General Pump KE Owner Manual

K
K
E
E
Owner’s Manual
• Installation
• Use
• Maintenance
General Pump is a
member of the
Interpump Group
GENERAL PUMP
INDEX
1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3
2. SYMBOL DESCRIPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3
3. SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3
3.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3
3.2 High pressure system safety requirements . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3
3.3 Safety of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 4
3.4 General procedures for high pressure lance/gun operation . . . . . . . . . . . . . . .Page 4
3.5 Safety of maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 4
4. PUMP IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 5
5. TECHNICAL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 5
6. DIMENSIONS AND WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 5
7. GENERAL INFORMATION ABOUT SPECIFIC PUMP USE . . . . . . . . . . . . . . . . .Page 6
7.1 Water temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 6
7.2 Maximum flow and pressure ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 6
7.3 Lowest operating RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 6
A member of the Interpump Group
KE SERIES
8. CONNECTION AND PLUGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 6
9. PUMP INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7
9.1 Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7
9.2 Direction of rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7
9.3 Water connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7
9.4 Suction line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7
9.5 Filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 8
9.6 Delivery time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 8
9.7 Hose Diameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 9
10. START UP AND RUNNING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 10
10.1 Before start up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 10
10.2 Starting up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 10
11. MAINTENANCE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 11
11.1 Crank mechanism maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 11
11.2 Fluid end maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 15
12. SCREW CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 17
13. MAINTENANCE TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 17
14. PUMP STOPPED FOR LONG TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 17
15. PRECAUTIONS AGAINST FREEZING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 17
16. EXPLODED VIEWS AND PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 18
17. TROUBLE SHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 20
18. MAINTENANCE TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 21
19. MAINTENANCE LOG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 22
Page 2
GENERAL PUMP
A member of the Interpump Group
KE SERIES
1. INTRODUCTION
Please read this manual carefully before using your pump. It contains the necessary information for correct installation, use and maintenance as well as some practical suggestions for trouble shooting. Providing KE high pressure water plunger pumps are correctly installed and maintained, they will give trouble-free operation for a long time. The manufacturer declines all responsibility for damages arising from the misuse and non-observance of the instructions indicated in this manual.
On receiving the plump, please check that it is complete and in good state. Should you find anything out of order please contact your place of purchase before installing and starting the pump.
2. SYMBOL DESCRIPTIONS
Warning
Potential Danger
Read carefully and understand the manual before operating the pump
Danger
High Voltage
Danger
Wear protective mask
Danger
Wear goggles
3. SAFETY
3.1 General safety instructions
The misuse of a high pressure water unit and the non-observance of the pump installation and maintenance instructions may cause serious damages and/or injuries to people or properties or both.
Any Manufacturer/Operator requested to assemble/use a high pressure water unit should be competent to do so, should have the necessary knowledge on every high pressure component installed in the unit and on the precautions to be taken in order to guarantee the largest safety margins during operation. No precaution, so far as is reasonably practical, should be left out in the interest of safety, both from the Manufacturer and the Operator.
3.2 High pressure unit safety requirements
1. A safety valve should be installed in any delivery line and should be sized to discharge or by-pass the entire pump flow rate
2. High pressure unit components, with particular regard for those units working outside, should be adequately protected against rain, frost and heat.
3. Electric components and wiring should be provided with an adequate degree of protection, able to protect them against spray coming from any direction. They should also be suitable for working in a wet environment.
4. High pressure hoses and any other accessory under pressure should be sized in accordance with the maximum unit working pressure and must always work within the safety margins indicated by the nose/ accessory Manufacturer.
5. High pressure hose ends should be fastened to a steady object in order to prevent them from dangerous sweeping around, should they burst or come off their end fittings.
6. Proper safety guards should be provided to adequately cover transmission joints, pulleys, belts or auxiliary drives.
Danger
Wear protective gloves
Danger
Wear protective boots
Page 3
GENERAL PUMP
3.3 Safety of operation
The access into the area when a high pressure unit is working should be strictly prohibited to unauthorized personnel. The area should be suitably enclosed and its perimeter, so far as is reasonably practical, cordoned off and proper warning notices displayed in prominent positions.
