General Electric UVW8301SLSS Use & Care

SAFETY INFORMATION .............3
USING THE HOOD
Controls ..................................5
Chef Connect .............................5
CARE AND CLEANING
Filters ................................... 6
Surfaces ..................................7
Lights ....................................7
INSTALLATION INSTRUCTIONS ....8
TROUBLESHOOTING TIPS ..........18
WARRANTY ......................... 22
ACCESSORIES ...................... 23
CONSUMER SUPPORT ............. 24
OWNER’S MANUAL &
INSTALLATION INSTRUCTIONS
UVW8301 UVW8361
Write the model and serial numbers here:
WALL HOODS
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Model # _________________
Serial # _________________
You can find them on a label on the inside of the hood.
Para consultar una version en
español de este manual de
internet GEAppliances.com.
49-80816-1 03-18 GEA
ESPAÑOL
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
card included in the packing material.
2 49-80816-1
IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING
SAFETY INFORMATION
WARNING
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Do not use this unit with any solid-state speed
control device.
D. This unit must be grounded.
CAUTION
ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION
TO PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE. DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.
TO REDUCE THE RISK OF FIRE,
FOR GENERAL VENTILATING USE
TO REDUCE RISK OF FIRE AND
WARNING
TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
A. SMOTHER FLAMES with a close-fitting lid, cookie
sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN—You may be
burned.
C. DO NOT USE WATER, including wet dishcloths or
towels—a violent steam explosion will result.
D. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety” published by NFPA.
TO REDUCE THE RISK OF INJURY
READ AND SAVE THESE INSTRUCTIONS
49-80816-1 3
IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING
WARNING
RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on medium settings.
B. Always turn hood ON when cooking at high heat or
when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
C. Clean ventilating fans frequently. Grease should not
be allowed to accumulate on fan or filter.
SAFETY INFORMATION
D. Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
TO REDUCE THE RISK OF A
TO REDUCE THE RISK OF FIRE,
C. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. When applicable, install any makeup (replacement)
air system in accordance with local building
code requirements. Visit GEAppliances.com for
available makeup air solutions. F. Turn off breaker to adjacent rooms while working.
WARNING
USE ONLY METAL DUCTWORK.
Ŷ'RQRWDWWHPSWWRUHSDLURUUHSODFHDQ\SDUWRI\RXU
hood unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.
TO REDUCE THE RISK OF FIRE,
How to Remove Protective Shipping Film and Packaging Tape
Carefully grasp a corner of the protective shipping film with your fingers and slowly peel it from the appliance surface. Do not use any sharp items to remove the film. Remove all of the film before using the appliance for the first time.
To assure no damage is done to the finish of the product, the safest way to remove the adhesive from packaging tape on new appliances is an application of a household liquid dishwashing detergent. Apply with a soft cloth and allow to soak.
NOTE: The adhesive must be removed from all parts. NOTE: For further cleaning instructions/suggestions,
please refer to the Care And Cleaning section.
READ AND SAVE THESE INSTRUCTIONS
4 49-80816-1
Controls
1
USING THE HOOD: Controls / Chef Connect
3
245
4
78
5
2
36
Remote Control
1. Rangehood Control Panel: The control panel
is located on the front of the canopy. The position and function of each control button are noted below.
5. Chef Connect: This is a Bluetooth
2. Fan On/Off: On/Off switch for the fan. The fan
can be operated by pressing any of the fan setting buttons. Hold for 3 seconds to activate Delay Off feature, which automatically turns the fan off after 15 minutes.
3. Fan Settings: Speed control for fan. Press the
button Low for LOW speed, Med for MEDIUM speed, and High for HIGH speed. On Remote, press Up to increase fan speed, press Down to decrease fan speed, including Boost.
4. Light: On/Dim/Off switch for the LED lights. Press
the Light button to turn the lights on, again to set the lights to dim setting, and again to turn the lights off.
6. IR Sensor: Remote control receiver when used
7. Wi-Fi (Remote only): Not available.
8. Delay Off (Remote only): Press and hold
Chef Connect
Chef Connect Operation Bluetooth® Connection
To pair with another device:
To start the pairing process on the hood, press and hold the Chef Connect button for 3 seconds. The backlight for all the icons will light up until the hood is paired with the range or other device. If the pairing is successful, the backlights of all five buttons will flash simultaneously three times and then turn off and the backlight for the Chef Connect button will turn on.
