GENERAL PUMPA member of the Interpump Group
CRANKSHAFT “FLIP” INSTRUCTIONS
CRANKSHAFT FLIP PROCEDURES
1) Drain crankcase oil.
HTF, TSF & TSP Series 66
Triplex Plunger Pump
TRIPLEX TRIPLEX
Fig. 1
Fig. 2
Fig. 3
Fig. 4
2) Remove qty. 4 rear cover screws with 5 mm hex wrench.
Fig. 1
3) Remove connecting rod cap bolts with 6 mm hex wrench,
respecting position and orientation of each cap. Position
connecting rod/plunger guides fully into crankcase to
allow clearance of crankshaft removal. Fig. 2 and 3.
4) Remove qty. 4 each bolts retaining side covers with
6 mm hex wrench. Fig. 4 and 5.
Ref 300887 Rev. A
General Pump
is a member of
the Interpump Group
05-12
HTF, TSF, TSP Series 66
Crankshaft Flip Instructions
5) Carefully remove side covers respecting
crankshaft oil seal. Fig. 6 and 7.
Fig. 5
6) Remove crankshaft out crankcase side cover hole
and reassemble shaft position to opposite side.
Fig. 8.
Fig. 6
GENERAL PUMPA member of the Interpump Group
Fig. 7
Fig. 8
Fig. 9
7) Reassemble side cover into crankcase starting
with closed cover respecting O-ring seals and
crankshaft seal. Fig. 9 and 10.
Torque bolts to specifications. Fig. 11.
Ref 300887 Rev. A