PP9830DJ/TJ
29 3/4"
(29 13/16" SS)
28 3/4"
21 7/8"
(21 15/16" SS)
2 3/16"
(2 1/4" SS)
22"
20 1/2"
11 1/2"
Cut-out Dimensions (in inches)
GE Profile
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
™
Series 30" Downdraft Electric Cooktop
WALL INSTALLATION: Wall installations require
25" countertop depth. When cabinet is flush against
the wall, the fan housing can be rotated to the
horizontal position for direct venting through rear
wall. Make a countertop cutout in the range cabinet
according to unit dimensions and installation type.
Duct hole is positioned in back of cabinet for
through-the-wall ducting.
PENINSULA OR ISLAND INSTALLATION: For
peninsula/islands a minimum 26" countertop depth is
suggested. Blower should be in vertical position. Island
or peninsula cabinets may require adjustment in cutout
depth and/or location within the width dimensions.
Duct hole is positioned in bottom of cabinet for island
or peninsula installation.
SLAB INSTALLATION: For peninsula or island
installation and rear wall ducting, 6" PVC duct or
locally approved piping should be used if installing
under a poured concrete slab.
RECEPTAC L E LOCATION: Install an approved
junction box within shaded area shown in diagram.
Junction box must be at least 10-1/2" below top
of cabinet.
INSTALLATION I N FORMATI O N : Before installing,
consult installation instructions, packed with product,
for current dimensional data.
NOTE: Electrical cable is not supplied with unit.
Order part number JXCK89 from your Ge Appliances Dealer
These cooktops are approved for indoor use only.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
APPROXIMATE COOKING DIMENSIONS
(21 15/16" SS)
20 5/8"
25"
1 7/8"
MIN. Required*
*U.L. Requirement
Note: A 5" minimum spacing to adjacent side wall is required
KW R ATI N G
240V 9.1
208V 6.9
(29 13/16" SS)
22"
22"
11 1/2"
20 1/2"
20 1/2"
28 7/8"
11 1/2"
28 3/4"
28 3/4"
9
C
L
4
16
20
*Note: A 6" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
Specification Revised 1/19
2 3/16"
(2 1/4" SS)
10-1/2
Listed by
Underwriters
Laboratories

PP9830DJ/TJ
Inside Wall to Roof Direct to Outside
GE Profile
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
INSTALLING THE DUCTWORK: Use
galvanized or aluminum duct in 6" round
or 3-1/4" x 10" size, or combination of
both. PVC duct or locally approved
piping should be used if installing under
a poured concrete slab. Local building
code must be followed in specifying type
and schedule of all duct used.
NOTE: Ductwork must be vented to
outside. Do not vent into a wall, ceiling,
crawlspace, attic or any concealed space.
Always use an appropriate roof or wall
cap with damper.
Laundry-type wall caps should never
be used. For maximum efficiency use
the shortest and straightest duct run
possible, with as few fittings as possible.
For satisfactory performance the
duct run should not exceed 100
feet equivalent length. Refer to the
table of equivalent lengths (shown in
installation instructions) for various duct
configurations.
™
Series 30" Downdraft Electric Cooktop
Through Cabinet Toe Space
10-1/8
Between Floor Joist
6-1/8
9-1/8
18-3/4
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Rear Wall VentingDownward Venting
Listed by
Underwriters
Laboratories
Specification Revised 1/19