General Lock C5000 User Manual

www.GeneralLock.com
C5000 Series Door Closer Installation
Standard and Top-Jamb Installation
STANDARD INSTALLATION:
Regular arm application provides the best power efficiency. It is the only installation that installs on the hinge (pull) side of the door. Regular arm applications require at least 1-3/4” from top of door to ceiling so arm does not hit the ceiling and at least 2-1/2” behind door when door is opened to 90º, so closer body will not damage the wall.
1-3/4”
C
L
TOP-JAMB INSTALLATION:
A
Jamb
9-1/16”
Hinge
2-1/8”
3/4”
C
L
3/8” (max) Head projection
3-7/16”
Opening Dim. A To 120º 6-1/2” 120º - 180º 4”
1”
Top-jamb application is the best alternative to regular arm for power efficiency. It is installed on the frame stop (push) side of the door. It is frequently used on doors with a narrow top rail, such as exterior aluminum storefront doors. Top-jamb applications require the frame to be at least 1-3/4” in height, or else a drop plate must be used (a drop plate provides a mounting surface for the door closer).
C
C
L
9-1/16”
3/4”
3-13/16”
L
A
D:16 — Product Guide 103.1 —
1-3/4”
3-7/16”
1”
Opening Dim. A To 120º 6-1/2” 120º - 180º 4”
1-3/4”
Hinge
www.GeneralLock.com
C5000 Series Door Closer Installation
Parallel Arm Installation and Specifications
PARALLEL ARM INSTALLATION:
Parallel arm application is the least power efficient. It provides approximately 25% less power than regular arm. It is installed on the frame stop (push) side of the door. Since it is parallel with the door, it is chosen for appearances and is least susceptible to vandalism, making it a popular choice in schools. Parallel arm applications require at least 4-1/2” from the top of the door to the bottom mounting point of the door closer, or else a drop plate must be used.
C
L
A
9-1/16”
B
SPECIFICATIONS:
Jamb
2-1/8”
3/4”
5-3/8”
Opening Dim. A Dim. B To 120º 10-3/4” 6-15/16” 120º - 180º 8-3/4” 4-3/4”
C
L
Hinge
Closer for interior and exterior door shall be rack-and-pinion type with a cast aluminum body. Closer shall be non-handed to permit installation on either side of the door. Closer shall be supplied with a standard shoe and soffit plate to allow standard, top-jamb, or parallel installation. Closer shall contains hydraulic fluid that is non-gumming and non-freezing. Door closer shall have two separate, adjustable regulating valves to control sweeping and latching speeds. Closer shall come standard with backcheck feature. Closer shall fit into hole patterns 9-1/16” in width (two holes on each end) and shall be supplied with machine screw and sex nuts and bolts. Closer is ANSI 156.4 Grade 1 and UL Listed for use on labeled fire doors.
— Product Guide 103.1 — D:17
Loading...
+ 1 hidden pages