It will time out after 2 minutes if the pairing is not completed, after which the pairing sequence will need to be restarted.
To cancel pairing:
To cancel the pairing, hold the Chef Connect button down for 3 seconds and then turn off the hood.
Default Sync Settings:
The factory default setting for the light will be the brightest. The factory default setting for the fan sync will be OFF. The user can change the Default Sync Settings by
pressing and holding the Low button for 3 seconds. This will enter the Default Settings Mode. Once in this mode, the backlights for all buttons will blink on/off indefinitely and the fan and light will switch to the current Default Sync Setting, so the user knows what the current default value is. At this time, set the light and fan to the desired default levels. Once the user is satisfied with the selection, press and hold the Off button for 3 seconds. This will exit this mode. At that time the backlights will stop blinking and the state of the fan and light will change back to their prior state before entering the Default Settings Mode.
®
pairing feature for use with other compatible Chef Connect enabled products on a cooktop or range. When the device is paired, the light and fan will turn ON at the Default Sync Settings upon receiving a command from the range or cooktop. It will remain ON at that setting until the user changes it. To pair devices, hold down the Chef Connect button for 3 seconds. To turn it back off, hold the button down for another 3 seconds. See the Chef Connect section for more details.
with remote control kit (UXRC1).
Delay Off to toggle Delay Off function.
49-80816-1 5
Filters
Be sure the circuit breaker is off and all surfaces are cool before cleaning or servicing any part of the vent hood.
Metal Grease Filter
The metal filters trap grease during cooking. The filters must ALWAYS be in place when the hood is in
use. The grease filters are dishwasher-safe and should be cleaned every month, depending on usage of the hood.
To remove:
Disengage the filter lock to release the filter.
To replace:
Fit the tabs at the bottom of the filter into the slots in the back of the filter opening. Lift up the front side of the filter and push gently until the filter locks into place. Make sure the filter lock is in the closed position to secure the filter.
To clean:
Swish the filter in hot soapy water and rinse in clean water or wash it in the dishwasher. Do not use abrasive cleansers.
CARE AND CLEANING: Filters
NOTE: Some discoloration of the filter may occur in the
dishwasher.
Charcoal Filter (for recirculation installation only)
If the model is not vented to the outside, the air needs to be recirculated through a disposable charcoal filter that helps remove smoke and odors.
NOTE: DO NOT rinse, or put charcoal filter in an automatic dishwasher.
The charcoal filter is included with the unit. It cannot be cleaned; it must be replaced. It is recommended that the charcoal filter be replaced every 6 months or if it is noticeably dirty or discolored.
Order Charcoal Filter UXCF91
To inquire about purchasing replacement charcoal filters or to find the location of a dealer nearest you, please call our toll-free number:
National Parts Center 800.626.2002 To install:
1. Remove the metal filters—see Metal Grease Filter section.
2. Install the charcoal filter mounts to either side of the motor using three screws per side.
3. Insert the tab on the charcoal filter into the triangular slot on the mount.
4. Clip the charcoal filter in until it is locked
5. Repeat with second filter on the other side of the motor.
6. Replace the metal filters - See Metal Grease Filter section.
To remove:
1. Remove the metal filters—see Metal grease filter section.
2. Unclip the charcoal filter by pressing the release clip.
3. Carefully remove charcoal filter from tab.
Charcoal Filter Mount
6 49-80816-1
Surfaces
Stainless Steel Surfaces
Do not use a steel wool pad; it will scratch the surface.
To clean the stainless steel surface, use warm sudsy water or a stainless steel cleaner or polish. Always wipe the surface in the direction of the brush line. Follow the cleaner instructions for cleaning the stainless steel surface. Cleaners with oxalic acid such as Bar Keepers Friend Soft Cleanser™ will remove surface rust, tarnish, and small blemishes. To receive a coupon for a trial sample of Bar Keepers Friend Soft Cleanser™ follow the link below or scan the QR Code.
www.barkeepersfriend.com/ge
Lights
CARE AND CLEANING: Surfaces / Lights
Use only a liquid cleanser free of grit and rub in the direction of the brush lines with a damp soft sponge.
