES
AVERAGE FORWARD CURRENT,
1.1 x 1.1” (30 x 30mm)
COPPER PADS
AMBIENT TEMPERATURE, °C
FIG. 3 - MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
TA=25°C
FIG. 2 - FORWARD CURRENT DERATING CURVE
RESISTIVE OR INDUCTIVE LOAD
L= LEAD LENGTH
L=0.12”(3.2mm)
AMPERES
AVERAGE FORWARD CURRENT,
L=0.25”(6.3mm)
L=0.375”(9.5mm)
L=0.62”(15.9mm)
LEAD TEMPERATURE, °C
1.6” x 1.6” x 0.04”
(40mm x 40mm x 1mm)
COPPER HEATSINK
FIG. 4 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
TJ=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
AMPERES
TJ=125°C
PEAK FORWARD SURGE CURRENT,
FIG. 5 - TYPICAL REVERSE CHARACTERISTICS
MICROAMPERES
NUMBER OF CYCLES AT 60 Hz
TJ=100°C
TJ=50°C
TJ=25°C
AMPERES
INSTANTANEOUS FORWARD CURRENT,
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG. 6 - TYPICAL THERMAL RESISTANCE
L= LEAD LENGTH
JUNCTION TO LEAD, °C/W
INSTANTANEOUS REVERSE CURRENT,
PERCENT OF RATED PEAK REVERSE VOLTAGE, %
RΘJL, THERMAL RESISTANCE FROM
EQUAL LEAD LENGTHS TO HEAT SINK, INCHES