General Semiconductor GI1004, GI1003, GI1002, GI1001 Datasheet

Reverse Voltage - 50 to 200 Volts Forward Current - 1.0 Ampere
0.034 (0.86)
0.028 (0.71) DIA.
0.150 (3.8)
0.100 (2.5) DIA.
1.0 (25.4) MIN.
0.240 (6.1)
MAX.
1.0 (25.4) MIN.
PATENTED*
Dimensions in inches and (millimeters)
*
Brazed lead assembly is covered by Patent No.3,930,30
GI1001 THRU GI1004
GLASS PASSIVATED FAST EFFICIENT RECTIFIER
FEATURES
DO-204AP
High temperature metallurgically bonded constructionGlass passivated cavity-free junctionSuperfast recovery time for high efficiencyLow forward voltage, high current capabilityCapable of meeting environmental standards of
MIL-S-19500
Hermetically sealed packageLow leakage currentHigh surge capabilityHigh temperature soldering guaranteed:
350°C/10 seconds, 0.375" (9.5mm) lead length, 5 lbs. (2.3kg) tension
MECHANICAL DATA
Case: JEDEC DO-204AP solid glass body Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end Mounting Position: Any Weight: 0.02 ounce, 0.56 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
Maximum repetitive peak reverse voltage V Maximum RMS voltage V Maximum DC blocking voltage V Maximum average forward rectified current
0.375" (9.5mm) lead length at T Peak forward surge current
8.3ms single half sine-wave superimposed on rated load (JEDEC Method) at T
Maximum instantaneous forward voltage at 1.0A V Maximum DC reverse current T
at rated DC blocking voltage T Maximum reverse recovery time Typical junction capacitance Typical thermal resistance
Operating junction and storage temperature range T
L
(NOTE 2)
(NOTE 3) (NOTE 4)
=75°C
75°C
L=
=25°C 2.0
A
=100°C
A
(NOTE 1)
SYMBOLS GI1001 GI1002 GI1003 GI1004 UNITS
50 100 150 200 Volts 35 70 105 140 Volts 50 100 150 200 Volts
1.0 Amp
30.0 Amps
0.975 Volts
50.0
µA
25.0 ns
45.0 pF
65.0
20.0
°C/W
-65 to +175 °C
R R
J
RRM RMS
I
(AV)
I
FSM
C
, T
DC
F
I
R
t
rr
J
ΘJA ΘJL
STG
NOTES: (1) Reverse recovery test conditions:IF=0.5A, IR=1.0A, Irr=0.25A (2) Measured at 1.0 MH (3) Thermal resistance from junction to ambient at 0.375" (9.5mm) lead length and mounted on P.C.B.with 0.5 x 0.5” (12 x 12mm) (4) Thermal resistance from junction to lead at 0.375" (9.5mm) lead length with both leads attached to heatsinks
and applied reverse voltage of 4.0 Volts
Z
4/98
0.40.60.81.01.21.41.61.8
0.01
0.1
1
10
50
1 10 100
0
5.0
10
15
20
25
30
0.1 1 10 100
0
15
30
45
60
75
90
105
0 25 50 75 100 125 150 175
0
0.5
1.0
1.5
0 20 40 60 80 100
0.01
0.1
1
10
100
1,000
RATINGS AND CHARACTERISTIC CURVES GI1001 THRU GI1004
FIG. 1 - MAXIMUM FORWARD CURRENT
RESISTIVE OR INDUCTIVE LOAD
CURRENT, AMPERES
AVERAGE FORWARD RECTIFIED
FIG. 3 - TYPICAL INSTANTANEOUS
DERATING CURVE
0.8 x 0.8 x.04" THICK COPPER HEATSINK (20 x 20 x 1.0mm)
LEAD TEMPERATURE, °C
FORWARD CHARACTERISTICS
T
0.375" (9.5mm)
TJ=25°C
PULSE WIDTH=300µs 1% DUTY CYCLE
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
8.3ms SINGLE HALF SINE-WAVE (JEDEC Method) at TL=75°C
L
AMPERES
PEAK FORWARD SURGE CURRENT,
NUMBER OF CYCLES AT 60 H
FIG. 4 - TYPICAL REVERSE LEAKAGE
CHARACTERISTICS
Z
TJ=125°C
AMPERES
INSTANTANEOUS FORWARD CURRENT,
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE, pF
TJ=25°C f=1.0 MH
Z
Vsig=50mVp-p
MICROAMPERES
TJ=100°C
INSTANTANEOUS REVERSE LEAKAGE CURRENT,
TJ=25°C
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
REVERSE VOLTA GE, VOLTS
Loading...