To inquire about purchasing stainless steel appliance cleaner or polish, or to find the location of a dealer nearest you, please call our toll-free number:
National Parts Center
800.626.2002 GEApplianceParts.com
CAUTION
1. Before attempting to replace the lights, make sure that the light switch is turned off.
2. Rotate light counterclockwise to unlock and pull out. Wearing latex gloves may offer a better grip.
3. Replace with new light of same type, making sure pins are inserted properly into the sockets of the lamp holder and turn clockwise to lock.
All lamps need to be GU10 compatible.
Allow lights to cool before touching.
Lamp Holder
Rotate the lamp until the pins are located in narrow neck of the socket to lock.
49-80816-1 7
Installation
Wall Hoods
UVW8301, UVW8361
Instructions
“If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737)
or visit our website at: GEAppliances.com”
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Ŷ
IMPORTANT — Save these
instructions for local inspector’s use.
Ŷ
IMPORTANT — Observe all governing
codes and ordinances.
Ŷ
Note to Installer – Be sure to leave these
instructions with the Consumer.
Ŷ
INSTALLATION INSTRUCTIONS
Note to Consumer – Keep these instructions for
future reference.
Ŷ
Skill level – Installation of this vent hood requires
basic mechanical and electrical skills.
Ŷ
Completion time – Approximately 1 to 3 hours
Ŷ
Proper installation is the responsibility of the
installer.
Ŷ
Product failure due to improper installation is not
covered under the Warranty.
CAUTION
these vent hoods and to reduce the risk of personal injury or damage to the product, TWO PEOPLE
ARE REQUIRED FOR PROPER INSTALLATION.
Due to the weight and size of
WARNING
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion
and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
C. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the
outdoors.
E. Turn off breaker to adjacent rooms while
working.
WARNING
USE ONLY METAL DUCT WORK.
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
FOR YOUR SAFETY
WARNING
switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Before beginning the installation,
WARNING
at the main circuit breaker or fuse box before installing.
Disconnect all electrical power
8 49-80816-1
Installation Preparation
INSTALLATION PREPARATION
PRODUCT DIMENSIONS
12-1/4Ǝ
4-5/8Ǝ
25-3/4Ǝ
13-13/16Ǝ
2-3/4Ǝ
30ƎRUƎ
Grease Filters
(quantity may vary
by model)
8Ǝ
12-7/8Ǝ
10-5/8Ǝ
6-15/16Ǝ
INSTALLATION CLEARANCES
These vent hoods are designed to be installed onto a wall with no above cabinets.
24” Required Min.
26-5/8Ǝ min. - 39-1/8Ǝ max.
20Ǝ
The vent hood must be installed between the 24” required minimum and 36” recommended maximum above the cooking surface. For supplied duct cover
ceiling heights, see Installation Height Table.
NOTE: Installation height should be measured from the cooking surface to the lowest part of the hood. The hood must be installed onto a wall. It can be vented to the outdoors, or it can be installed for
20Ǝ
recirculating operation. For recirculation operation, see Recirculation Install Planning.
36” Recommended Max.
30ƎRUƎ
49-80816-1 9
Installation Preparation
TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED)
Safety glasses
Pencil and tape measure
Phillips screwdriver
Level
Wire cutter/stripper
Electric drill with #2 Phillips
and 1/8" drill bits
INSTALLATION PREPARATION
UL listed wire nuts
8" round duct
(length will vary)
Aluminized
duct tape
Strain relief for
junction box
Gloves
REMOVE THE PACKAGING
PLAN THE INSTALLATION
CAUTION
properly exhaust air, be sure to duct the air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
PARTS SUPPLIED FOR INSTALLATION
Ŷ 1 Hardware Package Ŷ 1 Literature Package Ŷ Recirculation Duct (for recirculation install only) Ŷ Charcoal filters (recirculation mode)
PARTS NEEDED FOR INSTALLATION
Ŷ 1 Strain Relief Ŷ 1 Wall or Roof Cap (for ducted venting only) Ŷ All Metal Ductwork (for ducted venting only)
WARNING
PERSONAL INJURY HAZARD
Because of the weight and size of the rangehood canopy. It is recommended that 2 people are used to install the range hood. Failure to properly lift rangehood could result in damage to the product or personal injury.