Personnel authorized to enter that area should have been previously trained to do so and informed of the risks arising from failures, misuse and any foreseeable circumstance which may occur during operation. Before starting the pump unit and bringing it up to pressure the Operator is requested to carry out the following checks:
1. Make sure that a correct water supply to the pump is provided.
2. Make sure that water inlet filters are properly clean.
3. Electrical components and wiring, with special emphasis on connections, junction boxes, switches and supply cables should be free from external damage (i.e. exposed and broken wires) and adequately protected against water.
4. High pressure hose should not show apparent external wear and the fittings at both ends should be free from signs of erosion or corrosion.
5. Make sure that all fluids (lubricating oil for pump and engine, cooling water, hydraulic fluids) are at proper levels and in good condition.
6. Make sure the safety guards are in good condition.
The work should stop immediately and the pressure must be released in the event that leakage becomes apparent or if any person becomes aware of an change in condition or any hazard existing or being introduced. Any failure must be promptly reported and then checked personnel.
3.4 General procedures for high pressure gun/lance
operation
1. The Operator should take reasonable care for the
safety of himself and of other persons who may be affected by his acts or omission at work. His actions should always be governed by his good sense and responsibility.
2. The Operator should wear suitable waterproof
protective clothing, having regard to the type of work being undertaken. The clothing set should include adequate hand protection, suitable boots able to ensure proper grip on wet floors, helmet provided with full face shield, waterproof garment providing full cover to the Operator, including his arms. As most water jets produce noise levels in excess of
A member of the Interpump Group
KE SERIES
90 dB(A) suitable ear protection is advised.
NOTE: It must be emphasized that whereas protective clothing provides adequate protection against spray and flying particles, it does not constitute complete protection protection against the direct impact of the water jet. Additional protections in the form of suitable metal shields or barriers may be necessary for certain jetting operation.
3. In most jetting operations it is an accepted practice to employ a team of Operators consisting of two members at least, in order to provide mutual assistance in case of need and to rotate their duties in case of long and heavy work. While the first Operator holds the gun, the second Operator attends the pump unit, keeping close watch on the first Operator for signs of difficulty or fatigue, and watching the surrounding area for intrusion by other persons or unsafe situations. If required, he will shut off the pressure unit until it is safe to continue.
4. The area in which the work is to proceed should be clear of loose items and debris to prevent tripping and slipping hazards.
5. The water jet should be directed only and always against the workpiece even during preliminary operating tests prior to starting work.
6. Where applicable, proper side shields should be suitable placed to safeguard personnel and equipment against contact with grit or particles removed by the water jet.
7. On no account must the Operator be distracted during operation until the jet has been stopped. Personnel having reason to enter the water jetting area should wait until the jet is stopped and his presence known.
8. Each team member must always be aware of the actions and intentions of other team members in order to prevent any dangerous misunderstanding occurring during jetting operation.
9. The pump unit should not be started and brought up to pressure unless each team member is in his designated position, the nozzle directed to the workpiece and the lance or gun securely held.
3.5 Safety of maintenance
Apart from the working pressure regulation no attempt should be made to adjust any nut, hose, fitting, etc., while that part of the system is under pressure. The pump should be stopped and any pressure in the line released prior to making any adjustments.
1. The high pressure water unit should be maintained in accordance with the Manufacturer’s instructions.
2. The unit should be maintained only by competent personnel
3. Service and maintenance should be carried out with proper tools in order to prevent any damage on high pressure connections and fittings.
4. Use of other than original spare parts is strictly forbidden.
Page 4
GENERAL PUMP
A member of the Interpump Group
4. PUMP IDENTIFICATION
Each pump is fitted with a rating plate (see Fig. 1) containing the following information:
2. serial number
3. pump model and version
4. max RPM
5. power absorbed
6. max operating pressure (bar)
6. max flow rate (l/min)
Pump model, pump version and serial number should be specified when ordering spare parts. Should the pump be modified (i.e by changing the original version) than any change should be mentioned on the rating plate for future reference.
