General Electric PSB9240DFBB Specsheet

2x4’s or equivalent solid floor
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4" minimum from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Must Support 150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout. B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Must Support 150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout. B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
C
L
2x4’s or equivalent solid floor
21-5/8"
over centerline
of cabinet
25-1/8"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Construct Solid Bottom Min. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Must Support 150 lbs.)
Conduit
(48-1/2"
long)
19-1/8"
29-3/4"
A=Allow 1" overlap of oven over bottom edge of cutout. B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
PSB9240DF
GE Profile™ Series Advantium® 240V - 30 in. Wall Oven
Advantium wall oven/GE Profile™ Series cooking tower
dimensions and cabinet installation information (in inches)
Note: Cabinets
installed adjacent to wall ovens must have an adhesion spec of at least a 194°F temperature rating.
Note: 2" minimum between cutouts when installed above warming drawer or single wall oven.
Installation Information:
Before installing, consult installation instructions packed with product for current dimensional data.
Note: Advantium 240 volt models cannot be installed under 36 inches height.
Note: Use of the accessory drawer will replace the bottom trim piece for applicable
installations. Please see installation instructions for full details.
Cabinet width
29-3/4"
21-1/2"
To back
of Control
Conduit
(46" long)
19-1/8"
A
B
A
B
4-3/16
Junction box location
2-1/2" MIN between cutouts recommended—2" MIN required
Construct Solid Bottom MIN 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Must Support 150 lbs. for Advantium) (Must Support 200 lbs. for Wall Oven)
9-1/4" cutout height 28-1/2" cutout width
2" MIN between cutouts
For answers to your Monogram® or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
1" Min. above toekick or adjust to oven installation height
(240-volt models only)
Suitable
bracing
to support
runners
C
L
21-5/8"
over centerline
of cabinet
(Must support 130 lbs.)
2x4’s or equivalent solid floor
Specification Revised 3/14
Listed by Underwriters Laboratories
240406
PSB9240DF
Installation over a GE/Monogram Warming Drawer:
recommended)
Warming Drawer:
recommended)
from floor
23-1/2”
2x2
all
GE Profile™ Series Advantium® 240V - 30 in. Wall Oven
Preparation WITH an Accessory Drawer
Prepare the opening
The Advantium 240V can be installed in combination with other GE/Monogram appliances. Always follow each product's Installation Instructions to compete the installation. Single Oven Installation: Order a 30" wide single oven cabinet or cut the opening in a wall to the dimensions shown.
* For existing cutouts, a
maximum width of 28-1/2" is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the oven.
• Always maintain 36-3/4" minimum height from the floor to the cutout in any single or combined installation.
• Allow 3/4" to 2-1/8" case trim overlap on the sides and 7/8" overlap on the bottom of the opening for all models. The amount of overlap on the sides depends on the actual cutout width. Allow 1-1/4" case trim overlap on the top for models PSB9240 and for models ZSC2200, ZSC2201 and ZSC2202.
• Oven overlaps will conceal cut edges on all sides of the opening.
5” min.
from floor
1” min.
above
toekick
30”
21”
25-1/4”
Min.
Construct Base Min. 3/8” Plywood Supported by 2x4 or Runners Four Sides
Prepare the opening (cont.)
When installed over a single oven or a warming drawer, allow at least 2" between the two openings. This separation will provide clearance for bottom overlap of the Advantium 240V and the other appliance overlaps. Construct a solid oven floor of 3/8" min. thick plywood supported by 2 x 4 or 2 x 2 runners on all sides.
• the support must be level and rigidly mounted, flush with the bottom edge of the cutout.
5” min.
from floor
1” min. above toekick
30”
21”
23-1/2”
25-1/4”
Min.
Construct Solid Bottom Min. 3/8” Plywood Supported by 2x4 or 2x2 Runners all Four Sides
2” Min. (3”
Per warming drawer requirement
Installation over a GE/Monogram Oven and Warming Drawer:
Construct Solid
30”
21”
5” min.
1” min.
Per warming drawer requirement
above
toekick
23-1/2”
25-1/4”
Min.
Bottom Min. 3/8” Plywood Supported by 2x4 or 2x2 Runners all Four Sides
2” Min. (3”
Per Oven Requirement
2” Min.
* For existing cutouts, a maximum width of
28-1/2" is acceptable. If the opening is slightly wider, secure a furring strip on each side of
the cutout for securing the oven. Note: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details. CAUTION: For personal safety, the mounting surface must be capable of supporting the
* For existing cutouts, a maximum width of
28-1/2" is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the oven.
cabinet load, in addition to the added weight of this approximate 80-pound oven and 30­pound drawer, plus additional oven loads of up to 50 pounds or a total weight of 160 pounds.
Note: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details.
Specification Revised 3/14
240406
Loading...