NOTE: This rangehood can be installed as either ducted or recirculation. In a ducted application, this rangehood can be vented through the wall or ceiling. When installed for recirculation, the rangehood vents out the sides of the duct cover.
NOTE: Before making any cuts or holes for installation, determine which venting method will be used and carefully calculate all measurements.
To reduce risk of fire and to
CAUTION
sharp edges.
Ŷ Remove the duct covers.
Ŷ Remove the hardware bag, literature package
and other boxed parts.
Ŷ Remove and properly discard the protective
plastic wrapping and other packaging materials.
Wear gloves to protect against
10 49-80816-1
Installation Preparation
INSTALLATION PREPARATION
RANGE HOOD COMPONENTS
A. Wall Hood B. Upper Duct Cover C. Lower Duct Cover D. Mounting Screws E. Duct Cover Mounting Bracket F. Damper
J
J
B
C
L
G. Hood Mounting
Bracket H. Mounting Anchors J. Machine Screws K. Recirculation Box L. Wood Screws
J
J
F
J
H
E
D
K
INSTALLATION DIMENSIONS
The Wall Hoods duct covers can be adjusted for different ceiling heights depending on the distance between the bottom of the hood and the cooktop (distance X). See Installation Height Table.
Upper Duct
7/8Ǝ min
H
13-3/8Ǝ max
25-3/4Ǝ
2-3/4Ǝ
X
36”
X = Distance From Hood To
(Varies depending on installation)
Recommended Max - 36”
manufacturer’s recommendation
Cover
Required Min & Recommended
Max Ceiling Height Examples
Lower Duct Cover
Hood Body
Cooktop
Required Min - 24”,
Also consult cooktop
Typical Range
X = 24" X = 36"
Min Min 7' 6" 8' 6" Max Max 8' 6" 9' 5"
Required Min Ceiling
Height for Recirculation
X = 24" X = 36"
Min Min
7' 10" 8' 10"
For higher ceiling installations up to 10', use the 10' High Ceiling Duct Cover kit (UX10DC83) for your model.
For higher ceiling installations up to 12', use the 12' High Ceiling Duct Cover kit (UX12DC93) for your model.
For higher ceiling installations up to 14', use the 14' High Ceiling Duct Cover kit (UX14DC93) for your model.
H
D
G
HARDWARE COMPONENTS
A
J
L
D
RECIRCULATION COMPONENTS
K
49-80816-1 11
NOTE: The chimney extension replaces the upper and lower chimney shipped with the range hood. The hardware included with the hood should be saved and also used with the chimney extension.
L
Phillips Head Wood Screw 3/16" x 1-15/16" (QTY: 4)
Mounting Anchors
H
(QTY: 6)
E
Phillips Head
Mounting Anchors
Screws
3/16" x 1-1/2"
(QTY: 6)
J
Phillips Head Machine Screw 1/8" x 3/8" (QTY: 14)
D
Installation Preparation
INSTALLATION HEIGHT TABLE (UX10DC93SS) (UX12DC93SS) (UX14DC93SS)
Optional High Ceiling Duct
Installation Height with Supplied Duct Covers
Possible
Vented
Ceiling
Height (ft./in.)