5. TECHNICAL FEATURES
FLOW RATE PRESSURE POWER
MODEL RPM
GPM l/min PSI Bar Hp kW
KE SERIES
KE20A 1450 8.3 31.4 4350 300 24.5 18
KE22A 1450 10.0 38 3625 250 24.7 18.16
KE24A 1450 11.9 45.2 3045 210 24.7 18.16
KE28A 1450 16.3 61.6 2175 150 24.0 17.6
KE30A 1450 18.5 70.7 1885 130 23.9 17.6
6. DIMENSIONS AND WEIGHT
Page 5
GENERAL PUMP
A member of the Interpump Group
KE SERIES
7. GENERAL INFORMATION ABOUT PUMP USE
The KE pump has been designed to pump fresh and filtered (360 micron max.) water at room temperature. Special versiona are available for pumping water up to
185oF and for reverse osmosis units.
7.1 Water temperature
The water temperature is critical for the pump life: the higher the water temperature, the more likely it is to create cavitation, resulting in premature seal and valve failures.
For such conditions, use HT series pumps.
7.2 Max flow and pressure ratings
The performance data indicated in the catalog and on the rating plate refer to the maximum performance of the pump. The use of the pump below the rated performances does not allow the drop in power absorbed to be balanced by altering the pressure or volume of the pump above its maximum value.
8. CONNECTIONS AND PLUGS
KE pumps are provided with (Fig. 3): 1 - 2 inlet ports IN Ø 1” NPT
Suction line connection to either inlet port is acceptable, the port not being used should be
sealed with the correct plug. 2 - 2 outlet ports OUT Ø 1/2” NPT 3 - 3 outlet ports OUT Ø 1/4” NPT (designed for
pressure gauge and safety valve only)
7.3 Lowest operating RPM
The lowest operating speed of the crankshaft for all KE pumps (all versions) is 500 RPM.
Page 6
GENERAL PUMP
A member of the Interpump Group
KE SERIES
9. PUMP INSTALLATION
9.1 Positioning
The pump must be installed on a rigid and perfectly flat and horizontal base by means of the proper four M12 threaded feet. The base should be rigid enough to avoid any misalignment or flexing on the pump/transmission coupling axis due to the torque involved during operation. The unit should not be rigidly fixed on the floor but be installed upon vibration dampeners.
The oil plug must absolutely be replaced by the oil stick and the oil level checked. Make sure that you can
easily reach the oil stick even after the unit has been assembled.
Never use rigid coupling on the shaft. The following transmission types are suggested:
- Hydraulic by means of a flange.
- Pulleys.
- Cardan joint (within the max working angles indicated by the manufacturer).
9.2 Direction of rotation
An arrow situated on the crankcase near the shaft indicates the correct direction of rotation. Fig. 4 shows the direction of rotation looking at the pump from the fluid end side.
9.3 Water connections
In order to isolate the high pressure equipment from the pump vibrations it is suggested, where applicable, to use flexible hoses for both suction and delivery lines at least for the first length. The flexible hose must be rigid enough to prevent it from collapsing during the suction stroke, when a partial vacuum may occur.
9.4 Suction line
The pump life is considerably influenced by the effectiveness of the suction line which must have the following characteristics:
1. Internal diameter should be at least 1/2”, in any point, possibly larger depending on the drop in pressure due to the length and shape of the line.
2. Should be as straight as possible minimizing changes in size and direction and positioned in such a way to allow air pockets and bubbles to escape.
3. Should be perfectly airtight.
4. Should be completely free from 90oelbows, diameter reductions, counter slopes, “T” connections and should not be connected to other pipelines.
5. Should positioned in such a way to prevent the pipe emptying after the pump stops.
6. Do not use high pressure hydraulic fittings like 90 elbows, high pressure adapters, high pressure 3 or 4 way nipples and so on.
7. Do not install any kind of detergent injector along the suction line.
8. Do not install standing valves, check valves or other kind of one-way valves.
9. Make sure that the feed tank capacity and the water minimum level do not give rise to turbulence at the tank outlet port, which, in turn, might create cavitation at the pump.
10. Do not connect the by-pass line from the valve directly to the pump suction line.
11. Connect the by-pass line from the valve directly to the feed tank and make sure that both the by-pass and tank feeding flows could not give rise to turbulence at the tank outlet port, which, in turn, might create cavitation at the pump. Proper baffle plates should be provided inside the tank.
12. Before connecting the suction line to the pump inlet port make sure the pipe is perfectly clean inside.
o
Page 7
Loading...