General Electric WE25X0217 Installation

500A420P003
Pub.# 31-16139
Installation Instructions
Gas Dryer
or Visit our Web site at:
www. GEAppliances.com
BEFORE YOU BEGIN
TOOLS YOU WILL NEED MATERIALS YOU WILL NEED
FOR YOUR SAFETY:
WARNING
• Use only rigid metal or flexible metal 4-in. diameter ductwork for exhausting to the outdoors. Never use plastic or other combustible easy-to-puncture ductwork.
• This appliance must be properly grounded and installed as described in these instructions.
• Do not install or store appliance in an area where it will be exposed to water and/or weather.
• The National Fuel Gas Code restricts installations of gas appliances in garages. They must be 18 in. off the ground and protected by a barrier from vehicles.
• Install the dryer where the temperature is above 50ºF for satisfactory operation of the dryer control system.
Read these instructions completely and carefully.
IMPORTANT - Save these
instructions for local inspector's use.
IMPORTANT - Observe all
governing codes and ordinances.
• Note to Installer - Be sure to leave these instructions with the customer
.
• Note to Customer - Keep these instructions with your Use and Care Book for future reference.
• This dryer must be exhausted to the outdoors.
• Before the old dryer is removed from service or discarded, remove the dryer door
.
• Service Information and the wiring diagram are located in the control console.
• D
• Service of this dryer must be performed by a qualified installer,service agency, or the gas supplier.
o not allow children on or in the appliance. Close
supervision of children is necessary when the appliance is
used near children.
FLAT BLADE SCREWDRIVER
SLIP JOINT PLIERS
LEVEL
10" ADJUSTABLE WRENCHES (2)
8" PIPE WRENCH
SOAP SOLUTION
FOR LEAK DETECTION
DUCT TAPE
GLOVES
SAFETY GLASSES
DUCT CLAMPS (2)
4" DIA. METAL ELBOW
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL DUCT
(IF NEEDED)
EXHAUST HOOD
PIPE COMPOUND
FLEXIBLE GAS LINE CONNECTOR
Step 1 Verify Your Gas Installation (see section 2). Step 2 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 3 Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications.(see section 6) Step 4 Remove the Foam Shipping Pads (see section 1). Step 5 Move the Dryer to the Desired Location. Step 6 Level Your Dryer (see section 8). Step 7 Connect the Gas Supply (see section 3) and check
for leaks (see section 4).
Step 8 Connect the External Exhaust (see section 7). Step 9 Connect the Power Supply (see section 5). Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be Noticed By the Owner.
For Alcove or Closet Installation see section 9. For Bathroom or Bedroom Installation see section 10. For Mobile or Manufactured Home see section 11.
In the state of Massachusetts Installation must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the state.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
03
Installation Instructions
1 PREPARING FOR INSTALLATION OF NEW DRYER
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for proper operation and service.
2 GAS REQUIREMENTS
EXTERNAL DUCT OPENING
GAS INLET PIPE
CSA (AGA) APPROVED NEW FLEXIBLE GAS LINE CONNECTOR
DUCT TAPE
DUCT TAPE
4" METAL DUCT
TIP: Install your dryer before installing your washer. This will allow better access when installing dryer exhaust.
DISCONNECTING GAS
TURN GAS SHUT-OFF VALVE TO THE OFF POSITION.
DISCONNECT AND DISCARD OLD FLEXIBLE GAS CONNECTOR AND OLD DUCTING MATERIAL.
The use of old flexible connectors can cause leaks and personal injury. Always use new flexible connectors when installing gas appliances.
WARNING
INTERNAL DUCT OPENING
WARNING - NEVER REUSE OLD FLEXIBLE CONNECTORS.
REMOVING LINT FROM WALL EXHAUST OPENING
CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FREELY.
WALL
2
TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING THEM AWAY FROM THE DRYER LEGS. BE SURE TO REMOVE ALL OF THE FOAM PIECES AROUND THE LEGS.
Installation must conform to local codes and ordinances, or in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.
• This gas dryer is equipped with a Valve & Burner Assem­bly for use only with natural gas. Using conversion kit WE25X0217, your local service organization can convert this dryer for use with propane (LP) gas. ALL CONVER­SIONS MUST BE MADE BY PROPERLY TRAINED AND QUALIFIED PERSONNEL AND IN A C­CORDANCE WITH LOCAL CODES AND ORDI­NANCE REQUIREMENTS.
• The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of 0.5 PSI (3.4 KPa).
• The dryer must be isolated from the gas supply piping system by closing the equipment shut-off valve during any pressure testing of the gas supply piping of test pressure equal to or less than 0.5 PSI (3.4KPa).
WARNING
DRYER GAS SUPPLY CONNECTION
2"
2-5/8"
3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension the distance between cabinet bottom to floor.
GAS SUPPLY
• A 1/8-in. National Pipe Taper thread plugged tapping, ac­cessible for test gauge connection, must be installed imme­diately upstream of the gas supply connection to the dryer. Contact your local gas utility should you have questions on the installation of the plugged tapping.
• Supply line is to be 1
You must use with this dryer a flexible metal connector listed
/2-in. rigid pipe and equipped with an
accessible shut-off within 6 ft. of, and in the same room
with, the dryer.
• Use pipe thread sealer compound or Teflon tape
appropriate for natural or LP gas.
connector ANSI Z21.24 / CSA 6.10. The length of the connect shall not exceed 3 ft.
Connect flexible metal connector to dryer and gas supply.
• Open shut-off valve.