7' 6" 24 24 7' 7" 24-25 9' 4" 24-25 12' 24-36 7' 7" 24-25 24-25 7' 8" 24-26 9' 5" 24-26 12' 1" 24-36 7' 8" 24-26 24-26 7' 9" 24-27 9' 6" 24-27 12' 2" 24-36
7' 9" 24-27 24-27 7' 10" 24-28 9' 7" 24-28 12' 3" 24-36 7' 10" 24-28 24-28 24 7' 11" 24-29 9' 8" 24-29 12' 4" 24-36 7' 11" 24-29 24-29 24-25 8' 24-30 9' 9" 24-30 12' 5" 24-36
8' 24-30 24-30 24-26 8' 1" 24-31 9' 10" 24-31 12' 6" 24-36 8' 1" 24-31 24-31 24-27 8' 2" 24-32 9' 11" 24-32 12' 7" 24-36 8' 2" 24-32 24-32 24-28 8' 3" 24-33 10' 24-33 12' 8" 24-36 8' 3" 24-33 25-33 24-29 8' 4" 24-34 10' 1" 24-34 12' 9" 24-36 8' 4" 24-34 26-34 24-30 8' 5" 24-35 10' 2" 24-35 12' 10" 24-36 8' 5" 24-35 27-35 24-31 8' 6"- 9' 5" 24-36 10'3"-11' 24-36 12' 11" 24-36 8' 6" 25-36 28-36 25-32 9' 6" 25-36 11' 1" 24-36 13' 24-36 8' 7" 26-36 29-36 26-33 9' 7" 26-36 11' 2" 24-36 13' 1" 25-36 8' 8" 27-36 30-36 27-34 9' 8" 27-36 11' 3" 24-36 13' 2" 26-36
INSTALLATION PREPARATION
8' 9" 28-36 31-36 28-35 9' 9" 28-36 11' 4" 24-36 13' 3" 27-36
8' 10" 29-36 32-36 29-36 9' 10" 29-36 11' 5" 24-36 13' 4" 28-36 8' 11" 30-36 33-36 30-36 9' 11" 30-36 11' 6" 24-36 13' 5" 29-36
9' 31-36 34-36 31-36 10' 31-36 11' 7" 24-36 13' 6" 30-36 9' 1" 32-36 35-36 32-36 10' 1" 32-36 11' 8" 25-36 13' 7" 31-36 9' 2" 33-36 36 33-36 10' 2" 33-36 11' 9" 26-36 13' 8" 32-36 9' 3" 34-36 34-36 10' 3" 34-36 11' 10" 27-36 13' 9" 33-36 9' 4" 35-36 35-36 10' 4" 35-36 11' 11" 28-36 13' 10" 34-36 9' 5" 36 36 10' 5" 36 12' 29-36 13' 11" 35-36
Possible
Vented Install
Height (in.)
Install Height
(Recirculation
Vented Holes
Hidden) (in.)
For gas range, start chart at 92" and subtract 2" for the maximum install height for each block.
Possible
Recirculation
Install
Height (in.)
Cover up to 10 ft.
(not included with unit)
Ceiling
Height (ft./in.)
7' 6" 24 9' 3" 24 11' 11" 24-36
*Based on a 36" electric range height.
Vented and
Recirculation
Height (in.)
Optional High Ceiling Duct
Cover up to 12 ft.
(not included with unit)
Vented and
Ceiling
Height (ft./in.)
Recirculation
Install
Height (in.)
Optional High Ceiling Duct
Cover up to 14 ft.
(not included with unit)
Ceiling
Height (ft./in.)
14" 36
Vented and
Recirculation
Install
Height (in.)
7/8Ǝ min
25-1/8Ǝ max
25-3/4"
Hood Body
10" High Ceiling Duct Cover Kit
Upper Duct Cover
Lower Duct Cover
7/8Ǝ min
29-7/16" max
46-7/8"
Hood Body
12" High Ceiling Duct Cover Kit
Upper Duct Cover
Lower Duct Cover
Upper Duct Cover
7/8Ǝ min
46-1/4" max
46-7/8"
Lower Duct Cover
Hood Body
14" High Ceiling Duct Cover Kit
12 49-80816-1
Installation Preparation
INSTALLATION PREPARATION
ADVANCE PLANNING
Duct Install Planning
Ŷ This hood is designed to be vented vertically
through the ceiling. Use an 8" round duct. Use locally supplied elbows to vent horizontally through the rear wall.
Ŷ Use metal ductwork only. Ŷ Determine the exact location of the vent hood. Ŷ Plan the route for venting exhaust to the
outdoors. To maximize the ventilation performance of the vent system:
1. Minimize the duct run length and number of transitions and elbows.
2. Maintain a constant duct size.
3. Seal all joints with duct tape to prevent any leaks.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduces performance.
Ŷ Maximum equivalent duct length for 100 CFM:
150 foot for vent hoods.
Ŷ Install a wall cap or roof cap with damper at the
exterior opening. Purchase the wall or roof cap and any transition and length of duct needed in advance.
Ŷ
When applicable, install any makeup (replacement)
air system in accordance with local building code requirements. Use makeup air kit JXMUA8.
