General Electric Temp, PB911FJDS, PHB920FJDS, JB645FKDS, PHS930SLSS, JS645SLSS, PS960ELES, PB911EJES, JB700DJBB, JB645RKSS, JB625RKSS Temp
Installation Instructions
2
PREPARE THE OPENING (FOR INDOOR USE ONLY)
Free-Standing and Front
Control Electric Ranges
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT —Save these
instructions for local inspector’s use.
• IMPORTANT — Observe all
governing codes and ordinances.
•Note to Installer – Be sure to leave these
instructions with Consumer.
FOR YOUR SAFETY:
WARNING
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the
range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns
to children or adults.
If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at no
cost. (In Canada, call 1.800.561.3344.) For installation
instructions of the bracket,
visit: www.GEAppliances.com.
(In Canada, www.GEAppliances.ca.)
Tip-Over Hazard
MATERIALS YOU MAY NEED TOOLS YOU WILL NEED
Squeeze Connector
(For Conduit
Installations Only)
REMOVE PACKAGING MATERIALS: Failure to remove packaging
1
materials could result in damage to the appliance. Remove all packing parts from oven,
racks, heating elements and drawer. Also, remove protective film and labels on the outer
door, cooktop and control panel.
(UL Listed 40 AMP)
4-Wire Cord 4’ long OR
3-Wire Cord 4’ long
•Note to Consumer – Keep these
instructions for future reference.
•Skill level – Installation of this appliance
requires basic mechanical skills and
advanced electrical skills.
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation
is not covered under Warranty.
Anti-Tip Bracket
Kit Included
WARNING
the installation, switch power off at
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally.
When the service disconnecting
means cannot be locked, securely
fasten a prominent warning device,
such as a tag, to the service panel.
Drill with 1/8” Bit
Safety Glasses
Adjustable Wrench
Level
Tin Snips
Before beginning
Tape Measure
Pliers
1/4” Nut Driver
See illustrations for all rough-in and spacing dimensions. The range may be placed with 0”
clearance (flush) at the back wall and side walls of the cabinet.
21»2” (31»4” on
Unit will not mount flush
to counter when heights
are less than 36”.
297»8”
NOTE:
Rear wall
to front
of door
glass.
(253»4” on
double oven)
double ovens)
47”
(36” to
cooktop
height)
251»2”
475»8”
1
»8” on
(45
double oven)
Acceptable electrical
outlet area. Orient
electrical receptacle
so the length is
parallel to floor.
Use a flush mount
outlet for double
oven models.
30”
25”
(23” on
double
ovens)
21»2” (31»4” on
double ovens)
6
4” (3”
on double
ovens)
3
(7
»4” on
double
ovens)
1
»2”
297»8”
FRONT CONTROL
297»8”
NOTE:
Rear wall
to front
of door
glass.
253»4”
451»8” (477»8” on
single oven)
365»8”
36”
REAR CONTROL
NOTE: Use a 4’ power cord to prevent interference
with the storage drawer. Power cords 41»2’ to 6’ long
may have to be dressed to allow for proper drawer
closing.
MINIMUM DIMENSIONS BETWEEN COOKTOP,
WALLS AND ABOVE THE COOKTOP:
A. Make sure the wall covering, countertop, flooring
and cabinets around the range can withstand
the heat (up to 200°F) generated by the range.
B. Allow 30” minimum clearance between surface
units and bottom of unprotected wood or metal
cabinet, or allow a 24” minimum when bottom
of wood or metal cabinet is protected by no
less than 1/4” thick flame retardant millboard
covered with not less than No 28 MSG sheet
metal, (.015”), .015” thick stainless steel, .024”
aluminum or .020” copper.
C. This appliance has been approved for 0” spacing to adjacent surfaces above the cooktop.
However, a 6” minimum spacing to surfaces less than 15” above the cooktop and adjacent
cabinet is recommended to reduce exposure to steam, grease splatter and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage
space above the cooktop should be avoided. If cabinet storage space is to be provided above
the cooktop, the risk can be reduced by installing a range hood that projects at least 5” beyond
the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 16”.
NOTE C
A
B
C
Both
Sides
A
ELECTRICAL REQUIREMENTS
3
POWER CORD AND CONDUIT INSTALLATION
4
WARNING
WARNING
where local codes do not allow grounding through neutral, require a 4-conductor UL-listed range
cord.
WARNING
WARNING
installation.
We recommend you have the electrical wiring and hookup of your range connected by a qualified
electrician. After installation, have the electrician show you how to disconnect power from the
range.
You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you
connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring
must be used.
Effective January 1, 1996, the National Electrical Code requires that new construction (not existing)
utilize a 4-conductor connection to an electric range. When installing an electric range in new
construction, mobile home, recreational vehicle, or an area where local codes prohibit grounding
through the neutral conductor, refer to the section on four-conductor branch circuit connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven
according to governing codes could result in a hazardous condition. If there are no local codes,
your oven must be wired and fused to meet the National Electrical Code, NFPA No. 70 – latest
edition, available from the National Fire Protection Association.
This appliance must be supplied with the proper voltage and frequency, and connected to an
individual, properly grounded, 40 amp (minimum) branch circuit protected by a circuit breaker or
time-delay fuse.
Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with
ring terminals on wire and a strain relief device.
A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range
connection openings. Care should be taken to center the cable and strain relief within the knockout
hole to keep the edge from damaging the cable.
The rating plate is located on the oven frame or on the drawer frame.
This appliance must be properly grounded.
All new constructions, mobile homes, recreational vehicles and installations
To prevent fire or shock, do not use an extension cord with this appliance.
To prevent shock, remove house fuse or open circuit breaker before beginning
SINGLE OVEN
DOUBLE OVEN
A. Remove wire cover (on the back of range) by removing screws using a 1/4” nut driver. You can
access the terminal block by either removing a terminal block cover (on some models) or the
wire cover. Do not discard these screws.
Back of range
5 screws
to remove
wire cover
Wire cover
B. For power cord and 1” conduit only, remove the
knockout ring (13»8”) located on bracket directly below
the terminal block. To remove the knockout, use a
pair of pliers to bend the knockout ring away from the
bracket and twist until ring is removed.
C. For power cord installations only (see the next step if
using conduit), assemble the strain relief in the hole.
Insert the power cord through the strain relief and
tighten. Allow enough slack to easily attach the cord
terminals to the terminal block. If tabs are present
at the end of the winged strain relief, they can be
removed for better fit.
NOTE: Do not install the power cord without
a strain relief. The strain relief bracket MUST
be installed before reinstalling the rear range
wiring cover.
D. For 3/4” conduit installations only, purchase a
squeeze connector matching the diameter of
your conduit and assemble it in the hole. Insert
the conduit through the squeeze connector and
tighten. Allow enough slack to easily attach the
wires to the terminal block. NOTE: Do not install the conduit without a squeeze connector.
The squeeze connector MUST be installed before reinstalling the rear range wire or terminal
block cover.
Strain relief
Power cord
Back of range
Screw to
remove
terminal
block cover
Terminal block cover
Terminal block
(appearance
may vary)
Knockout
ring in
bracket
Knockout ring
removed
Terminal
block
Bracket
Rating plate
Rating plate
Squeeze
connector
Conduit
E. Replace wire cover on range back and replace the screws removed earlier. Make sure that
no wires are pinched between cover and range back. Replace the terminal block cover if it was
removed.
PROCEED TO STEP 5 OR 6.
Terminal block
Bracket
5
3-WIRE INSTALLATION
6
4-WIRE INSTALLATION
WARNING
neutral terminal located in the center of the terminal block and the ground strap must connect the
neutral terminal to the ground plate. The power leads must be connected to the lower left and the
lower right terminals of the terminal block.
DO NOT remove the ground strap connection.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower terminal screws from the terminal block.
B. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals
of the terminal block. Be certain that the center wire (white/neutral) is connected to the center
lower position of the terminal block.
C. Tighten screws securely into the terminal block.
FOR CONDUIT INSTALLATION
A. Loosen the 3 lower terminal screws on the terminal block. Strip wire to expose tip about 5/8”
long.
B. Insert the center (white/neutral) wire tip through the bottom center terminal block opening. On
certain models, the wire will need to be inserted through the ground strap opening and then
into the bottom center block opening. Insert the two side bare wire tips into the lower left and
the lower right terminal block openings.
C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the
screws.
NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated for the
correct amperage and voltage.
Power Cord
Terminal block
(appearance
may vary)
Neutral terminal
Ground strap
Ground
plate
Power cord
PROCEED TO STEP 7.
The neutral or ground wire of the power cord must be connected to the
Conduit
Terminal
block
Wire tips
Conduit
WARNING
the supply circuit must be connected to the
neutral terminal located in the lower center of
the terminal block. The power leads must be
connected to the lower left and the lower right
terminals of the terminal block. The grounding
lead must be connected to the frame of the
range with the ground plate and the green
ground screw.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower terminal screws
from the terminal block. Remove the
ground screw and ground plate and retain
them. Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.
B. Insert the one ground screw into the power cord
ground wire terminal ring, through the ground
plate and into the frame of the range.
C. Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and into
the lower terminals of the terminal block. Be
certain that the center wire (white/neutral) is
connected to the center lower position of the
terminal block. Tighten screws securely into the
terminal block.
FOR CONDUIT INSTALLATION
A. Loosen the 3 lower terminal screws on the
terminal block. Strip wire to exposed tip about
5/8” long.
B. Insert the center (white/neutral) wire tip through
the bottom center terminal block opening. On
certain models, the wire will need to be ins
erted through the ground strap opening and
then into the bottom center block opening.
Insert the two side bare wire tips into the lower
left and the lower right terminal block openings.
C. Tighten the screws until the wire is firmly
secured (35 to 50 inch-lbs.). Do not over-tighten
the screws.
NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated for the
correct amperage and voltage.
The neutral wire of
Before–Power Cord and Conduit
Ground strap
Terminal
block
Ground
strap
Neutral
terminal
or
After–Power Cord
Neutral
Terminal
block
Ground
screw
terminal
Ground plate
(grounding to
range)
After–Conduit
Terminal
block
Wire
tips
Ground screw
Ground
plate
(grounding
to range)
31-11105-4 11-18 GEA
Loading...
+ 5 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.