Vent system can terminate either through the roof
RUWKHZDOO7RYHQWWKURXJKDZDOOD๦HOERZLV
needed and installed immediately above the hood.
Roof Cap
Add Insulation
and/or Caulk
Round Duct
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Codes or prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
Ŷ Wiring must be 2 wire with ground. Ŷ If the electrical supply does not meet the above
requirements, call a licensed electrician before proceeding.
Ŷ Route house wiring as close to the installation
location as possible in the ceiling or wall.
Ŷ Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood.
WARNING
equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded.
The improper connection of the
Wall Cap
Add tape to joint
Hood
Recirculation Install Planning
A recirculation duct (included) and charcoal filter (included) are necessary for recirculation installation.
Power Supply Planning
The location of the power supply connection is called out in the Installing The Hood Bracket Mount section.
49-80816-1 13
Add Insulation and/or Caulk
Installation
NEW CONSTRUCTION, PRE-PLANNING, OR REMODELING
NOTE: For existing construction, skip to the section, Installing The Hood Bracket Mount.
Ŷ Install horizontal wood supports between 2 wall
studs that align with the vertical mounting height locations shown in the illustration.
Ŷ The horizontal supports must be flush with the room
INSTALLATION
side studs.
Ŷ For ducted installation, the hole for the duct in the
ceiling must be centered 5" away from the finished rear wall.
5"
From the lower left corner of the gray shaded area, it is recommended to have at least 20" of house electrical wiring.
Ŷ The bottom support aligns with the hood mounting
bracket. This height depends on the desired height of the hood.
Ŷ The top support must be flush with the ceiling. Ŷ The electrical wiring can be located 5-1/2” to the left
or right (junction box is on the left) of the centerline. Must remain 7/16” above the back panel and 5” from the ceiling, refer to illustration on next page.
5"
Acceptable
area for
electrical
wiring
14-3/8"
11"
24-36" + 1-1/8"
See the Installation Height Table for possible installation heights.
* 36” or 38” Range
Wood Supports
• 36" minimum width centered
• 4" height
* Typical electrical range is 36"
and typical gas range is 38"
11"
Acceptable area for electrical wiring
14-3/8"
14 49-80816-1
Installation
INSTALLING THE HOOD BRACKET MOUNT
Hood Body
1. Put a protective covering over the surface below the location of the hood to protect from dirt and/or damage.
2. Determine and mark the centerline (C) on the wall (draw line up to the ceiling) where the range hood will be installed. Based on the ceiling height, determine the distance between 24” required min, 36” recommended max (X) needed between the cooking surface (B) and the bottom of the hood. Draw a horizontal line at X. Align the install template so that the bottom of the template is centered and is level with the horizontal line drawn at height X.
Duct Covers and Power Supply
1. Place the duct cover bracket (E) on the wall so that its edge is against the ceiling and level, making sure the slots are in direct contact with the wall. Align the center notches of the bracket and the centerline. Mark the location of the screw holes furthest apart from the center line if possible. If one of the screw holes aligns with a stud, then a wood screw will be used for that location. For the other hole or if there are no studs, install 2 mounting anchors (H). Place the duct cover bracket (E) on the wall and install with wood screws (L) and mounting screws (D) as needed.
2. The house electrical wiring must fall in the gray shaded area shown below. From the lower left corner of the shaded area, a minimum of 20” of house electrical wiring is recommended to reach the electrical junction box on the hood.
INSTALLATION
C
B
1-1/8"
24 to 36"
X
3. Find the stud locations and mark them on the template.
4. Place the hood mounting bracket (G) on its outline on the template. Mark at least one wood screw (L) location that is on a stud. If another stud cannot be found, mark at least two other screw locations for mounting anchors, one on each side of the wood screw (L). Remove the bracket from the wall and install the mounting anchors (H). Place the hood mounting bracket (G) back on the wall and mount it with the wood screws (L) and mounting screws (D) as needed. It is recommended to create a pilot hole in the studs for wood screws (L).
Ceiling
area for house
Acceptable
electrical
wiring
Ǝ%HORZ&HLOLQJ
Ǝ
C
16-7/8"
Mounting
Anchors
Mounting Screw
49-80816-1 15
Wood Screw
Mounting
Screw
Hood Mounting Bracket